ÀÓÇöõÆ®ÀÇ ³ª»ç µðÀÚÀÎ, ÇØ¸é°ñÀÇ °ñÁú, ±×¸®°í ÇÇÁú°ñÀÇ µÎ²²°¡ Ãʱ⠾ÈÁ¤µµ¿¡ ¹ÌÄ¡´Â ¿µÇâ
Effect of thread design, trabecular density, and cortical thickness on the primary stability of implant
Çö±â, ±è¹Î¼®, ±è¿µ°¢, Ȳ¼®Çö, ±èÀ縸, ÁÖÃÑ, ÃÖ¿¬Á¶, Àü»óÈ£, ·ùÀçÁØ, ±ÇÁ¾Áø,
¼Ò¼Ó »ó¼¼Á¤º¸
Çö±â ( Hyun Ki ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
±è¹Î¼® ( Kim Min-Suk ) - °í·Á´ëÇб³ ÀÓ»óÄ¡ÀÇÇдëÇпø
±è¿µ°¢ ( Kim Young-Kak ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
Ȳ¼®Çö ( Hwang Suk-Hyun ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
±èÀ縸 ( Kim Jae-Man ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
ÁÖÃÑ ( Zhou Cong ) - °í·Á´ëÇб³ ÀÓ»óÄ¡ÀÇÇдëÇпø
ÃÖ¿¬Á¶ ( Choi Yeon-Jo ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú º¸Ã¶°ú
Àü»óÈ£ ( Jun Sang-Ho ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
·ùÀçÁØ ( Ryu Jae-Jun ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú º¸Ã¶°ú
±ÇÁ¾Áø ( Kwon Jong-Jin ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú ±¸°¾Ç¾È¸é¿Ü°ú
KMID : 1025720130320010011
Abstract
Purpose: The purpose of study was to analyze the influence on the implant design, density of cancellous bone and thickness of cortical bone to the implant primary stability.
Materials and Methods: A total of 144 implants (4.0¡¿10 mm) were installed in 24 artificial bones. Implants were divided into 3 groups. Artificial bones were divided into 4 groups.
Results: There was statistical significance among ITV, ISQ, PTV (p£¼0.05). Element that effects to primary stability, D3 bone has been above D4 bone. Primary stability has been influenced according to existence of cortical bone and has shown a great level as cortical bone is 2 mm. The B implant has shown the highest primary stability level among the three types of Implants: macro thread £¾ double micro, macro and micro thread £¾ macro and micro thread. The degrees of the factors affecting primary stability: implant fixture£¾ cortical bone£¾cancellous bone type.
Conclusions: There has been a close correlation among the results of three stability measuring devices (ITV, ISQ, PTV). The fixture types of Implant have been the biggest influences to primary stability among all the factors.
Ű¿öµå
Primary stability; Artificial bones; Thread design; Trabecular density; Cortical thickness
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸