Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¾ç±Ø ¹þ±è Àü¾ÐÀü·ù¹ý (Anodic stripping voltammetry: ASV)À» ÀÌ¿ëÇÑ ÀÎü Ÿ¾× ³» ³³°ú Ä«µå¹ÅÀÇ °ËÃâ

Electrochemical Detection of Lead and Cadmium in Human Saliva by Anodic Stripping Voltammetry (ASV) Analysis: A Pilot Study

´ëÇѱ¸°­³»°úÇÐȸÁö 2007³â 32±Ç 4È£ p.347 ~ 355
±è¿µÁØ, ±èö,
¼Ò¼Ó »ó¼¼Á¤º¸
±è¿µÁØ ( Kim Young-Jun ) - °­¸ª´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­³»°úÁø´ÜÇб³½Ç
±èö ( Kim Cheol ) - °­¸ª´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­³»°úÁø´ÜÇб³½Ç

Abstract

º» ¿¬±¸´Â, ¾ç±Ø ¹þ±è Àü¾ÐÀü·ù¹ý (Anodic stripping voltammetry: ASV)À» ÀÌ¿ëÇÏ¿©, Àüó¸® °úÁ¤ (pre-treatment procedure)¿¡ µû¸¥ ÀÎü Ÿ¾×³» ³³ (Pb)°ú Ä«µå¹Å (Cd)ÀÇ °ËÃâ³óµµÀÇ Â÷À̸¦ ºñ±³Çϱâ À§ÇÏ¿© ½ÃÇàµÇ¾ú´Ù. ³³°ú Ä«µå¹Å¿¡ ³ëÃâµÇÁö ¾ÊÀ» °ÍÀ¸·Î ÃßÁ¤µÇ´Â ³²³à 10¸íÀ» ´ë»óÀ¸·Î, ºñÀڱؼº ÀüŸ¾×À» äÃëÇÑ ÈÄ, °¢ ½Ã·á¸¦ 6°³ÀÇ ½ÃÆíÀ¸·Î ³ª´©¾î¼­ ¿ø½ÉºÐ¸®¸¦ ½ÃÇàÇÑ ÈÄ 3°¡Áö Àü󸮸¦ ÇÏ´Â °æ¿ì¿Í ¿ø½ÉºÐ¸®¸¦ ½ÃÇàÇÏÁö ¾Ê°í 3°¡Áö Àü󸮸¦ ÇÏ´Â °æ¿ì·Î ±¸ºÐÇÏ¿´´Ù. Ÿ¾×ÀÇ Àü󸮹ýÀº simple dilution by electrolyte, simple dilution by HCl, acid digestion by nitric acid µî 3°¡Áö¸¦ °¢°¢ ½ÃÇàÇßÀ¸¸ç, ASV¹ýÀ¸·Î Ÿ¾× ³» ³³°ú Ä«µå¹ÅÀÇ ³óµµ¸¦ ºÐ¼®ÇÏ¿´´Ù. ½ÇÇè°á°ú´Â ´ÙÀ½°ú °°´Ù.
1. ¡®Å¸¾× ½Ã·áÀÇ Àüó¸® ¹æ¹ý¿¡ µû¸¥ Ÿ¾×³» ³³ÀÇ Æò±Õ ³óµµ¡¯¸¦ »ìÆ캸¸é, ¿ø½ÉºÐ¸® ½ÃÇ౺ÀÌ ¿ø½ÉºÐ¸® ¹Ì½ÃÇ౺¿¡ ºñÇÏ¿© Æò±Õ³óµµ°¡ À¯ÀǼº ÀÖ°Ô ³ô¾Ò´Ù.
2. Ÿ¾×³» ³³ÀÇ °ËÃâ¿¡ À־, ´Ü¼øÈ÷ ÀüÇØÁú·Î Èñ¼®¸¸ ÇÑ °æ¿ìº¸´Ù ¿°»êÀ̳ª Áú»êÀ¸·Î Àü󸮸¦ ½ÃÇàÇÑ °æ¿ì¿¡ À¯ÀǼº ÀÖ°Ô ´õ ³ôÀº ³óµµ¸¦ ³ªÅ¸³»¾ú´Ù.
3. ¡®Å¸¾× ½Ã·áÀÇ Àüó¸® ¹æ¹ý¿¡ µû¸¥ Ÿ¾×³» Ä«µå¹ÅÀÇ Æò±Õ ³óµµ¡¯¸¦ »ìÆ캸¸é, ¿ø½ÉºÐ¸® ½ÃÇ౺ÀÌ ¿ø½ÉºÐ¸® ¹Ì½ÃÇ౺¿¡ ºñÇÏ¿© Æò±Õ³óµµ°¡ À¯ÀǼº ÀÖ°Ô ³ô¾Ò´Ù.
4. Ÿ¾×³» Ä«µå¹ÅÀÇ °ËÃâ¿¡ À־, ´Ü¼øÈ÷ ÀüÇØÁú·Î Èñ¼®¸¸ ÇÑ °æ¿ìº¸´Ù ¿°»êÀ̳ª Áú»êÀ¸·Î Àü󸮸¦ ½ÃÇàÇÑ °æ¿ì°¡ ´õ ³ôÀº ³óµµ¸¦ ³ªÅ¸³»¾úÀ¸³ª, À¯ÀÇÇÑ Â÷ÀÌ´Â ¾Æ´Ï¾ú´Ù.

The aim of this study was to evaluate the differences of salivary lead (Pb) and cadmium (Cd) concentrations, using ASV analysis, after various pre-treatment procedures. 10 unstimulated whole saliva samples of non-exposed subjects to Pb and Cd were collected. Each sample was divided into 6 aliquots and centrifugation was performed in only 3 aliquots. After centrifugation, 3 different types of pre-treatment procedures were carried out. Also, these pre-treatment procedures were carried out for another 3 aliquots, without centrifugation. Pre-treated aliquots were analyzed electrochemically, by ASV. The results are as follows:
1. Mean concentration of Pb in saliva after centrifugation was significantly higher than that of non-centrifugation.
2. In the detection sensitivity of Pb in saliva, those of simple dilution technique by HCl and acid digestion technique by nitric acid were significantly higher than that of simple dilution technique by electrolyte.
3. Mean concentration of Cd in saliva after centrifugation was significantly higher than that of non-centrifugation.
4. In the detection sensitivity of Cd in saliva, those of simple dilution technique by HCl and acid digestion technique by nitric acid were higher than that of simple dilution technique by electrolyte. But, there were no significant differences between them.

Å°¿öµå

¾ç±Ø ¹þ±è Àü¾ÐÀü·ù¹ý(Anodic stripping voltammetry: ASV);ÀÎü Ÿ¾×;³³;Ä«µå¹Å;Àüó¸®(pre-treatment)
human saliva;lead;cadmium

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI