Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ä¡°ú¿ë ÀÓÇÁ¶õÆ®¸¦ ÀÌ¿ëÇÑ Ä¡¾Æȸº¹¿¡ °üÇÑ ÀÓ»óÀû Æò°¡

CLINICAL EVALUATION ON THE MOUTH REHABILITATION USING DENTAL IMPLANTS

´ëÇѱ¸°­¾Ç¾È¸é¿Ü°úÇÐȸÁö 1997³â 23±Ç 4È£ p.736 ~ 748
¼Ò¼Ó »ó¼¼Á¤º¸
Áö¿µ´ö/Young-Duck Jee ÃÖ±Ôȯ/¹Îº¹±â/½É¿øº¸/À̵¿±Ù/Kyu-Hwan Choi/Bok-Gi Min/Won-Bo Shim/Dong-Keun Lee

Abstract

°á·Ð
1993³â 3¿ùºÎÅÍ 1996³â 12¿ù±îÁö Çѱ¹º¸Èƺ´¿øÄ¡°ú¿¡ ³»¿øÇÏ¿© ÀÓÇÁ¶õÆ® ¸Å½ÄÀ» ½ÃÇàÇÑ
159¸íÀÇ È¯ÀÚ¸¦ ´ë»óÀ¸·Î ȯÀÚÀÇ ³ªÀÌ, ¼ºº°, ¸Å½ÄÇÑ ÀÓÇÁ¶õÆ®ÀÇ Á¾·ù, ¸Å½Ä À§Ä¡, ½ÇÆÐÇÑ ÀÓ
ÇÁ¶õÆ®ÀÇ ¼ö¸¦ Á¶»çÇÏ¿´À¸¸ç ¼úÈÄ Ä¡¾Æ ȸº¹¿¡ ±â´ÉÀû, ½É¹ÌÀû ÀÓ»ó Æò°¡¸¦ ÇÏ¿© ´ÙÀ½°ú °°
Àº °á·ÐÀ» ¾ò¾ú´Ù.
1. ÀÓÇÁ¶õÆ®¸¦ ¸Å½ÄÇÑ È¯ÀÚ´Â ³²ÀÚ 129¸í, ¿©ÀÚ 30¸í ÃÑ 159¸íÀÇ È¯ÀÚ Áß 60´ëÀÇ È¯ÀÚ°¡
67¸íÀ¸·Î °¡Àå ¸¹¾Ò°í 50´ëÀÇ È¯ÀÚ°¡ 37¸íÀ̾úÀ¸¸ç »ó¾Ç 42¸í, ÇÏ¾Ç 117¸íÀ¸·Î ÇϾÇÀÌ 3¹è
Á¤µµ ´õ ¸¹¾Ò´Ù.
2. °ñÁú¿¡ À־ 2, 3±ÞÀÌ °¡Àå ¸¹¾ÒÀ¸¸ç °ñ¾çÀº B, CÇüÀÌ °¡Àå ¸¹¾Ò´Ù. 159¸íÀÇ È¯ÀÚÁß
92¸íÀÌ BÇüÀ̾úÀ¸¸ç 98¸íÀÌ 2±ÞÀ̾ú´Ù. BÇü°ú, 2±ÞÀ» ÇÔ²² º¸À̴ ȯÀÚ´Â 54¸íÀ̾ú´Ù.
3. ÃÑ 503°³ÀÇ ÀÓÇÁ¶õÆ®¸¦ ¸Å½ÄÇÏ¿´°í ÀÌÁß 41°³ÀÇ ÀÓÇÁ¶õÆ®°¡ °ñÀ¯Âø¿¡ ½ÇÆÐÇÏ¿© Á¦°Å
µÇ¾ú´Ù. Á¦°Å ½Ã±â¸¦ º¸¸é 1Â÷ ¼ö¼ú ÈÄ 2Â÷ ¼ö¼ú Àü±îÁö 15°³, 2Â÷ ¼ö¼ú ÈÄ º¸Ã¶¹° ÀåÂøÀü±î
Áö 5°³, º¸Ã¶¹° ¿Ï¼º ÈÄ 21°³ÀÇ ÀÓÇÁ¶õÆ®°¡ Á¦°ÅµÇ¾ú´Ù. Steri-oss threaded ÀÓÇÁ¶õÆ®´Â 92%
ÀÇ ¼º°ø·üÀ» º¸¿´°í, Steri-oss threaded with HA coated·Î ÀÓÇÁ¶õÆ®´Â 91%, Steri-oss
cylinder with HA coatedµÈ ÀÓÇÁ¶õÆ®´Â 90%ÀÇ ¼º°øÀ²À» º¸¿´À¸¸ç, Integral cylinder with
HA coactedµÈ ÀÓÇÁ¶õÆ®´Â 90%ÀÇ ¼º°øÀ²À» º¸¿´°í 3i typeÀº 93%ÀÇ ¼º°øÀ²À» º¸¿´´Ù. Àüü
ÀûÀ¸·Î 92%ÀÇ ¼º°øÀ²À» º¸¿´´Ù.
4. ȯÀÚÀÇ ¸¸Á·µµ´Â ±â´ÉÀûÀÎ ¸é¿¡¼­ ¾ÆÁÖ ¸¸Á·(62%)·Î ³ªÅ¸³µ°í ½É¹ÌÀûÀÎ ¸é¿¡¼­´Â ¾ÆÁÖ
¸¸Á·(85%)À̾ú´Ù.
#ÃÊ·Ï#
The use of osseointegrated implants is an accepted procedure for the treatment of
Total, or partial edentulism and offers good predictability of long-term success.
Osseointegration implies a firm and direct interlocking between vital bone and
screw-shaped titanium implants. There should be not to interposed tissue between
fixture and bone.
This study was undertaken to assess the clinical condition, complication, and
prosthodontic aftercare of different implant systems. One hundred fifty-nine patients
treated with a total of 503 endosseous implants (364 Steri-oss threaded type, 69 Integral
cylinder with HA coated type, 35 Steri-oss threaded with HA coated type, 21 Steri-oss
cylinder with HA coated type and 14 3i implant type), Most of the implant were placed
in type B and C bone quantity and type 2 and 3 bone quality according to Lekhorm and
Zarb. The success rate of Steri-oss threaded type during healing and function was 92%,
Steri-oss threaded type with hydroxyapatite coated was 91%, Steri-oss cylinder type
with hydroxyapatite coated was 90%, Integral cylinder type with hydroxyapatite coated
was 90% and 3i implant type was 93%.
One hundred twenty-nine patients had been treated with implant prosthesis. 79 of
these patients had received a fixed type prosthesis and 50 patients had received a
removable type prosthesis. There were no differences between the implant systems with
regard to age, gender. Failures were associated with poor bone quality, smaller implant
sizes, a surgical installation technique and stress distribution when in function.
Visual analgoue scales recorded as satisfied results functionally and esthetically, but
15% dissatified with chewing ability.

Å°¿öµå

Dental Implants; clinical evaluation; prosthodontic aftercare;

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed