Àü¿ÏÇÇÆÇÀÇ °ø¿©ºÎ ÇÕº´ÁõÀ¸·Î¼­ °Ç³ëÃâ¿¡ ÆÇÇÑ Áõ·Êº¸°í

TENDON EXPOSURE AS A FOREARM FLAP DONOR SITE COMPLICATION ; A CASE REPORT

´ëÇѱ¸°­¾Ç¾È¸é¿Ü°úÇÐȸÁö 1998³â 24±Ç 1È£ p.153 ~ 155
ÃÖº´È£, À¯ÀçÇÏ, Á¤ÀçÇü, Á¤ÀçÈ£,
¼Ò¼Ó »ó¼¼Á¤º¸
ÃÖº´È£ (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
À¯ÀçÇÏ (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
Á¤ÀçÇü (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
Á¤ÀçÈ£ (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç

Abstract

Àü¿ÏÇÇÆÇÀÇ °ø¿©ºÎÀ§¸¦ ÇǺÎÀ̽ÄÀ¸·Î ÇÇ°³ÇÏ¿´À¸³ª °Ç³ëÃâÀÌ ¹ß»ýÇÒ °æ¿ì ±¹¼ÒÇÇÆÇÀ¸·Î
°Ç³ëÃâ ºÎÀ§ÀÇ ÇÇ°³°¡ ¾î·Á¿ì¸é ÇǺÎÀçÀ̽ÄÀ» ½ÃÇàÇÏÁö ¾Ê°í Àγ»¸¦ °¡Áö°í ÀÌÂ÷ÀûÀÎ »óÇÇ
È­ ¹æ¹ýÀ» ¼±ÅÃÇÏ´Â °ÍÀÌ Ä¡·á±â°£ÀÇ ´ÜÃà°ú ȯÀÚÀÇ ºÒÆí°¨¼Ò¿¡ Å« µµ¿òÀÌ µÉ °ÍÀ¸·Î »ý°¢
µÈ´Ù.
#ÃÊ·Ï#
Forearm flap has been widely used in reconstruction of the head and neck region
because of its outstanding good qualities : thin skin, a small quantity of fat tissue, long
vascular stem, wide lumen of arteria radialis, and the choice of more veins for
anastomosis. After flap elevation, donor site is mostly covered by skin graft. But donor
site complication has been frequently reported. A rate of tendon exposure, one of the
most common complication, ranges from 6.7% to 53%. Improper treatment of tendon
exposure may result in severe scarring and limitation of wrist motion.
We experienced a tendon exposure in a patient who diagnosed oral cancer and
underwent wide excision of lesion and reconstruction by use of radial forearm flap. Our
experience in the treatment of the tendon exposure is presented.