Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

µµÀç½ÃÆíÀ» Åõ°úÇÑ °¡½Ã±¤¼±ÀÌ º¹ÇÕ·¹Áø ÁßÇÕ¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ °üÇÑ ½ÇÇèÀû ¿¬±¸

AN EXPERIMENTAL STUDY ON THE EFFECT OF THE VISIBLE LIGHT THROUGH THE PORCELAIN DISC ON THE CURING OF THE COMPOSITE RESIN

´ëÇѼҾÆÄ¡°úÇÐȸÁö 1991³â 18±Ç 1È£ p.173 ~ 183
ÀÌÁ¦È£, Á¤Àç¿ë,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌÁ¦È£ (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°ú¹æ»ç¼±Çб³½Ç
Á¤Àç¿ë (  ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç

Abstract

°á ·Ð
Porecelain laminate disc¸¦ Åë°úÇÑ ºûÀÇ Á¶»ç½Ã°£ÀÌ º¹ÇÕ·¹ÁøÀÇ ÁßÇÕ¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» Æò
°¡Çϱâ À§ÇØ °¡½Ã±¤¼± ÁßÇÕÇü hybrid º¹ÇÕ·¹ÁøÀÎ CHOICE¸¦ »ç¿ëÇÏ¿© ½ÃÆíÀÇ ³ôÀ̸¦ lmm,
2mm, 3mm·Î ÇÏ°í µµÀç½ÃÆíÀÇ µÎ²²¸¦ 0.5mm, 1mm·Î ÇÑ ÈÄ °¡½Ã±¤¼±À» 30ÃÊ, 60ÃÊ, 90ÃÊ
Á¶»çÇÏ¿© °¢ Á¶ÇÕ¸¶´Ù 3°³ÀÇ ½ÃÆí¾¿ ÃÑ 81°³ º¹ÇÕ·¹Áø ½ÃÆíÀÇ »óºÎ¸é°ú ÇϺθéÀÇ Ç¥¸é°æµµ
¸¦ ÃøÁ¤ÇÑ °á°ú ´ÙÀ½ÀÇ °á·ÐÀ» ¾ò¾ú´Ù.
1. µµÀç´Â °¡½Ã±¤¼±ÀÇ Åõ°ú¸¦ ÀúÇØÇÏ¸ç µµÀçÀÇ µÎ²²°¡ Áõ°¡ÇÒ¼ö·Ï º¹ÇÕ·¹ÁøÀÇ Ç¥¸é°æµµ ¹×
ÁßÇÕ±íÀÌ´Â À¯ÀǼºÀÖ°Ô °¨¼ÒÇÏ¿´´Ù.
2. °¡½Ã±¤¼±ÀÇ Á¶»ç½Ã°£ÀÌ Áõ°¡ÇÒ¼ö·Ï º¹ÇÕ·¹ÁøÀÇ Ç¥¸é°æµµ ¹× ÁßÇÕ±íÀÌ´Â À¯ÀǼºÀÖ°Ô Áõ
°¡ÇÏ¿´´Ù.
3. °¡½Ã±¤¼±À» 90ÃÊ°£ Á¶»çÇÏ¿©µµ ¸ðµç ±º¿¡¼­ Ç¥¸éÀ¸·ÎºÎÅÍ 3mm±íÀÌÀÇ º¹ÇÕ·¹ÁøÀº ÁßÇÕ
µÇÁö ¾Ê¾Ò´Ù.
4. º¹ÇÕ·¹ÁøÀÇ Ç¥¸é°æµµ¿Í 1mmÇϺÎÀÇ °æµµÂ÷ÀÌ´Â ±¤¼±Á¶»ç½Ã°£ÀÌ Áß°¡ÇÒ¼ö·Ï °¨¼ÒÇÏ¿´´Ù.
5. ÀÓ»ó¿¡¼­ Porcelain laminate veneer¼ú½Ä ½ÃÇà½Ã º¹ÇÕ·¹ÁøÀÇ ÃæºÐÇÑ ÁßÇÕÀ» ¾ò±â À§Çؼ­
´Â ÃÖ¼Ò 90ÃÊÀÌ»óÀÇ °¡½Ã±¤¼± Á¶»ç°¡ ÇÊ¿äÇÒ °ÍÀ¸·Î »ç·áµÈ´Ù.
#ÃÊ·Ï#
The purpose of this study was to evaluate the effect of the of the visible through the
porcelain disc on the curing of the composite resin.
Round porcelain discs 10 mm in diameter were processed in two thicknesses ; 0.5 mm
and 1 mm, and black plastic molds 6.5 mm in inner diameter were prepared in three
heights ; 1 mm, 2 mm and 3 mm.
A mold was placed on the glass plate and pressure filled with composite resin ( hybrid
type CHOICE porcelain adhesive paste, shade A1, Bisco Dental Product Co. ).
In experimental group, a celluloid strip was placed over the composite resin and a
porcelain disc was placed on the top. The composite resin specimens were cured with
visible light curing unit using exposure time of 30, 60 and 90 seconds.
In control group, only celluloid strip was placed over the composite resin and cured
with visible light curing unit using given three different exposure time.
The variables of the porcelain disc thickness, the exposure time and specimen height
produced total 81 specimens.
After the visible light exposed, the surface Knoop hardness number of each composite
resin specimen was measured on both sides(top and bottom).
Results of this study were as follows ;
1. The porcelain disc diminished the degree of the visible light transmission and as the
thickness of porcelain disc increased, the surface hardness and curing depth of the
composite resin specimen decreased with statistical significance.
2. As the exposure time of the visible light increased, the surface hardness and curing
depth of the composite resin specimen increased with statistical significance.
3. Even though the exposure time of the visible light was 90 seconds, the bottom
surface of 3 mm height composite resin specimen was not cured.
4. As the exposure time of the visible light increased, the difference of top surface
hardness and 1 mm bottom surface hardness was reduced.
5. In clinical situation of the porcelain laminate technique, it is supposed that at least
90 seconds of visible light exposure time is necessary to obtain the adequate curing of
the composite resin.

Å°¿öµå

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI