Pulsed Nd : YAG ·¹ÀÌÀúÀÇ Ä¡¼ö¸¶ÃëÈ¿°ú¿¡ °üÇÑ ¿¬±¸

A STUDY OF ANALGESIC EFFECT ON PULP INDUCED BY PULSED Nd : YAG LASER

´ëÇѼҾÆÄ¡°úÇÐȸÁö 1997³â 24±Ç 1È£ p.301 ~ 312
±èµµÇü, ¹Ú½½Èñ, ÀÓ»ó¼ö,
¼Ò¼Ó »ó¼¼Á¤º¸
±èµµÇü (  ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç
¹Ú½½Èñ (  ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç
ÀÓ»ó¼ö (  ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç

Abstract

°á·Ð
ÀÌ¿Í°°ÀÌ ÇöÀç±îÁö ·¹ÀÌÀú Á¶»çÈÄ Ä¡¼ö¸¶ÃëÀ¯µµ¿¡ °üÇÑ Á¤È®ÇÑ ±âÀüÀº ¾Ë·ÁÁöÁö ¾Ê¾ÒÁö¸¸
·¹ÀÌÀú Á¶»ç ÈÄ¿¡´Â ÀϹÝÀûÀÎ ±¹¼Ò¸¶Ãë½ÃÀÇ µ¿ÅëÀ̳ª ¸¶ÃëÈÄÀÇ ºÒÆí°¨, °¨¿° °¡´É¼º µîÀÇ
À¯¹ß¾øÀÌ ¿¬Á¶Á÷ óġ³ª º¸Á¸ÀûÀÎ Ä¡·á¸¦ ½ÃÇàÇÒ ¼ö ÀÖ´Ù°í »ç·áµÇ³ª ÇöÀç Ä¡°úÀÓ»ó°¡¿¡ ÀÇ
ÇØ º¸°íµÇ¾î Áö°í ÀÖ´Â Pulsed Nd : YAG ·¹ÀÌÀúÀÇ Ä¡¼ö¸¶ÃëÀ¯µµ ¼ú½ÄÀº °¢±â ´Ù¸¥ Ãâ·Â°ú
Á¶»ç¹æ¹ý µîÀ» »ç¿ëÇÏ°í ÀÖÀ¸¹Ç·Î, ÀÓ»óÀûÀ¸·Î ÀÌ¿ëÇϱ⿡ ÃæºÐÇÏ°í °´°üÀûÀÎ ÀÚ·á°¡ ¹Ìºñ
ÇÏ´Ù°í »ç·áµÇ´Â ¹Ù º» ¿¬±¸´Â ´Ù¾çÇÑ Ãâ·Â°ú Á¶»ç½Ã°£, Á¶»ç¹æ¹ý¿¡ µû¸¥ Ä¡¼öÀÇ µ¿Å뿪ġ
ÀÇ »ó½ÂÈ¿°ú¿Í Ä¡¼ö¸¶ÃëÀÇ Áö¼Ó½Ã°£À» Æò°¡Çϱâ À§ÇØ Ä¡¼ö¿¡ ÀÚ±ØÀÌ ¿ªÄ¡¿¡ µµ´ÞÇÒ ¶§±îÁö
Àü·ù¸¦ º¯È­½ÃÄÑ Ä¡¾Æ°¡ ÀÌ¿¡ ¹ÝÀÀÇÏ´ÂÁö ¿©ºÎ¸¦ °Ë»çÇϱâ À§ÇØ °í¾ÈµÈ Ä¡¼öÀü±â°Ë»ç±â¸¦
ÀÌ¿ëÇÏ¿© ·¹ÀÌÀú Á¶»çÀü°ú ÈÄÀÇ Ä¡¼öÀü±â°Ë»ç¹ÝÀÀ¼öÄ¡¸¦ ÃøÁ¤ÇÏ¿© ·¹ÀÌÀú Á¶»ç¿¡ µû¸¥ Ä¡¼ö
ÀÇ µ¿Åë ¿ªÄ¡ »ó½ÂÈ¿°ú¸¦ ÆÇ´ÜÇÏ¿´À¸¸ç, ·¹ÀÌÀú¸¦ ÀÌ¿ëÇÑ Ä¡¼öÀÇ ¸¶Ãë À¯µµ¸¦ Æò°¡Çϱâ À§
ÇØ °ÇÀüÇÑ »óÇÏ¾Ç °ßÄ¡¸¦ ¸ðµÎ °¡Áö°í ÀÖ´Â Á¶¼±´ëÇб³ Ä¡°ú´ëÇп¡ ÀçÇÐÁßÀÎ Çлý 90¸í Áß
·¹ÀÌÀúÀÇ Ãâ·Â°ú Àû¿ë½Ã°£¿¡ µû¸¥ µ¿Åë¾ïÁ¦È¿°ú¸¦ ºñ±³Çϱâ À§ÇØ 60¸í(ºñÁ¢ÃË ¹æ½Ä : 30¸í,
Á¢ÃË ¹æ½Ä : 30¸í)À» ´ë»óÀ¸·Î »ó¾Ç ¿ìÃø °ßÄ¡¿¡ 1.5W 15Hz·Î 1ºÐ 30Ãʵ¿¾È Á¶»çÇÑ °æ¿ì¸¦
Á¦ I±º, »ó¾Ç ÁÂÃø °ßÄ¡¿¡ 3W 30Hz·Î 1ºÐ 30Ãʵ¿¾È Á¶»çÇÑ °æ¿ì¸¦ Á¦ ¥±±º, ÇÏ¾Ç ¿ìÃø °ß
Ä¡¿¡ 1.5W 15Hz·Î 3ºÐ°£ Á¶»çÇÑ °æ¿ì¸¦ Á¦ ¥²±º, ÇÏ¾Ç ÁÂÃø °ßÄ¡¿¡ 3W 30Hz·Î 3ºÐ°£ Á¶
»çÇÑ °æ¿ì¸¦ Á¦ ¥³±ºÀ¸·Î ÇÏ¿´À¸¸ç, ·¹ÀÌÀúÀÇ Á¶»ç¹æ¹ý¿¡ µû¸¥ µ¿Åë¾ïÁ¦È¿°ú¸¦ ºñ±³Çϱâ À§
ÇØ 30¸íÀ» ´ë»óÀ¸·Î 1.5W 15HzÀÇ ·¹ÀÌÀú Ãâ·ÂÀ¸·Î 3ºÐ°£ »ó¾Ç ¿ìÃø °ßÄ¡¿¡ ºñÁ¢Ã˹æ½Ä°ú
ÇÏ¾Ç ¿ìÃø °ßÄ¡¿¡´Â Á¢Ã˹æ½ÄÀ¸·Î °¢°¢ ·¹ÀÌÀú¸¦ Á¶»çÇÑ ÈÄ ·¹ÀÌÀúÀÇ Ãâ·Â, Á¶»ç½Ã°£°ú Àû
¿ë¹æ¹ý¿¡ µû¸¥ ·¹ÀÌÀú ¸¶ÃëÀ¯µµÀÇ È¿°ú¿Í ·¹ÀÌÀúÀÇ Àû¿ë¹æ½Ä¿¡ µû¸¥ È¿°ú¸¦ ºÐ¼®ÇÑ ¹Ù ´ÙÀ½
°ú °°Àº °á·ÐÀ» ¾ò¾ú´Ù.
1. ·¹ÀÌÀú¸¦ Á¶»çÇÑ °æ¿ì, Á¶»ç 5ºÐÈÄÀÇ Æò±ÕÄ¡¼öÀü±â°Ë»ç ¹ÝÀÀ¼öÄ¡´Â óġÀü¿¡ ºñÇØ ºñÁ¢
ÃË Àû¿ë½Ã¿¡´Â 32%, Á¢ÃË Àû¿ë½Ã¿¡´Â 35%·Î °¢°¢ Áõ°¡ÇÏ¿´À¸³ª(P<0.05), óġÀü°ú Á¶»çÈÄ
30ºÐ, 60ºÐÈÄ Ä¡¼öÀü±â°Ë»ç ¹ÝÀÀ¼öÄ¡ ºñ±³½Ã Åë°èÇÐÀû À¯ÀǼºÀº ¾ø¾ú´Ù.
2. ·¹ÀÌÀúÀÇ Ãâ·Â, Hz, Á¶»ç½Ã°£ µî Á¶»çÁ¶°Ç¿¡ µû¸¥ °¢ ±º°£ÀÇ Ä¡¼öÀü±â°Ë»ç ¹ÝÀÀ¿¡¼­ Åë
°èÇÐÀû À¯ÀǼºÀº ¾ø¾ú´Ù.
3. ºñÁ¢Ã˹æ½Ä°ú Á¢Ã˹æ½Ä µî Á¶»ç¹æ¹ý¿¡ µû¸¥ Ä¡¼öÀü±â°Ë»ç ¹ÝÀÀ¿¡¼­ Åë°èÇÐÀû À¯ÀǼºÀº
¾ø¾ú´Ù.
4. Pulsed Nd : YAG ·¹ÀÌÀú Àû¿ëÈÄ ½Ã°£ÀÇ °æ°ú¿¡ µû¸¥ Æò±Õ Ä¡¼öÀü±â°Ë»ç ¹ÝÀÀ¼öÄ¡´Â
30ºÐ À̳»¿¡ óġÀü ¼öÁØÀ¸·Î ȸº¹µÊÀ» º¸¿´´Ù.
ÀÌ»óÀÇ °á°ú·Î º¼ ¶§ Pulsed Nd : YAG ·¹ÀÌÀú Á¶»ç¸¦ ÇÏÁö ¾ÊÀº °ßÄ¡¿¡ ºñÇØ ·¹ÀÌÀúÁ¶
»ç 5ºÐÈÄ Æò±Õ Ä¡¼öÀü±â °Ë»ç ¹ÝÀÀ¼öÄ¡¸¦ ¾à 32-35% Á¤µµ Áõ°¡½ÃÄÑ Ä¡¼öÀÇ µ¿ÅëÁö°¢¿ªÄ¡¸¦
»ó½Â½ÃÅ´À» º¸¿©ÁÖ¾úÀ¸¸ç, ÀÌ·¯ÇÑ ·¹ÀÌÀúÀÇ ÀÌ¿ëÀº ÇâÈÄ Ä¡¼ö¸¶ÃëÀ¯µµ¸¦ À§ÇØ ´Üµ¶À¸·Î »ç
¿ëÇϱ⿡´Â ¾î·ÆÁö¸¸ ´Ù¸¥ µ¿ÅëÁ¶Àý ¹æ¹ý°ú º¹ÇյǾî ÀÓ»ó¿¡¼­ »ç¿ëµÉ ¼ö ÀÖÀ» °ÍÀ¸·Î »ç·á
µÈ´Ù.
#ÃÊ·Ï#
The purpose of this study was to evaluate the analgesic effect on pulp induced by
pulsed Nd : YAG laser according to the power density, irradiated time and the method
of application (Non-contact vs contact) in vivo.
Experiments were carried out on 90 volunteers who have sound 4 canines. Each
canine was grouped by the intensity and the time of irradiation of pulsed Nd : YAG
lase was measured. Mean EPT response(units) was measured at 5 min, 30 min, and 60
min after irradiation with various intensity(1.5-3W, 15-30Hz), irradiated time(1.5min,
3min), and application method (Non-contact and contact).
The results were as follows :
1. 5 minutes after irradiation, the mean EPT response (units) was increased by 32%
in the non-contact method and by 35% in the contact method of application. Which
showed significant difference in mean EPT response(units) compared to not-lased canine
in each groups (P<0.05).
2. The mean EPT response(units) with irradiating condition according to the various
laser intensity, and the irradiation time stastically did not show significant difference in
each grollps as time elapsed.
3. There was no significant difference between the non-contact and contact method in
the mean EPT response(units).
4. The mean EPT response(units) returned to the baseline value within 30 minutes.
In regard to the above results, the analgesic effect on pulp induced by pulsed Nd :
YAG laser resulted a slight increase of pulpal pain threshold, but it was not as high as
to replace the role of drug analgesia as whole. This technique can be used for inducing
pulpal analgesia as adjunct to other pain control methods and is needed to develop
better analgesic effects.