Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Er:YAG ·¹ÀÌÀú¸¦ ÀÌ¿ëÇÑ Ä¡¾Æ»èÁ¦ È¿°ú

EFFECTS OF ER:YAG LASER ABLATION ON THE DENTIN

´ëÇѼҾÆÄ¡°úÇÐȸÁö 2001³â 28±Ç 4È£ p.683 ~ 693
ÃÖ³²±â, ¾ç±ÔÈ£, ¹Ú»ó¿ø, ±è¿ÁÁØ,
¼Ò¼Ó »ó¼¼Á¤º¸
ÃÖ³²±â ( Choi Nam-Ki ) - Àü³²´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç&Ä¡ÀÇÇבּ¸¼Ò
¾ç±ÔÈ£ ( Yang Kyu-Ho ) - Àü³²´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç&Ä¡ÀÇÇבּ¸¼Ò
¹Ú»ó¿ø ( Park Sang-Won ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
±è¿ÁÁØ ( Kim Ok-Joon ) - Àü³²´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­º´¸®Çб³½Ç

Abstract

Er:YAG ·¹ÀÌÀú´Â ÆÄÀåÀÌ ¹°ÀÇ ÁÖÈí¼ö Á¤Á¡°ú ÀÏÄ¡ÇÏ´Â ÀÇ ¹æÃâÆÄÀåÀ» °¡Áö±â ¶§¹®¿¡, ¹°ºÐ»ç¸¦ Çϸ鼭 »ç¿ëÇßÀ» ¶§, ´Ù¸¥ ·¹ÀÌÀúº¸´Ù ¿­¼Õ»óÀº ´õ ÀÛÀ¸¸é¼­ Ä¡¾Æ°æÁ¶Á÷À» º¸´Ù È¿°úÀûÀ¸·Î »èÁ¦ÇÑ´Ù°í ¾Ë·ÁÁ® ÀÖ´Ù. Er:YAG ·¹ÀÌÀúÀÇ »ó¾ÆÁú »èÁ¦ È¿°ú¸¦ Æò°¡ÇÏ°íÀÚ ¹ß°ÅµÈ ¼Ò±¸Ä¡¿Í ´ë±¸Ä¡¸¦ ´ë»óÀ¸·Î »ó¾ÆÁú ½ÃÆíÀ» Á¦ÀÛÇÏ°í ÀÇ pulsed Er:YAG ·¹ÀÌÀú(SDL-300EN, »ï¼ºÀüÀÚ, Çѱ¹)¸¦ handpieceÇüÀÇ Àü´Þ°è¸¦ ÀÌ¿ëÇÑ ºñÁ¢ÃË½Ä ¹æ¹ýÀ¸·Î, ¹°¿¡ ´ã±ÅÁø ½Ã°£°ú ·¹ÀÌÀú Á¶»ç½Ã°£¿¡ µû¸¥ »èÁ¦·®°ú ÇüŸ¦ Á¶»ç, ºÐ¼®ÇÏ¿© ´ÙÀ½°ú °°Àº °á°ú¸¦ ¾ò¾ú´Ù. 1. °ÇÀü »ó¾ÆÁú¿¡ ´ëÇÑ Á¶»ç °á°ú¹°¿¡ ´ã±º ½Ã°£ÀÌ Áõ°¡ÇÒ¼ö·Ï »èÁ¦À²ÀÌ Áõ°¡ÇÏ¿´´Ù. 2. °ÇÀü »ó¾ÆÁú°ú ¿ì½Ä »ó¾ÆÁú¿¡ 150mJ, 10HzÀÇ Á¶°ÇÀ¸·Î, 30ÃÊ°£ ·¹ÀÌÀú¸¦ Á¶»çÇßÀ» ¶§, ¿ì½Ä»ó¾ÆÁú¿¡ ºñÇØ °ÇÀü »ó¾ÆÁú¿¡¼­ surface irregularity°¡ Áõ°¡ÇÏ°í »ó¾Æ¼¼°üÀÌ ¿­¸®´Â °æÇâÀÌ ÀÖ¾úÀ¸¸ç crackÀÌ °üÂûµÇ¾ú´Ù. ¶ÇÇÑ ¿ì½Ä »ó¾ÆÁú¿¡ ºñÇØ ¸¹Àº źÁ¶°¢(ash flecks), crackÀÌ °üÂûµÇ¾ú°í »ó¾Æ¼¼°üÀÇ ºÒ¿¬¼Ó¼º (inconsistency)ÀÌ °üÂûµÇ¾ú´Ù. 3. ¿ì½Ä »ó¾ÆÁú¿¡¼­ 30ÃÊ·Î Á¶»çÇÑ °æ¿ì¿¡¼­´Â dark zoneÀÌ ¿Íµ¿¿¡ ±¹ÇÑµÇ¾î ³ªÅ¸³µÀ¸¸ç ÀÛÀº fleckµéÀÌ °üÂûµÇ¾ú°í, 1ºÐ°£ Á¶»çÇÑ °æ¿ì¿¡¼­´Â 30ÃÊÀÇ °æ¿ìº¸´Ùµµ ¿Íµ¿ÀÌ ´õ ³Ð¾úÀ¸¸ç, crackÀÌ »ó¾Æ¼¼°ü ÁÖÇà¹æÇâ°ú Á÷°¢À¸·Î Çü¼ºµÈ °ÍÀ» °üÂû ÇÒ ¼ö ÀÖ¾ú´Ù. 2ºÐ°£ Á¶»çÇÑ °æ¿ì´Â ¿Íµ¿ÀÌ °¡Àå ³Ð¾úÀ¸¸ç crackÀÌ ´õ ¸¹ÀÌ Çü¼ºµÈ °ÍÀ» º¼ ¼ö ÀÖ¾ú´Ù.

The purpose of this study was to evaluate the effects of Er:YAG laser on cutting efficacy and its histologic findings. Dentin specimens of human premolars and molars were used and irradiated by Er:YAG laser with noncontact handpiece type delivery system under different treatment condition of irradiation time. Cavity pattern and volume were evaluated to determine the cutting efficacy and following results were obtained. 1. Cutting volume of sound dentin was getting larger with time immersed in water increase 2. With the condition of irradiation (150mJ, 10Hz, 30sec), surface irregularity was more increased in sound dentin comparing to carious dentin. For the light microscopic examination, dentinal tubules were opened and ash flecks and cracks were noted with inconsistence of dentinal tubules. 3. In case of 30 sec. irradiation in carious dentin, dark zone was limited to small focus whereas 1 min. irradiation, more wider, and cracks were noted in the perpendicular to direction of dentinal tubules. For the 2 min. irradiation, cavity was the widest and more cracks were found.

Å°¿öµå

Er:YAG ·¹ÀÌÀú;»ó¾ÆÁú;»èÁ¦·®;Á¶Á÷ÇÐÀû ¼Ò°ß
Laser;Er:YAG;Dentin;Cutting volume;Histologic finding

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI