Abstract

º» Àӻ󿬱¸´Â »ó¾ÆÁúÁö°¢°ú¹ÎÁõÀ» Ä¡·áÇϱâ À§ÇÑ ¿©·¯ °¡Áö ¹æ¹ý Áß È¿°úÀûÀÎ ¹æ¹ýÀÇ Çϳª·Î ¾Ë·ÁÁ® ÀÖ´Â ºÒ¼Ò(NaF)¸¦ ÀÌ¿ëÇÏ¿© ºÒ¼ÒÅ×ÀÌÇÁ(SCMC-T-5)¸¦ °³¹ß, Á¦Á¶ÇÏ°í, À̸¦ ÀÌ¿ëÇÏ¿© »ó¾ÆÁú Áö°¢°ú¹Î Ä¡·á È¿°ú¸¦ ±âÁ¸ÀÇ ºÒ¼Ò¹Ù´Ï½¬ (Cavity ShieldTM)¿Í ºñ±³, Æò°¡ÇÏ¿´´Ù. »ó¾ÆÁú Áö°¢°ú¹ÎÁõÀÌ ÀÖ´Â °Ç°­ÇÑ 20´ë ³²³à 22¸í(88°³ Ä¡¾Æ)ÀÌ º» Àӻ󿬱¸¿¡ Âü°¡ÇÏ¿´À¸¸ç, °¢°¢ 11¸í¾¿ ºÒ¼ÒÅ×ÀÌÇÁ¸¦ ºÎÂø½ÃŲ ½ÇÇ豺°ú ºÒ¼Ò¹Ù´Ï½¬¸¦ µµÆ÷ÇÑ ´ëÁ¶±ºÀ¸·Î ºÐ·ùÇÏ¿´´Ù. ºÒ¼Ò Á¦Á¦´Â Á¦Á¶»çÀÇ Áö½Ã¿¡ µû¶ó Àû¿ëµÇ¾úÀ¸¸ç, ºÒ¼Ò Á¦ Á¦ µµÆ÷ Àü, µµÆ÷ 3ÀÏÈÄ, 1ÁÖÀÏ ÈÄ, 4ÁÖÀÏ ÈÄ ´ë»óÄ¡¾Æ¿¡ ¾ÐÃà°ø±â¿Í ¾óÀ½¸·´ë¸¦ ÀÌ¿ëÇÏ¿© ÀÚ±ØÀ» °¡ÇÑ µÚ visual analog scale(VAS)À» ÀÌ¿ëÇÏ¿© ÅëÁõ Á¤µµ¸¦ Ç¥½ÃÇϵµ·Ï ÇÏ¿´´Ù. ½ÇÇ豺¿¡¼­ VAS scores´Â Ãʱ⿡ 38.636(air), 62.273(ice), 3ÀÏ ÈÄ 30.273(air), 49.545(ice), 1ÁÖÀÏ ÈÄ 28.182(air), 40.000(ice), 4ÁÖÀÏ ÈÄ 26.364(air), 37.727(ice)À̾úÀ¸¸ç, Ãʱâ VAS socres¿¡ ºñÇØ ¸ðµç VAS scores´Â Åë°èÇÐÀûÀ¸·Î À¯ ÀǼº ÀÖ°Ô °¨¼ÒµÇ¾ú´Ù. ´ëÁ¶±º¿¡¼­ VAS scores´Â Ãʱ⿡ 42.274(air), 65.909(ice), 3ÀÏ ÈÄ 34.091(air), 55.909(ice), 1ÁÖÀÏ ÈÄ 28.636(air), 40.909(ice), 4ÁÖÀÏ ÈÄ 27.727(air), 31.364(ice)À̾úÀ¸¸ç, 3ÀÏ ÈÄ¿¡ ½ÃÇàµÈ ¾ÐÃà°ø±â¿¡ ÀÇÇÑ Àڱذ˻縦 Á¦¿ÜÇÑ ¸ðµç VAS scores´Â Ãʱâ VAS socres¿Í ºñ±³ÇßÀ» ¶§ Åë°èÇÐÀûÀ¸·Î À¯ÀǼº ÀÖ°Ô °¨¼ÒµÇ¾ú´Ù. º» Àӻ󿬱¸¿¡ »ç¿ëµÈ ºÒ¼ÒÅ×ÀÌÇÁ¿Í ºÒ¼Ò¹Ù´Ï½¬´Â »ó¾ÆÁú Áö°¢°ú¹ÎÁõÀ» È¿°úÀûÀ¸·Î °¨¼Ò½ÃÄ×°í, µÎ ¾àÁ¦°£ÀÇ Ä¡·áÈ¿°úÀÇ Â÷ÀÌ´Â ¾ø¾ú´Ù.

In this clinical research, the fluoride tape(SCMC-T-5) using fluoride(NaF) was developed and manufactured and the treatment effect of the fluoride tape in dentin hypersensitivity patients was evaluated and compared with the effect of existing fluoride varnish(CavityShieldTM). Twenty two healthy adult patients(88 teeth) having dentin hypersensitivity participated in this clinical research and they were divided into two groups. The fluoride product was applied according to the manufacturer¡¯s instruction and the level of pain in the tooth after giving irritation using compressed air and ice stick was measured just after the application, after 3 days, after a week and after 4 weeks each using visual analog scale(VAS). In the experimental group, compared with the early VAS scores, all other VAS scores showed the significant decreases statistically. In the control group, all VAS scores except the VAS score of 34.091(air) measured 3 days after(using the irritation examination by the compressed air) showed the significant decreases statistically when compared with the early VAS scores. The fluoride tape and fluoride varnish used in this clinical research were able to treat the dentin hypersensitivity effectively.

Å°¿öµå

»ó¾ÆÁú Áö°¢°ú¹ÎÁõ;ºÒ¼ÒÅ×ÀÌÇÁ;ºÒ¼Ò¹Ù´Ï½¬
dentin hypersensitivity;fluoride tape;fluoride varnish