Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Cone-beam computed tomography¸¦ ÀÌ¿ëÇÑ ¹Ì¸ÍÃâ ¿µ±¸Ä¡ÀÇ °èÃø

ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH

´ëÇѼҾÆÄ¡°úÇÐȸÁö 2012³â 39±Ç 2È£ p.139 ~ 144
±è¼ºÈñ, ±è¿µÁ¾, ±è½Å, Á¤¼ºÈñ,
¼Ò¼Ó »ó¼¼Á¤º¸
±è¼ºÈñ ( Kim Seong-Hee ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ¼Ò¾ÆÄ¡°úÇб³½Ç
±è¿µÁ¾ ( Kim Young-Jong ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ¼Ò¾ÆÄ¡°úÇб³½Ç
±è½Å ( Kim Shin ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ¼Ò¾ÆÄ¡°úÇб³½Ç
Á¤¼ºÈñ ( Jeong Sung-Hee ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ¼Ò¾ÆÄ¡°úÇб³½Ç

Abstract

º» ¿¬±¸´Â CBCT(Cone-beam computed tomography)¿µ»ó¿¡¼­ ¹Ì¸ÍÃâ Ä¡¾Æ Å©±â ÃøÁ¤ÀÇ ÀçÇö¼º°ú Á¤È®¼ºÀ» Æò°¡Çϱâ À§ÇØ ½ÃÇàµÇ¾ú´Ù. ¸Åº¹Ä¡¸¦ ÁÖ¼Ò·Î ºÎ»ê´ëÇб³ Ä¡°úº´¿ø ¼Ò¾ÆÄ¡°ú¿¡ ³»¿øÇÑ È¥ÇÕÄ¡¿­±â ȯÀÚ Áß Áø´Ü ¸ñÀûÀ¸·Î CBCT äµæ¿¡ µ¿ÀÇÇÑ È¯ÀÚÀÇ ¹Ì¸ÍÃâ °ßÄ¡ ¹× ¼Ò±¸Ä¡ 69°³¸¦ ´ë»óÀ¸·Î ÇÏ¿´´Ù. CBCT ¿µ»ó¿¡¼­ ÃøÁ¤ÇÑ ¹Ì¸ÍÃâ Ä¡¾ÆÀÇ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡¿Í µ¿ÀÏÇÑ Ä¡¾Æ°¡ ±¸°­ ³»·Î ¿ÏÀüÈ÷ ¸ÍÃâÇÑ ÈÄ Ã¤µæÇÑ ¼®°í ¸ðÇü¿¡¼­ ´ë»ó Ä¡¾Æ¸¦ digital caliper·Î ÃøÁ¤ÇÑ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡¸¦ ºñ±³ÇÏ¿© ´ÙÀ½°ú °°Àº °á·ÐÀ» ¾ò¾ú´Ù. 1. CBCT ¿µ»ó¿¡¼­ ¹Ì¸ÍÃâ Ä¡¾Æ¸¦ °èÃøÇÏ´Â ¹æ¹ýÀº ÀçÇö¼ºÀÌ ³ô´Ù(ICC=0.91). 2. CBCT ¿µ»ó¿¡¼­ ÃøÁ¤ÇÑ ¹Ì¸ÍÃâ Ä¡¾ÆÀÇ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡¿Í ¼®°í ¸ðÇü¿¡¼­ ÃøÁ¤ÇÑ ´ë»ó Ä¡¾ÆÀÇ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡´Â ³ôÀº »ó°ü °ü°è°¡ ÀÖ¾ú´Ù(r=0.91). 3. CBCT ¿µ»ó¿¡¼­ ÃøÁ¤ÇÑ ¹Ì¸ÍÃâ Ä¡¾Æ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡¿Í ¼®°í ¸ðÇü¿¡¼­ ÃøÁ¤ÇÑ ´ë»ó Ä¡¾ÆÀÇ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡´Â Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ÀÖ¾ú´Ù( <0.05). CBCT ¿µ»ó¿¡¼­ ÃøÁ¤ÇÑ ¹Ì¸ÍÃâ Ä¡¾Æ ÃÖ´ë ±Ù¿ø½É Æø°æÀÇ °èÃøÄ¡°¡ ¼®°í ¸ðÇü¿¡¼­ ÃøÁ¤ÇÑ ´ë»ó Ä¡¾ÆÀÇ ÃÖ´ë ±Ù¿ø½É Æø°æ °èÃøÄ¡º¸´Ù Æò±Õ 0.2 mm ÀÛ°Ô ÃøÁ¤µÇ¾ú´Ù. ±×·¯³ª ÀÌ·¯ÇÑ Â÷ÀÌ´Â ÀÓ»óÀûÀ¸·Î ¼ö¿ë °¡´ÉÇÑ ¼öÁØÀ̶ó »ý°¢µÈ´Ù.

The purpose of this study was to evaluate the accuracy and reproducibility of measuring the size of unerupted permanent tooth via cone beam computed tomography(CBCT). Ten children were scanned with dental CBCT, and 3-dimensional reconstruction of the dentitions were generated CBCT. Mesio-distal dimension and buccolingual dimension of the teeth were made directly on the model with a high-precision digitalcaliper and on the CBCT by using three-dimensional dental imaging software. Reliability and accuracy were assessed by using intraclass correlation and paired -tests. ( <0.05) The results were as follows : 1. Intraclass correlations were above 0.9 for Both the CBCT and the model measurements, showinghigh reliability. 2. Although there were high correlation values(r=0.91) between CBCT and model messurement methods, comparisons between the CBCT and model messurement methods showed a statistically significant difference( <0.05). 3. The CBCT measurements tended to slightly underestimate by 0.2 mm. But, the systematic difference of CBCT measurements were clinically acceptable Therefore, CBCT measurement method can be used to measure the size of unerupted teeth in a sufficiently accurate way.

Å°¿öµå

¹Ì¸ÍÃâ Ä¡¾Æ; Ä¡¾Æ Å©±â
CBCT(Cone-beam computed tomography); Unerupted teeth; Tooth size

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI