Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

´Ù¾çÇÑ ¿ë¾×¿¡ µû¸¥ Bulk-fill º¹ÇÕ·¹ÁøÀÇ »öÁ¶¾ÈÁ¤¼º Æò°¡

Color Stability of Bulk-Fill Resin Composites after Immersion in Different Media

´ëÇѼҾÆÄ¡°úÇÐȸÁö 2019³â 46±Ç 4È£ p.353 ~ 361
°­¼º±Õ, ¼ÛÁöÇö,
¼Ò¼Ó »ó¼¼Á¤º¸
°­¼º±Õ ( Kang Sung-Kyoon ) - ¿ø±¤´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç
¼ÛÁöÇö ( Song Ji-Hyun ) - ¿ø±¤´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç

Abstract

ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº bulk-fill º¹ÇÕ·¹Áø°ú ÀüÅëÀûÀÎ º¹ÇÕ·¹ÁøÀ» ´ë»óÀ¸·Î ´Ù¾çÇÑ ¿ë¾×°ú ½ÃÆíÀÇ µÎ²²¿¡ µû¸¥ »öÁ¶¾ÈÁ¤¼ºÀÇ Â÷À̸¦ Æò°¡ÇÏ´Â °ÍÀÌ´Ù. ÀüÅëÀûÀÎ º¹ÇÕ·¹ÁøÀ¸·Î Filtek¢â Z250, Filtek¢â Z350XT¿Í, bulk-fill º¹ÇÕ·¹ÁøÀ¸·Î Filtek¢â Bulk-fill Posterior Restorative, Tetric¢ç N-Ceram Bulk FillÀÌ »ç¿ëµÇ¾ú´Ù. °¢ º¹ÇÕ·¹Áø ½ÃÆíÀº 3°³ÀÇ ±ºÀ¸·Î ³ª´©¾î °¢°¢ Áõ·ù¼ö, ·¹µå¿ÍÀÎ, Ä¿ÇÇ ¿ë¾×¿¡ ħÀü½ÃŲ µÚ, ħÀü 1, 7, 28ÀÏ¿¡ »öÁ¶ ÃøÁ¤À» ½ÃÇàÇÏ¿© °¢ ½ÃÁ¡°ú Ãʱ⠱âÁØÁ¡ÀÇ CIE L*a*b*°ªÀÇ »öÂ÷(¥ÄE*)°¡ °è»êµÇ¾ú´Ù. ¸ðµç º¹ÇÕ·¹ÁøÀº ·¹µå¿ÍÀο¡¼­ °¡Àå Å« »öÁ¶º¯È­°¡ ³ªÅ¸³µÀ¸¸ç, ±× ´ÙÀ½Àº Ä¿ÇÇ, Áõ·ù¼ö ¼ø¼­¿´´Ù. Filtek¢â Z350XT´Â ¸ðµç ¿ë¾×¿¡¼­°¡Àå Å« »öÁ¶º¯È­¸¦ ³ªÅ¸³Â°í, ´ÙÀ½Àº Filtek¢â Bulk-fill Posterior Restorative¿´´Ù. ±× µÚ·Î´Â Filtek¢â Z250°ú Tetric¢ç N-Ceram Bulk FillÀÌÀ¯»çÇÑ ¼öÁØÀÇ »öÁ¶º¯È­¸¦ ³ªÅ¸³Â´Ù. Bulk-fill º¹ÇÕ·¹Áø¿¡¼­ 2 mm¿Í 4 mmÀÎ ½ÃÆíÀÇ µÎ²²¿¡ µû¸¥ »öÁ¶º¯È­ÀÇ Â÷ÀÌ´Â ³ªÅ¸³ªÁö ¾Ê¾Ò´Ù.

The aim of this study was to evaluate the color stability of bulk-fill and conventional resin composites with respect to different storage media and thickness of composites. Filtek¢â Z250 and Filtek¢â Z350XT were evaluated as conventional resin composites. Filtek¢â Bulk-fill Posterior Restorative and Tetric¢ç N-Ceram Bulk Fill were evaluated as bulk-fill resin composites. CIE L*a*b* values of baseline were measured after 24 hours of storage in distilled water, and each resin composite group was divided into three subgroups and stored in distilled water, red wine, and coffee media respectively. Again after 1, 7 and 28 days of immersion, color changes (¥ÄE*) were calculated using the CIE L*a*b* values. The greatest ¥ÄE* was observed in red wine for all resin composites, and the mean color changes were ranked in the increasing order of distilled water, coffee, red wine. Filtek¢â Z350XT exhibited the greatest color change in all media, followed by Filtek¢â Bulk-fill Posterior Restorative. Filtek¢â Z250 and Tetric¢ç N-Ceram Bulk Fill followed with similar mean color change values. According to the 2 different thicknesses of 2 mm and 4 mm of bulk-fill resin composites, there was no thickness-related difference on color changes.

Å°¿öµå

Color stability; Bulk-fill resin composites; Restorative materials

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

   

µîÀçÀú³Î Á¤º¸

KCI