Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Hydroxyapatite¸¦ À̽ÄÇÑ ÀÓÇöõÆ® ÁÖÀ§ °ñ°á¼ÕºÎ¿¡¼­ rhPDGF-BB¿Í rhBMP-2°¡ °ñ³» ÀÓÇöõÆ® osseointegration¿¡ ¹ÌÄ¡´Â ¿µÇâ: Micro-CT ºÐ¼®°ú Á¶Á÷ÇÐÀû Æò°¡

Effect of rhPDGF-BB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite: Micro-CT and histologic analysis

¹ÚÁöÇö, ±è¸íÁø, Ȳ¼øÁ¤,
¼Ò¼Ó »ó¼¼Á¤º¸
¹ÚÁöÇö ( Park Jee-Hyun ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
±è¸íÁø ( Kim Myung-Jin ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
Ȳ¼øÁ¤ ( Hwang Sun-Jung ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç

Abstract


Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are wellknown representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT.

Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three 8x8x6mm-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors;Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implanct contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology.

Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: pa¢¶¡¯0.011, BMP group: pa¢¶¡¯0.006 /BMD; PDGF group:pa¢¶¡¯0.020, BMP group: pa¢¶¡¯0.011) and BIC measures of BMP group were significantly higher than PDGF group(pa¢¶¡¯0.015). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group(pa¢¶¡¯0.048). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections.

Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

Å°¿öµå

Implant;HA;rhPDGF-BB;rhBMP-2;Micro-CT;Histology

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed