Abstract


Purpose: The objective of the present study was to determine the capability of electrospun silk fibroin as a biomaterial template for bone formation when mixed with nano-hydoxyapatite in vivo.

Materials and Methods: Ten New Zealand white rabbits were used for this study and bilateral round shaped defects were formed in the parietal bone (diameter: 8.0 mm). The electrospun silk fibroin was coated by nano-hydroxyapatite and grafted into the right parietal bone (experimental group). The left side (control group) did not receive a graft. The animals were sacrificed at 6 weeks and 12 weeks, humanly. The microcomputerized tomogram (¥ìCT) was taken for each specimen. Subsequently, they were undergone decalcification and stained for the histological analysis.

Results: The average value of all measured variables was higher in the experimental group than in the control at 6 weeks after the operation. BMC in the experimental group at 6 weeks after operation was 48.94 ¡¾ 19.25 and that in the control was 26.17 ¡¾ 16.40 (P = 0.027). BMD in the experimental group at 6 weeks after operation was 324.59 ¡¾ 165.24 and that in the control was 173.03 ¡¾ 120.30 (P = 0.044). TMC in the experimental group at 6 weeks after operation was 19.50 ¡¾ 6.00 and that in the control was 10.52 ¡¾ 6.20 (P = 0.011). TMD in the experimental group at 6 weeks after operation was 508.88 ¡¾ 297.57 and that in the control was 273.54 ¡¾ 175.91 (P = 0.06). Gross image of both groups showed higher calcification area at 12 weeks than them in 6 weeks. The average value of ¥ìCT analysis was higher at 12 weeks than that in 6 weeks in both groups. BMC in the experimental group at 12 weeks after operation was 51.21 ¡¾ 8.81 and that in the control was 33.47 ¡¾ 11.13 (P = 0.010). BMD in the experimental group at 12 weeks after operation was 323.39 ¡¾ 21.54 and that in the control was 197.75 ¡¾ 76.23 (P = 0.012). TMC in the experimental group at 12 weeks after operation was 21.44 ¡¾ 5.30 and that in the control was 13.31 ¡¾ 4.17 (P = 0.008). TMD in the experimental group at 12 weeks after operation was 524.47 ¡¾ 19.37 and that in the control was 299.60 ¡¾ 136.20 (P = 0.016).

Conclusion: The rabbit calvarial defect could be successfully repaired by electrospun silk nano-fiber combined with nano-hydroxyapatite.

Å°¿öµå

Silk fibroin; Hydroxyapatite; Calvaria