Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ç÷°ü ºñƲ¸²ÀÌ ¹é¼­ õÃþÇϺ¹ºÎ µ¿¸ÆÀÇ Ãʹ̼¼¹®ÇÕ¿¡ ¹ÌÄ¡´Â È¿°ú

Twisting Effect on Supermicroanastomosis of the Superficial Inferior Epigastric Artery in a Rat Model

¼­¹ÌÇö, ±è¼º¹Î, °­Áö¿µ, ¸íÈÆ, ÀÌÁ¾È£,
¼Ò¼Ó »ó¼¼Á¤º¸
¼­¹ÌÇö ( Seo Mi-Hyun ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
±è¼º¹Î ( Kim Soung-Min ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
°­Áö¿µ ( Kang Ji-Young ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
¸íÈÆ ( Myoung Hoon ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç
ÀÌÁ¾È£ ( Lee Jong-Ho ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ ±¸°­¾Ç¾È¸é¿Ü°úÇб³½Ç

Abstract


Purpose: The advent of microsurgical technique and instruments, particularly in the field of perforator flap and supermicrosurgery, which have expanded the scope of microsurgery. However, supermicroanastomosis without any compression, tension, or distortions must be achieved to reach successful outcomes. Small-caliber vessels, such as those with an internal diameter less than 0.2 mm, are susceptible to inadvertent twisting of the anastomosis. In this study, using the superficial inferior epigastric artery (SIEA)-based flap model in Sprague-Dawley (SD) rats, we evaluated the acceptable limits of twisting effects on supermicroanastomotic sites.

Methods: A total of 20 supermicroanastomoses were performed using the SIEA-based flap model in 10 male SD rats, 10-weeks-of-age, weighing 300~350 g. Rats were divided into five groups of two with four flaps as follows: 1) sham, 2) control group with end to end SIEA arterial supermicroanastomosis, 3) experimental I (EA1) with 90degrees twisting, 4) experimental II (EA2) with 180degrees twisting, and 5) experimental III (EA3) with 270degrees twisting of the supermicroanastomosis. Each SIEA was anastomosed using six 11-0 Ethilon(R) (Ethicon Inc. Co., NJ, USA) stitches except in the sham group where the SIEA was only clamped with Supermicro vascular clamps(R) (S&T, Neuhausen, Switzerland) for 20 minutes.

Results: The anastomosed arterial patency showed no remarkable changes according to doppler waveforms measured with a Smardop 45 Doppler System (Hadeco Inc., Kawasaki, Japan). The pulsatility index (PI) was increased at postoperative day 10 in the EA2 and EA3 groups, and the resistance index (RI) showed no statistically significant difference between preoperative and postoperative values at 10 days. Histologic specimens from the EA3 group showed increased tunica media necrosis, convolution of the internal elastic lamina, densely packed platelets, fibrin, and erythrocytes. Flap viability and anastomosed vessel patency were not significantly affected by the degree of arterial twisting in this study, other than in the EA3 group where minor effects on arterial patency of the microanastomoses were encountered.

Conclusion: It appears that minor twisting on small caliber arteries, used in supermicroanastomoses, can be tolerated. However, twisting should be avoided as much as possible, and more than 180degrees twisting must be prevented in clinical practice.

Å°¿öµå

End to end anastomosis; Oral and maxillofacial reconstruction; Superficial inferior epigastric artery based flap; Supermicrosurgery; Twisting effect

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed