Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Acidic primer¸¦ ÀÌ¿ëÇÑ ±³Á¤¿ë ºê¶óÄÏ Á¢ÂøÀÇ Àü´Ü°áÇÕ°­µµ

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM

Korean Journal of Orthodontics 2001³â 31±Ç 1È£ p.137 ~ 147
¿ì¿µ±Õ, ±Ç¼ø¿ë, ÁøÈÆÈñ,
¼Ò¼Ó »ó¼¼Á¤º¸
¿ì¿µ±Õ (  ) - °¡Å縯´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç
±Ç¼ø¿ë (  ) - °¡Å縯´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç
ÁøÈÆÈñ (  ) - ¿¹Ä¡°úÀÇ¿ø

Abstract


Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups

Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer,
Group V using Transbond XT adhesive system to the enamel treated with 37% phosphoric acid.

The sh,3~ar bond strength was measured with Instron universal testing machine after storing in 37¡ÆC water bath for 48 horrs. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI).

The results were as follows

1. There were no significant differences in shear bond strength between group III (8.69 ¡¾ 2.72 Wa), group IV (9.7 ¡¾ 3.16 Wa), and group V (10.48 ¡¾ 2.60 Mpa) (p>0.05).
2. The shear bond strength of group III and group IV was significantly higher than that of group I (1.09 ¡¾ 0.53 Mpa), and Group II (2.70 ¡¾ 1.46Mpa) (p<0.05).
3. The ARI of group IV (2.1 ¡¾ 1.1) and group V (2.9 ¡¾ 0.3) was significantly higher than that of group I (0.2 ¡¾ 0.4), group II (0.3 ¡¾ 0.9) and group III (0.2 ¡¾ 0.4) (p<0.05).
4. There were no significant difference between the ARI of group IV and group V (p>0.05).
This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

Å°¿öµå

Àü´Ü °áÇÕ °­µµ;Á¢ÂøÁ¦ ÀÜ·ùÁö¼ö;acidlc primer;shear bond strength;ARI;acidic primer

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

SCI(E)
KCI
KoreaMed