Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

±¤ÁßÇÕ±âÀÇ ±¤¿ø¿¡ µû¸¥ ºê¶óÄÏ Àü´Ü°áÇÕ°­µµ ºñ±³

Comparison of the shear bond strength of brackets in regards to the light curing source

Korean Journal of Orthodontics 2006³â 36±Ç 3È£ p.198 ~ 206
Â÷Á¤¿­, À̱âÁØ, ¹Ú¼±Çü, ±èÅ¿ø, À¯Çü¼®,
¼Ò¼Ó »ó¼¼Á¤º¸
Â÷Á¤¿­ ( Cha Jung-Yul ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç
À̱âÁØ ( Lee Kee-Joon ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç
¹Ú¼±Çü ( Park Sun-Hyung ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç
±èÅ¿ø ( Kim Tae-Weon ) - ±è¿¬Áß¼ÛÀ±ÇåÄ¡°úÀÇ¿ø
À¯Çü¼® ( Yu Hyung-Seog ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç

Abstract

Á¦³í ÇöóÁ ¾ÆÅ© ±¤ÁßÇձ⳪ LED ±¤ÁßÇձⰡ Ä¡°ú¿µ¿ª¿¡ ¼Ò°³µÈ ÀÌÈÄ·Î ±âÁ¸ÀÇ ÅÖ½ºÅÙ ÇÒ·Î°Õ ±¤ÁßÇձ⸦ »ç¿ëÇÒ ¶§¿¡ ºñÇØ ±³Á¤ÀåÄ¡ÀÇ ºÎÂø½Ã°£ÀÌ ÇöÀúÇÏ°Ô ÁÙ¾îµé ¼ö ÀÖ°Ô µÇ¾ú´Ù. Á¦³í ÇöóÁ ¾ÆÅ© ±¤ÁßÇձ⿡ ´ëÇÑ ÁßÇսð£°ú Àü´Ü°­µµ¿¡ ´ëÇؼ­´Â ¿©·¯ ¿¬±¸°¡ ÀÖ¾î¿Ô´ø ¹Ý¸é, LED ±¤ÁßÇձ⸦ ÀÌ¿ëÇÏ¿© ±³Á¤¿ëÀåÄ¡ÀÇ ºÎÂøÀ» À§ÇÑ ÁßÇս𣿡 ´ëÇÑ ¿¬±¸´Â ¹ÌÁøÇÏ´Ù. º» ¿¬±¸ÀÇ ¸ñÀûÀº LED ±¤ÁßÇÕ±âÀÇ ÁßÇս𣿡 µû¸¥ °áÇÕ°­µµ¸¦ ÇöóÁ ¾ÆÅ© ±¤ÁßÇÕ±â¿Í ºñ±³ÇÏ¿© ÀûÀýÇÑ ºê¶óÄÏÀÇ ºÎÂø°­µµ¸¦ ¾ò±â À§ÇØ ¿ä±¸µÇ´Â ÁßÇսð£À» ¾Ë¾Æº¸´Âµ¥ ÀÖ´Ù. 120°³ÀÇ ¹ßÄ¡µÈ »ç¶÷ÀÇ ¼Ò±¸Ä¡¿¡ ÄÄÆ÷Áþ ·¹ÁøÀ¸·Î ºê¶óÄÏÀ» ºÎÂø½ÃŲ ÈÄ 4ÃÊ, 6ÃÊ, 8ÃÊ µ¿¾È ÇöóÁ ¾ÆÅ© ±¤¿ø°ú LED ±¤¿øÀ¸·Î °¢°¢ ÁßÇÕ½ÃÄ×´Ù. ±× ÈÄ °áÇÕ°­µµ¸¦ ¸¸´É½ÃÇè±â(Universal Testing Machine)·Î °èÃøÇÑ °á°ú, ÇöóÁ ¾ÆÅ© ±¤ÁßÇձ⿡¼­´Â 4ÃÊ À̻󿡼­, LED ±¤ÁßÇձ⿡¼­´Â 8ÃÊ ÀÌ»óÀÇ ÁßÇս𣿡¼­ ±âÁ¸ÀÇ ÇÒ·Î°Õ ±¤¿øÀ» 40ÃÊ°£ ³ëÃâ½ÃÄ×À» ¶§¿Í ºñ½ÁÇÑ Àü´Ü°áÇÕ°­µµ¸¦ ³ªÅ¸³»¾ú´Ù. ÇöóÁ ¾ÆÅ© ±¤ÁßÇÕ±â¿Í LED ±¤ÁßÇÕ±âÀÇ ÁßÇսð£ÀÌ Á¢ÂøÁ¦ ÀÜ·ùÁö¼ö (adhesive remnant index) ¼öÄ¡¿¡ ´ëÇØ ¿µÇâÀ» ¹ÌÄ¡Áö ¾Ê¾Ò´Ù.

With the introduction of the xenon plasma arc curing light and the LED curing light as orthodontic curing lights, the polymerizing time of orthodontic composites has clearly decreased. In contrast to various research cases regarding the polymerization time and bond strength of the xenon plasma arc curing light, not enough research exists on the LED curing light, including the appropriate polymerization time. The objective of this research was to compare the bond strength of the plasma curing light and the LED curing light in regards to the polymerization time. The polymerization time needed to achieve an appropriate adhesion strength of the bracket has also been studied. After applying orthodontic brackets using composite resin onto 120 human premolars, the plasma arc curing light and the LED curing light were used for polymerization for 4, 6, and 8 seconds accordingly. This research proved that the LED curing light provided appropriate bond strength for mounting orthodontic brackets even with short seconds of polymerization. The expensive cost and large size of the device limits the use of the plasma arc curing light, whereas the low cost and easy handling of the LED curing light may lead to greater use in orthodontics.

Å°¿öµå

LED ±¤ÁßÇÕ±â;ÇöóÁ ¾ÆÅ© ±¤ÁßÇÕ±â;Àü´Ü°áÇÕ°­µµ
LED curing light;Plasma arc curing light;Shear bond strength

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

SCI(E)
KCI