±³Á¤Ä¡·á¿¡¼­ °íÁ¤¿øÀÇ Á¶ÀýÀº ±³Á¤ ÀåÄ¡ÀÇ ¼±Åðú Àû¿ë¿¡¼­ °¡Àå Áß¿äÇÑ ¿ä¼Ò Áß ÇϳªÀÌ´Ù. ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº ±³Á¤¿ë ¹Ì´Ï½ºÅ©·ùÀÇ ½Ä¸³ Áï½Ã ±³Á¤·ÂÀ» Àû¿ëÇÑ ±º°ú ±³Á¤·ÂÀ» Àû¿ëÇÏÁö ¾ÊÀº ±ºÀÇ Á¦°ÅȸÀü·Â ÃøÁ¤°ú Á¶Á÷ÇÐÀû ºÐ¼®À» ÅëÇØ Áï½Ã ±³Á¤·ÂÀ» °¡ÇÑ ¹Ì´Ï½ºÅ©·ùÀÇ °íÁ¤¿øÀ¸·Î¼­ÀÇ ¾ÈÁ¤¼ºÀ» È®ÀÎÇÏ¿© ½Ä¸³ ÈÄ ±³Á¤·ÂÀ» Àû¿ë ¼ö ÀÖ´Â ½Ã±âÀÇ ¼±Åÿ¡ µµ¿òÀ» ÁÖ°íÀÚ ÇÏ´Â °ÍÀÌ´Ù. ¿Ü°æ 1.6 mm. ±æÀÌ 8 mmÀÎ ÃÑ 40°³ÀÇ Å¸ÀÌŸ´½ ¹Ì´Ï½ºÅ©·ù¸¦ 10¸¶¸® °¡ÅäÀÇ °æ°ñ¿¡ ½Ä¸³ÇÏ¿´´Ù. 20°³ÀÇ ¹Ì´Ï½ºÅ©·ù ½ÇÇ豺Àº ½Ä¸³ Á÷ÈĺÎÅÍ 6ÁÖ µ¿¾È Áö¼ÓÀûÀÎ 200gÀÇ ±³Á¤·ÂÀ» Àû¿ëÇÏ¿´°í ³ª¸ÓÁö 20°³ÀÇ ¹Ì´Ï½ºÅ©·ù ´ëÁ¶±ºÀº ±³Á¤·ÂÀ» Àû¿ëÇÏÁö ¾Ê¾Ò´Ù. Á¦°Å ȸÀü·ÂÀº µðÁöÅÐ ÅäÅ© °ÔÀÌÁö¸¦ ÀÌ¿ëÇÏ¿© ÃøÁ¤ÇÏ¿´À¸¸ç t-test¸¦ ÀÌ¿ëÇÏ¿© Åë°èó¸® ÇÏ¿´°í, Á¶Á÷Ç¥º»Àº ¹Ì´Ï½ºÅ©·ù¸¦ Á¦°ÅÇÑ ÈÄ H-E ¿°»öÇÏ¿© Á¶Á÷ ¼Ò°ßÀ» °üÂûÇÏ¿´´Ù. Á¦°ÅȸÀü·ÂÀº ½ÇÇ豺°ú ´ëÁ¶±º¿¡¼­ Åë°èÇÐÀûÀ¸·Î À¯ÀǼº ÀÖ´Â Â÷À̸¦ º¸ÀÌÁö ¾Ê¾ÒÀ¸¸ç, Á¶Á÷ÇÐÀûÀ¸·Î µÎ ±º°£ÀÇ Â÷ÀÌ´Â ¾ø¾ú´Ù. º» ¿¬±¸ÀÇ °á°ú´Â ±³Á¤¿ë ¹Ì´Ï½ºÅ©·ù¿¡ Áï½Ã ±³Á¤·ÂÀ» °¡ÇÏ´õ¶óµµ ¾ÈÁ¤ÀûÀÎ °íÁ¤¿øÀ¸·Î È°¿ë ÇÒ ¼ö ÀÖ´Ù´Â Á¡À» Á¦½ÃÇÑ´Ù.

The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model.

Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed.

Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups.

Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.