Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¹Ì´ÏÇ÷¹ÀÌÆ®ÀÇ °ñ³» °íÁ¤¿ø Àû¿ë ½Ã Ãʱ⠾ÈÁ¤¼º¿¡ ¿µÇâÀ» ÁÖ´Â ¿äÀο¡ ´ëÇÑ 3Â÷¿ø À¯ÇÑ¿ä¼Ò¹ýÀû ¿¬±¸

Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis

Korean Journal of Orthodontics 2008³â 38±Ç 5È£ p.304 ~ 313
À̳²±â, ÃÖµ¿¼ø, ÀåÀλê, Â÷ºÀ±Ù,
¼Ò¼Ó »ó¼¼Á¤º¸
À̳²±â ( Lee Nam-Ki ) - °­¸ª´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç
ÃÖµ¿¼ø ( Choi Dong-Soon ) - °­¸ª´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç
ÀåÀλê ( Jang In-San ) - Japan Nagasaki University Graduate School Department of Orthodontics
Â÷ºÀ±Ù ( Cha Bong-Keun ) - °­¸ª´ëÇб³ Ä¡°ú´ëÇÐ ±³Á¤Çб³½Ç

Abstract

º» ¿¬±¸´Â °ñ³» °íÁ¤¿øÀ¸·Î »ç¿ëÇÏ´Â ¹Ì´ÏÇ÷¹ÀÌÆ® ½Ã½ºÅÛÀÇ Ãʱ⠾ÈÁ¤¼º¿¡ ¿µÇâÀ» ÁÖ´Â ¿äÀο¡ ´ëÇØ ¾Ë¾Æº¸±â À§ÇØ ½ÃÇàÇÏ¿´´Ù. ¹Ì´ÏÇ÷¹ÀÌÆ®ÀÇ °íÁ¤¿¡ »ç¿ëµÇ´Â ¹Ì´Ï½ºÅ©·ùÀÇ ±æÀÌ, ¼ö ¹× Àû¿ëµÇ´Â ±³Á¤·ÂÀÇ ¹æÇâ¿¡ µû¸¥ °ñ³» ÀÀ·Â ºÐÆ÷ ¾ç»ó°ú ¹Ì´Ï½ºÅ©·ùÀÇ º¯À§ Á¤µµ¸¦ ºÐ¼®Çϱâ À§ÇÏ¿© 3Â÷¿ø À¯ÇÑ¿ä¼ÒºÐ¼®À» ½ÃÇàÇÏ¿´´Ù. ´Ü¼øÈ­ÇÑ °ñ ¸ðµ¨¿¡ 6 holeÀÇ °î¼±Çü ¹Ì´ÏÇ÷¹ÀÌÆ®¸¦ À§Ä¡ÇÏ°í Á÷°æ 2 mmÀÇ ¹Ì´Ï½ºÅ©·ù·Î °íÁ¤Ç쵂 °¢°¢ 6 mm¿Í 4 mm ±æÀÌÀÇ µÎ °¡Áö Á¾·ù·Î ¼¼ °³ ¶Ç´Â µÎ °³·Î °íÁ¤ÇÑ ÃÑ ³× °³ÀÇ À¯ÇÑ¿ä¼Ò¸ðµ¨À» Á¦ÀÛÇÑ ÈÄ °¢°¢ÀÇ ¸ðµ¨¿¡¼­ 4 NÀÇ ±³Á¤·ÂÀ» ¹Ì´ÏÇ÷¹ÀÌÆ®ÀÇ °íÁ¤µÇÁö ¾ÊÀº(unfixed) °¡Àå ¿ø½ÉÃø µÎ °³ÀÇ holeÀ» ¿¬°áÇÑ °¡»óÀÇ Ãà¿¡ ´ëÇØ 0o, 30o, 60o, 90o ¹æÇâÀ¸·Î °¢°¢ Àû¿ëÇÏ¿´´Ù. ¹Ì´ÏÇ÷¹ÀÌÆ®¸¦ °íÁ¤ÇÏ´Â ¹Ì´Ï½ºÅ©·ù°¡ µ¿ÀÏ ±æÀÌÀÏ °æ¿ì °³¼ö°¡ ÀÛÀ»¼ö·Ï, µ¿ÀÏ °³¼öÀÏ °æ¿ì ±æÀÌ°¡ ªÀ»¼ö·Ï °ñ¿¡ ³ªÅ¸³ª´Â ÃÖ´ë ÀÀ·Â°ú ¹Ì´Ï½ºÅ©·ùÀÇ ÃÖ´ë º¯À§°¡ Áõ°¡µÇ¾ú´Ù. °ñ¿¡ ³ªÅ¸³ª´Â ÃÖ´ë ÀÀ·ÂÀº Çظé°ñ¿¡ ºñÇØ ÇÇÁú°ñ¿¡ ÁýÁߵǾî ÀÀ·ÂÀÇ ´ëºÎºÐÀº ÇÇÁú°ñ¿¡¼­ Èí¼öµÇ¾ú´Ù. ¹Ì´ÏÇ÷¹ÀÌÆ®ÀÇ °¡»óÀÇ Ãà¿¡ ´ëÇØ ±³Á¤·ÂÀÇ °ßÀÎ ¹æÇâÀÌ Áõ°¡ÇÒ¼ö·Ï °ñ³»ÀÇ ÃÖ´ë ÀÀ·Â°ú ¹Ì´Ï½ºÅ©·ùÀÇ ÃÖ´ë º¯À§°¡ Áõ°¡µÇ¾ú´Ù. °ñ³»ÀÇ ÃÖ´ë ÀÀ·Â°ú ¹Ì´Ï½ºÅ©·ùÀÇ ÃÖ´ë º¯À§´Â Àû¿ëµÈ °ßÀη ÁöÁ¡¿¡¼­ °¡Àå °¡±î¿î ¹Ì´Ï½ºÅ©·ù °íÁ¤ ºÎÀ§¿´´Ù. ÀÌ»óÀÇ °á°ú·Î ¹Ì´ÏÇ÷¹ÀÌÆ® ½Ã½ºÅÛÀÇ Ãʱ⠾ÈÁ¤¼ºÀ» À§ÇØ 2 mm Á÷°æÀÇ ¹Ì´Ï½ºÅ©·ù¸¦ »ç¿ë ½Ã 4 mmº¸´Ù´Â 6 mm ±æÀÌÀÇ ¹Ì´Ï½ºÅ©·ù¸¦, 2°³º¸´Ù´Â 3°³ ½Ä¸³ÇÏ´Â °ÍÀÌ ´õ À¯¸®Çϸç, ¹Ì´ÏÇ÷¹ÀÌÆ®ÀÇ °¡»óÀÇ Ãà¿¡ ´ëÇØ Àû¿ëÇÏ´Â ±³Á¤·ÂÀÇ °ßÀιæÇâÀÌ °¡±ÞÀû ÀÏÄ¡µÇµµ·Ï ¹Ì´ÏÇ÷¹ÀÌÆ®¸¦ À§Ä¡½ÃÅ°´Â °ÍÀÌ ÁÁÀ» °ÍÀ¸·Î »ý°¢µÈ´Ù. (´ëÄ¡±³Á¤Áö 2008;38(5):304-313)

Objective: The purpose of this study was to evaluate the stress distribution in bone and displacement distribution of the miniscrew according to the length and number of the miniscrews used for the fixation of miniplate, and the direction of orthodontic force.

Methods: Four types of finite element models were designed to show various lengths (6 mm, 4 mm) and number (3, 2) of 2 mm diameter miniscrew used for the fixation of six holes for a curvilinear miniplate. A traction force of 4 N was applied at 0o, 30o, 60o and 90o to an imaginary axis connecting the two most distal unfixed holes of the miniplate.

Results: The smaller the number of the miniscrew and the shorter the length of the miniscrew, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. Most von Mises stress in the bone was absorbed in the cortical portion rather than in the cancellous portion. The more the angle of the applied force to the imaginary axis increased, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. The maximum von Mises stress in the bone and maximum displacement of the miniscrew were measured around the most distal screw-fixed area.

Conclusions: The results suggest that the miniplate system should be positioned in the rigid cortical bone with 3 miniscrews of 2 mm diameter and 6 mm length, and its imaginary axis placed as parallel as possible to the direction of orthodontic force to obtain good primary stability. (Korean J Orthod 2008;38(5):304-313)

Å°¿öµå

¹Ì´ÏÇ÷¹ÀÌÆ® ½Ã½ºÅÛ;°ñ³» °íÁ¤¿ø;Ãʱ⠾ÈÁ¤¼º;À¯ÇÑ ¿ä¼Ò ºÐ¼®
Miniplate;Anchorage;Primary stability;Finite element analysis

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

SCI(E)
KCI
KoreaMed