Effect of thermocycling on shear bond strength and mode of failure of ceramic orthodontic brackets bonded to different porcelain restorations

Korean Journal of Orthodontics 2009³â 39±Ç 4È£ p.225 ~ 233
°­»ó¿í, ±è¼º½Ä, ¹Ú¼öº´, ¼Õ¿ì¼º,
¼Ò¼Ó »ó¼¼Á¤º¸
°­»ó¿í ( Kang Sang-Wook ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°ú±³Á¤Çб³½Ç
±è¼º½Ä ( Kim Seong-Sik ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°ú±³Á¤Çб³½Ç
¹Ú¼öº´ ( Park Soo-Byung ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°ú±³Á¤Çб³½Ç
¼Õ¿ì¼º ( Son Woo-Sung ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°ú±³Á¤Çб³½Ç

Abstract

º» ¿¬±¸´Â µµÀç ¼öº¹¹°¿¡ ºÎÂøµÈ ´Ü°áÁ¤ ¼¼¶ó¹Í ºê¶óÄÏÀÇ Àü´ÜÁ¢Âø°­µµ¿Í ÆÄÀý¾ç»ó¿¡ ¿­¼øȯ°ú µµÀç ¼öº¹¹°ÀÇ Á¾·ù°¡ ¾î¶² ¿µÇâÀ» ¹ÌÄ¡´ÂÁö ¾Ë¾Æº¸±â À§ÇØ ½ÃÇàµÇ¾ú´Ù. µµÀçÀüÀå°ü¿¡ »ç¿ëµÇ´Â Àç·áµé Áß Ceramco 3, Empress II, Zi-ceram/Vintage ZR ¼¼ °¡Áö¸¦ ¼±ÅÃÇÏ¿© °¢ 20°³¾¿ ÃÑ 60°³ÀÇ ½ÃÆíÀ» ¿ø¹ÝÇüÅÂ(µÎ²² 2 mm, Á÷°æ 12 mm)·Î Á¦ÀÛÇÏ¿´´Ù. µ¿ÀÏÇÑ Á¢Âø ¼ú½ÄÀ¸·Î ¼¼¶ó¹Í ºê¶óÄÏÀ» ºÎÂøÇÑ ÈÄ ¿­¼øȯÀ» ½ÃÇàÇÑ ½ÇÇ豺°ú ½ÃÇàÇÏÁö ¾ÊÀº ´ëÁ¶±º, µÎ ±ºÀ¸·Î ³ª´©¾î Àü´ÜÁ¢Âø°­µµ¿Í ÆÄÀý¾ç»óÀ» Æò°¡ÇÏ¿´´Ù. ¿­¼øȯÀ» ÇÏÁö ¾ÊÀº ´ëÁ¶±ºÀÇ Àü´ÜÁ¢Âø°­µµ´Â Ceramco 3´Â 7.06 ¡¾ 1.76 MPa, Empress II´Â 7.55 ¡¾ 2.38 MPa ±×¸®°í Zi-ceram/Vintage ZRÀº 7.19 ¡¾ 1.38 MPa·Î ÃßõµÇ´Â Àü´ÜÁ¢Âø°­µµ(6 - 8 MPa)¿¡ ÀûÇÕÇÑ °­µµ¸¦ º¸¿´À¸³ª ¿­¼øȯÀ» ½ÃÇàÇÑ ½ÇÇ豺Àº Àü´ÜÁ¢Âø°­µµ°¡ À¯ÀÇÇÏ°Ô °¨¼ÒÇÏ¿´À¸¸ç(p £¼ 0.05) ¿­¼øȯ ÈÄÀÇ Àü´ÜÁ¢Âø°­µµ´Â Ceramco 3´Â 4.88 ¡¾ 1.00 MPa, Empress II´Â 5.46 ¡¾ 1.35 MPa ±×¸®°í Zi-ceram/Vintage ZRÀº 4.84 ¡¾ 1.01 MPa·Î ÀÓ»óÀûÀ¸·Î ÃßõµÇ´Â °Íº¸´Ù ´Ù¼Ò ³·Àº °ªÀ» º¸¿´´Ù. µµÀçÀÇ Á¾·ù¿¡ µû¸¥ Àü´ÜÁ¢Âø°­µµ¿¡´Â À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾ú´Ù. ÆÄÀý¾ç»óÀº ´ëÁ¶±º¿¡¼­´Â ¸ðµÎ ºê¶óÄÏ ±âÀúºÎ¿Í Á¢ÂøÁ¦ »çÀÌ¿¡¼­ ÆÄÀýÀÌ ÀϾÀ¸¸ç, ½ÇÇ豺¿¡¼­´Â 2°³ÀÇ ½ÃÆí(Ceramco 3°ú Zi-ceram/Vintage ZR±º¿¡¼­ °¢ 1°³)¸¸ÀÌ Á¢ÂøÁ¦³» ÆÄÀýÀ» º¸¿´À¸¸ç 28°³ÀÇ ½ÃÆíÀº ºê¶óÄÏ ±âÀúºÎ¿Í Á¢ÂøÁ¦ »çÀÌ¿¡¼­ ÆÄÀýÀÌ ÀϾ´Ù. ÀÌ»óÀÇ ¿¬±¸ °á°ú¿¡¼­ º¸¾ÒÀ» ¶§ µµÀç ¼öº¹¹°ÀÇ Á¾·ù¿¡ µû¸¥ Â÷ÀÌ´Â ¾ø¾úÀ¸³ª ¿­¼øȯ¿¡ ÀÇÇØ Àü´ÜÁ¢Âø°­µµ°¡ ¾àÈ­µÇ¹Ç·Î ½ÇÁ¦ ÀÓ»ó¿¡¼­ °í·ÁµÇ¾î¾ß ÇÒ °ÍÀÌ´Ù.

Objective: The purpose of this study was to investigate the effect of thermocycling and type of porcelain restoration on shear bond strength (SBS) and mode of failure of monocrystalline ceramic brackets.

Methods: A total of 60 porcelain discs were made and divided into three equal groups as follows: Ceramco 3, IPS Empress II, Zi-ceram/Vintage ZR. ceramic brackets were bonded to the prepared porcelain surfaces in the same manner. Each group was divided randomly into two subgroups: thermocycled group and non-thermocycled group (control). All samples were tested in shear mode on an universal testing machine.

Results: SBS of the non-thermocycled group was clinically acceptable (Ceramco 3: 7.06 ¡¾ 1.76 MPa, IPS Empress II: 7.55 ¡¾ 2.38 MPa, Zi-ceram/Vintage ZR: 7.19 ¡¾ 1.38 MPa). But, SBS of the thermocycled group was significantly reduced (Ceramco 3: 4.88 ¡¾ 1.00 MPa, IPS Empress II: 5.46 ¡¾ 1.35 MPa, Zi-ceram/Vintage ZR: 4.84 ¡¾ 1.01 MPa, p £¼ 0.05). There was no difference between the shear bond strength by type of porcelain restoration. All bonding failure occurred between bracket base and adhesive, except for 2 samples.

Conclusions: The results of this study suggest that the type of porcelain restoration did not affect SBS, but thermocycling weakened SBS. Therefore, the effect of thermocycling should be considered when using ceramic brackets in practice.

Å°¿öµå

¿­¼øȯ;¼¼¶ó¹Í ºê¶óÄÏ;Àü´ÜÁ¢Âø°­µµ
Thermocycling;Ceramic bracket;Shear bond strength