3Â÷¿ø ·¹ÀÌÀú ½ºÄµ¿µ»ó äµæ ½Ã ½ºÄµ°¢µµ¿Í Ƚ¼ö¿¡ µû¸¥ Á¤È®µµ

Influence of the angles and number of scans on the accuracy of 3D laser scanning

Korean Journal of Orthodontics 2011³â 41±Ç 2È£ p.76 ~ 86
ÀÌ°æ¹Î, ¼ÛÈ¿¿µ, À̱âÇå, ȲÇý³²,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌ°æ¹Î ( Lee Kyung-Min ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ±³Á¤Çб³½Ç
¼ÛÈ¿¿µ ( Song Hyo-Young ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ±³Á¤Çб³½Ç
À̱âÇå ( Lee Ki-Heon ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ±³Á¤Çб³½Ç
ȲÇý³² ( Hwang Hye-Nam ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø ±³Á¤Çб³½Ç

Abstract

º» ¿¬±¸´Â 3Â÷¿ø ·¹ÀÌÀú ½ºÄ³³Ê¸¦ ÀÌ¿ëÇÏ¿© ¾È¸é ÀÔü¿µ»óÀ» À籸¼ºÇÒ ¶§ ½ºÄµ°¢µµ¿Í Ƚ¼ö¿¡ µû¸¥ ÀÔü¿µ»óÀÇ Á¤È®µµ¸¦ Æò°¡ÇÏ°íÀÚ ½ÃÇàµÇ¾ú´Ù. »ç¶÷ÀÇ ¾ó±¼Çü»óÀ» ÇÑ µÎºÎ ¸¶³×Å· 10°³¸¦ ´ë»óÀ¸·Î ¾È¸é¿¡ ¸¶Ä¿¸¦ ºÎÂøÇÏ°í ºñÁ¢ÃË½Ä 3Â÷¿ø ·¹ÀÌÀú ½ºÄ³³Ê¸¦ ÀÌ¿ëÇÏ¿© Á¤¸é, Á¤¸é¿¡ ´ëÇØ °¢°¢ Á¿ì 20µµ, 45µµ, 60µµ Ãø¹æ¸éÀ» ½ºÄµÇÏ°í Á¿ì 20µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 2°¡Áö ¿µ»ó, Á¤¸é°ú Á¿ì 20µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 3°¡Áö ¿µ»ó, Á¿ì 45µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 2°¡Áö ¿µ»ó, Á¤¸é°ú Á¿ì 45µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 3°¡Áö ¿µ»ó, Á¤¸é°ú Á¿ì 60µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 3°¡Áö ¿µ»ó, Á¤¸é°ú Á¿ì 20µµ, 60µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ 5°¡Áö ¿µ»ó µî 6°¡Áö ¹æ¹ýÀ¸·Î 3Â÷¿ø ¿ª¼³°è ¼ÒÇÁÆ®¿þ¾î ÇÁ·Î±×·¥À» ÀÌ¿ëÇÏ¿© À籸¼ºÇÑ ´ÙÀ½ °¢ ¹æ¹ý¿¡ µû¸¥ ÀÔü¿µ»ó¿¡¼­ ¸¶Ä¿°£ °Å¸®¸¦ ÃøÁ¤ÇÏ°í ¸¶³×Å·¿¡¼­ÀÇ ½ÇÃøÄ¡¿Í ºñ±³ÇÏ¿´´Ù. ¸¶³×Å· ½ÇÃøÄ¡¿¡ ´ëÇÑ ·¹ÀÌÀú ½ºÄµ¿µ»ó °èÃøÄ¡ÀÇ È®´ëÀ²Àº 0.14 - 0.26%·Î ³ªÅ¸³µ´Ù. Á¿ì 20µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ °æ¿ì, Á¤¸é°ú Á¿ì 20µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ °æ¿ì¿Í Á¿ì 45µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ °æ¿ì´Â ¿©·¯ °èÃøÄ¡°¡ ½ÇÃøÄ¡¿Í Â÷À̸¦ º¸ÀÎ ¹Ý¸é, Á¤¸é°ú Á¿ì 45µµ ȤÀº Á¤¸é°ú Á¿ì 60µµ Ãø¹æ¸éÀ» ½ºÄµÇÑ °æ¿ì¿Í Á¤¸é°ú Á¿ì 20µµ¿Í 60µµ¸¦ ½ºÄµÇÑ °æ¿ì´Â ÇÑ °èÃøÄ¡(Pn-Pg¡¯)¸¦ Á¦¿ÜÇÑ ¸ðµç °èÃøÇ׸ñ¿¡¼­ ½ÇÃøÄ¡¿Í Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷À̸¦ º¸ÀÌÁö ¾Ê¾Ò´Ù. º» ¿¬±¸ °á°ú´Â ½ºÄµ°¢µµ¿Í Ƚ¼ö°¡ ¾È¸é ÀÔü¿µ»óÀÇ Á¤È®µµ¿¡ ¿µÇâÀ» ¹ÌÄ¡´Â °ÍÀ» ÀǹÌÇϸç Á¤È®ÇÑ À籸¼ºÀ» À§Çؼ­´Â Á¿ì 45µµ ÀÌ»óÀÇ Ãø¹æ¸éÀ» ½ºÄµÇÏ´Â °ÍÀÌ, ±×¸®°í Á¤¸éÀ» Æ÷ÇÔÇÏ¿© ÃÖ¼Ò 3°³ÀÇ ¿µ»óÀ» ÀÌ¿ëÇÏ¿© ÇÕ¼ºÇÏ´Â °ÍÀÌ ¹Ù¶÷Á÷ÇÔÀ» ½Ã»çÇÏ¿´´Ù.

Objective : To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans.

Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at 20o, 45o, and 60o angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins.

Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at 20¡Æ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at 20o and 60o on both sides; only 1 measurement was significantly different.

Conclusions : These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than 45o on both sides, should be integrated to obtain accurate 3D facial images.

Å°¿öµå

3D laser scanner; Scan angle; Number of scans