Comparison of dimensional accuracy between direct-printed and thermoformed aligners

Korean Journal of Orthodontics 2022³â 52±Ç 4È£ p.249 ~ 257
Koenig Nickolas, ÃÖÁø¿µ, McCray Julie, Hayes Andrew, Schneider Patricia, ±è±â¹ü,
¼Ò¼Ó »ó¼¼Á¤º¸
 ( Koenig Nickolas ) - Saint Louis University Department of Orthodontics
ÃÖÁø¿µ ( Choi Jin-Young ) - Kyung Hee University Graduate School of Dentistry Department of Orthodontics
 ( McCray Julie ) - Saint Louis University Department of Orthodontics
 ( Hayes Andrew ) - Saint Louis University Department of Orthodontics
 ( Schneider Patricia ) - Saint Louis University Department of Orthodontics
±è±â¹ü ( Kim Ki-Beom ) - Saint Louis University Department of Orthodontics

Abstract


Objective: The purpose of this study was to evaluate and compare the dimensional accuracy between thermoformed and direct-printed aligners.

Methods: Three types of aligners were manufactured from the same reference standard tessellation language (STL) file: thermoformed aligners were manufactured using Zendura FLXTM (n = 12) and Essix ACETM (n = 12), and direct-printed aligners were printed using Tera HarzTM TC-85DAP 3D Printer UV Resin (n = 12). The teeth were not manipulated with any tooth-moving software in this study. The samples were sprayed with an opaque scanning spray, scanned, imported to Geomagic¢ç Control XTM metrology software, and superimposed on the reference STL file by using the best-fit alignment algorithm. Distances between the aligner meshes and the reference STL file were measured at nine anatomical landmarks.

Results: Mean absolute discrepancies in the Zendura FLXTM aligners ranged from 0.076 ¡¾ 0.057 mm to 0.260 ¡¾ 0.089 mm and those in the Essix ACETM aligners ranged from 0.188 ¡¾ 0.271 mm to 0.457 ¡¾ 0.350 mm, while in the direct-printed aligners, they ranged from 0.079 ¡¾ 0.054 mm to 0.224 ¡¾ 0.041 mm. Root mean square values, representing the overall trueness, ranged from 0.209 ¡¾ 0.094 mm for Essix ACETM, 0.188 ¡¾ 0.074 mm for Zendura FLXTM, and 0.140 ¡¾ 0.020 mm for the direct-printed aligners.

Conclusions: This study showed greater trueness and precision of direct-printed aligners than thermoformed aligners.

Å°¿öµå

Aligner; Physical property; Resin; Three-dimensional scanner