The gaps between the die margin worked and the casting body were measured with an optical microscope and compared after making crown prosthetic materials using three kinds of die material - dental stone, extra hard stone, epoxy resin - used in crown prosthesis. The results are as follows : 1. All the gaps between the cast cervical margin and the casting bodies were relatively good regardless of die materials used with the gaps under , the allowable limit. 2. The cervical margin suitability of epoxy resin die was the highest among the three kinds of die material with the suitability value of . 3. Among the four surfaces(buccal, lingual, mesial, distal) of all the casting bodies, buccal surface was the highest in the cervical margin suitability with the value of .