Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ti-Pd°è ÇÕ±ÝÀÇ ¹Ì¼¼Á¶Á÷º¯È­¿¡ µû¸¥ ºÎ½Ä°Åµ¿

Corrosion Behavior of Ti-Pd System Alloys by Microstructural changes

´ëÇÑÄ¡°ú±â°øÇÐȸÁö 2008³â 30±Ç 2È£ p.9 ~ 16
Â÷¼º¼ö, °ûµ¿ÁÖ, ³²»ó¿ë,
¼Ò¼Ó »ó¼¼Á¤º¸
Â÷¼º¼ö ( Cha Sung-Soo ) - ÁøÁÖº¸°Ç´ëÇÐ Ä¡±â°ø°ú
°ûµ¿ÁÖ ( Kwak Dong-Ju ) - ´ë±¸º¸°Ç´ëÇÐ Ä¡±â°ø°ú
³²»ó¿ë ( Nam Sang-Yong ) - ´ë±¸º¸°Ç´ëÇÐ Ä¡±â°ø°ú

Abstract


The surface microstructural changes, mechanical properties and corrosion resistance of Ti-Pd alloys for dental biomaterials have been investigated. Ti, Ti-Pd alloys were melted in arc furnace and the corrosion resistance of Ti-Pd alloys was evaluated by anodic polarization test. The surface microstructural changes and mechanical properties of Ti-Pd alloys were analysed by scanning electron microscope and Vickers micro-hardness tester. The vickers hardnees of pure Ti improved by addition of Pd but Ti-25Pd alloy showed decreasing compared with Ti-15Pd. And anodic polarization and potentiostatic test were conducted in 5% HCl to quantify the resistance to corrosion with the addition of Pd, There was no significant difference in corrosion resistance between pure Ti, Ti-5Pd and Ti-15Pd alloy. However, Ti-25Pd alloy showed decreasing compared with pure Ti in corrosion resistance. From these results, it was concluded that newly formulated Ti-15Pd experimental alloy have adequate hardness and high corrosion resistance, and this alloy is promising candidate for a successful dental casting alloy.

Å°¿öµå

Corrosion behavior; micro-hardness; Titanium alloys; Ti-Pd alloy; Ti-Pd microstructure

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

µîÀçÀú³Î Á¤º¸

KCI