A Study of Bonding Strength of Repaired Resin Denture Base by Artificial Saliva Absorption

´ëÇÑÄ¡°ú±â°øÇÐȸÁö 2011³â 33±Ç 1È£ p.25 ~ 35
°­¸íÈ£, À̸í°ï,
¼Ò¼Ó »ó¼¼Á¤º¸
°­¸íÈ£ ( Kang Myung-Ho ) - ±âÃÌÄ¡°ú±â°ø¼Ò
À̸í°ï ( Lee Myung-Kon ) - ºÎ»ê°¡Å縯´ëÇб³ º¸°Ç°úÇдëÇÐ Ä¡±â°øÇаú

Abstract


Purpose: There are some advantages of the acrylic resin denture base ; appropriate strength, volume safety, simple processing apparatus, and low cost. But, it have a weakness for fracture by intense pressure or shock. However, the repairs for resin denture base are possible using various materials and techniques. There is a few studies in repairs for resin denture base, but not clinical researches. And there is no studies in absorbed saliva into the region of fracture and bond strength. This study is to observe re-bond strength of resin denture base after repairing under saliva absorption.

Methods: The samples were made of heat curing resin and the rectangular parallelepiped specimens which were 50mm long, 10mm wide and 3mm high. The four different groups immersed in the artificial saliva for 2 weeks were prepared, 1) no repaired control samples, 2) immediately repaired samples, 3) repaired samples after 1 day dry, and 4) repaired samples after 3 days dry. The prepared samples were repaired by two different curing materials, self curing resin and heat curing resin method. Each groups composed of 10 specimens were experimented with the three point bending tests for bonding strength measuring.

Results: There were under condition absorbed in the artificial saliva and repaired by self curing resin method, repaired specimens after 1 day and 3 days dry groups had higher values of bonding strengths than control group, and bonding strengths of immediately repaired samples were similar to those of control samples (p<0.05). There were under condition immersed in the artificial saliva and repaired by heat curing resin method, immediately repaired samples showed similar values to bonding strengths of control groups, and repaired samples after 1 day and 3 days dry groups were lower than those of control group (p>0.05).

Conclusion: In this study, the repairs for resin denture base were remarkably high values of bonding strengths than those of the past, and showed that have stable bonding strengths independent of saliva absorption of denture base, so present repairs for resin denture base can be performed, regardless of saliva conditions.

Å°¿öµå

denture base resin; saliva absorption; bonding strength