The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry

´ëÇÑÄ¡°ú±â°øÇÐȸÁö 2012³â 34±Ç 2È£ p.83 ~ 93
ÀÌÁ¾È­, ¹Úõ¸¸, ¼ÛÀç»ó, Àӽôö, ±èÀçµµ, ±èº´½Ä, ȲÀÎȯ, À̼º±¹,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌÁ¾È­ ( Lee Jong-Hwa ) - °è¸í´ëÇб³ °øÁߺ¸°ÇÇаú
¹Úõ¸¸ ( Park Chun-Man ) - °è¸í´ëÇб³ °øÁߺ¸°ÇÇаú
¼ÛÀç»ó ( Song Jae-Sang ) - ±èõ´ëÇб³ Ä¡±â°ø°ú
Àӽôö ( Lim Si-Duk ) - ¼ö¼º´ëÇб³ Ä¡±â°ø°ú
±èÀçµµ ( Kim Jae-Do ) - ¼ö¼º´ëÇб³ Ä¡±â°ø°ú
±èº´½Ä ( Kim Byung-Sik ) - ¼ö¼º´ëÇб³ Ä¡±â°ø°ú
ȲÀÎȯ ( Hwang In-Whan ) - (ÁÖ)ºñÄÉÀÌ ¸Þ¸àÆ®
À̼º±¹ ( Lee Sung-Kuk ) - µ¿¿øÄ¡°ú±â°ø¼Ò

Abstract


Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low
temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown.

Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation ,and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics.

Results: The average density of the monolithic all-ceramic crown was 6.0280 0.0147g/cm, the relative density was 99.01 %. When the sample was sintered at 1480 the diameter of average particle was 396.62 33.71nm. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was 1747.40 ©¬A, at the temperature of 130 the flexural strength after the low temperature degradation was 1063.99 (p<0.001). There was statistically significant difference in the result of strength of 1020.07 after the low temperature degradation at the temperature of 200 (p<0.001).

Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental
restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.

Å°¿öµå

flexural strength; monolithic all-ceramic crown; TZP; zirconia block