Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ä¡°ú ÁÖÁ¶¿ë Co-Cr-Mo alloy¿¡¼­ ÀüÇØ¿ë¾× ¿Âµµ¿Í ÀüÇؽ𣿡 µû¸¥ ÀüÇØ¿¬¸¶ÀÇ Æ¯¼º

Effect of polishing solution temperature and times by electro-polishing in dental casting Co-Cr-Mo alloy

´ëÇÑÄ¡°ú±â°øÇÐȸÁö 2012³â 34±Ç 2È£ p.145 ~ 153
ÀåÀ翵, ¼ÛÀç»ó, ³ªÁ¤¼÷,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀåÀ翵 ( Jang Jae-Young ) - ±èõ´ëÇб³ Ä¡±â°ø°ú
¼ÛÀç»ó ( Song Jae-Sang ) - ±èõ´ëÇб³ Ä¡±â°ø°ú
³ªÁ¤¼÷ ( Nah Jung-Sook ) - ÁøÁÖº¸°Ç´ëÇÐ Ä¡±â°ø°ú

Abstract


Purpose: The purpose of this study was to investigate to effect of the electro-polishing condition according to
electrolyte temperature and current and polishing time on surface morphology and composition by scanning electron microscopy(SEM) and energy dispersive X-ray spectrometer(EDS) in dental casting Co-Cr-Mo alloys.

Methods: 16 specimens were divided into 4 groups which have each 4 specimens. The size of specimens were 10 wide and 5 height. the electro-polishing of specimens are by polishing solution temperature and times in Co-Cr-Mo alloy by SEM and EDS analysis.

Results: The results shows that most smooth surface is obtained when electro-polishing is performed at 49 for
30-40sec with electro gap of 10mm and 8 voltage.

Conclusion: The morphologies of specimens after electro-polishing were scratch absent and significant between at 40 for 45sec and at 49 for 45sec.

Å°¿öµå

electro-polishing solution; temperature; electron polishing time; surface morphology

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

µîÀçÀú³Î Á¤º¸

KCI