Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis

´ëÇÑÄ¡°ú±â°øÇÐȸÁö 2017³â 39±Ç 1È£ p.17 ~ 24
°­½Å¿µ, ¹ÚÁø¿µ, ±èµ¿¿¬, ±è¿õö,
¼Ò¼Ó »ó¼¼Á¤º¸
°­½Å¿µ ( Kang Seen-Young ) - °í·Á´ëÇб³ ´ëÇпø º¸°Ç°úÇаú
¹ÚÁø¿µ ( Park Jin-Young ) - °í·Á´ëÇб³ ´ëÇпø º¸°Ç°úÇаú
±èµ¿¿¬ ( Kim Dong-Yeon ) - °í·Á´ëÇб³ ´ëÇпø º¸°Ç°úÇаú
±è¿õö ( Kim Woong-Chul ) - °í·Á´ëÇб³ ´ëÇпø º¸°Ç°úÇаú

Abstract


Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the
traditional and Digital manufacturing methods through 3-dimensional analysis.

Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were
manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone
impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC
group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD).

Results: Three groups are measured 47.11¡¾(3.08)§­ total RMS of SLAC group, 48.35(¡¾1.55§­) for total RMS of LAPC
group, 43.45¡¾2.09§­ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized
pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321).

Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three?ways methods showed that no
differences statistically significant and clinically acceptable results.

Å°¿öµå

Light-activated pattern resin ; Autopolymerized pattern resin ; Stereolithography ; 3D-mensional analysis ; Coping