¼öÁ¾ Ä¡°ú¿ë ¾ËÁö³×ÀÌÆ® ÀλóÀç¿Í ¼®°í ¸ðÇüÀçÀÇ Ä£È¼º¿¡ °üÇÑ ½ÇÇèÀû ¿¬±¸
AN EXPERIMENTAL STUDIES FOR COMPATIBILITY OF SOME ALGINATE IMPRESS10N MATERIALS WITH GYPSUM PRODUCTS
¹èÇö°æ, ±è°æ³²,
¼Ò¼Ó »ó¼¼Á¤º¸
¹èÇö°æ ( ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ ¼Ò¾ÆÄ¡°úÇб³½Ç
±è°æ³² ( ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úÀç·áÇб³½Ç
KMID : 0362219870140010057
Abstract
°á·Ð
ÇöÀç ±¹³»¿¡¼ À¯ÅëµÇ°í ÀÖ´Â Ä¡°ú¿ë ¾ËÁö³×ÀÌÆ® ÀλóÀçÁÙ 8Á¾, ¼®°í ¸ðÇüÀçÁß 5Á¾À» ¼±
ÅÃÇÏ¿© ¼¼°èÇ¥Áرⱸ±Ô°Ý Á¦1563È£ ¹× ´ëÇÑÄ¡°úÀÇ»çÇùȸ±Ô°Ý Á¦8È£¿¡ ±ÔÁ¤µÈ ¼®°í ¸ðÇüÀç¿Í
ÀÇ Ä£È¼º ÃøÁ¤¹æ¹ýÀ» ÀÌ¿ë, ģȼºÀ» Æò°¡ÇÑ °á°ú, ´ÙÀ½°ú °°Àº °á·ÐÀ» ¾ò¾ú´Ù.
1. ½ÇÇè¿¡ »ç¿ëÇÑ ¾ËÁö³×ÀÌÆ® ÀλóÀç¿Í ¼®°í ¸ðÇüÀç´Â ´ëºÎºÐ 50¥ìm³ÐÀÌ ¼±À» ÀçÇöÇÏ¿´
´Ù.
2. ¹«ºÐÁøÇü¿¡¼´Â DE-YP°¡, Àç·¡Çü¿¡¼´Â KA-YP, -BH ; PA-YP, -GC ; CO-YP,-BH
;CA-SR, -YP, -GC°¡ ģȼºÀÌ °¡Àå ¿ì¼öÇß´Ù.
#ÃÊ·Ï#
The purpose of this study was to investigate the compatibility of some alginate
impression materials with gypsum products. 4 conventional alginate impression materials,
4 dust-free alginate impression materials, and 5 gypsum Products were used in this
study. Compatibility of alginate impression materials with gypsum Products were
evaluated according to ISO No. 1563 and Korean Dental Association specification No. 8.
The results were as follows:
1. Most of tested alginate impression materials and gypsum Products were reproduced
the 501m line except PF-SR.
2. DE-YP in dust-free alginate impression material and KA-YP, KA-BH, PA-YP,
PA-GC, CO-YP, CO-BH , CA-SR, CA-YP, and CA-GC in conventional alginate
impression materials were presented most excellent compatibility.
Å°¿öµå
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸