Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¼öÁ¾ ºÒ¼ÒÇÔÀ¯ ÀÌÀå¿ë ½Ã¸àÆ®ÀÇ ºÒ¼Ò À¯¸®·®°ú »ó¾ÆÁú·ÎÀÇ ºÒ¼ÒÈíÂøÁ¤µµ

THE IN VITRO STUDY ON FLUORIDE RELEASE AND FLUORKDE UPTAKE TO DENTIN FROM FLUORIDE CONTALNING LINER/BASE CEMENTS

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 1993³â 18±Ç 1È£ p.27 ~ 51
°íÈ¿Áö, ¾È±âÇö, ·®µ¿¿í,
¼Ò¼Ó »ó¼¼Á¤º¸
°íÈ¿Áö (  ) - Àü³²´ëÇб³
¾È±âÇö (  ) - Àü³²´ëÇб³
·®µ¿¿í (  ) - Àü³²´ëÇб³

Abstract


The purpose of this study was to determine the fluroide release levels of new fluoridecontaining liner/base cements and the fluoride uptake by dentin surfaces.
The specimens of each brand(Fuji ionomer. Type III, Fuji Lining LC, Timeline, Vitrebond and XR ionomer) were made, polymerized and placed in fluoride-free distilled water at 37¡É, 100% relative humidity for 24 hours. The extracting solution of
specimen
was exchanged and fluoride release was measured daily for the 30 days.
For fluoride uptake study, twenty-five extracted human lower molars were sectioned longitudinally in the mesiodistal direction with a diamond disc. Five teeth were filled with each material and then stored at 37¡É, 100% humidity for 4 weeks.
Fluoride
uptake by dentin from the test materials was evaluated using electron probe micro X-ray analyzer.
@ES The following results were obtained:
@EN 1. The amounts of fluoride release showed no significant difference between Fuji ionomer Type III and Fuji Lining. LC, but showed significant difference between other groups. XR ionomer released significantly greater fluoride than any other
group(P<0.001).
2. All the materials have a decrease over the test period (P<0.001).
3. XR ionomer group showed fluoride penetration to approximately 50¥ìm deep in dentin. But other material groups showed very little fluoride uptake by dentin.

Å°¿öµå

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI