Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¸¸°î±Ù°ü¿¡¼­ ±Ù°üÇü¼º¹ý¿¡ µû¸¥ ±Ù°üÀÛ¾÷ÀåÀÇ º¯È­

Change of working length in curved canals by various instrumentation techniques

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2006³â 31±Ç 1È£ p.30 ~ 35
¼ºÀçÇö, ¹Ú°æ´ö, ¼ºÀçÇö, ±è»óµÎ,
¼Ò¼Ó »ó¼¼Á¤º¸
¼ºÀçÇö (  ) - °æºÏ´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°úº¸Á¸Çб³½Ç
¹Ú°æ´ö (  ) - °æºÏ´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°úº¸Á¸Çб³½Ç
¼ºÀçÇö (  ) - °æºÏ´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°úº¸Á¸Çб³½Ç
±è»óµÎ (  ) - °æºÏ´ëÇб³ Ä¡ÀÇÇдëÇпø Ä¡°úº¸Á¸Çб³½Ç

Abstract

¸¸°î±Ù°ü¿¡¼­ ±Ù°üÇü¼º¹æ¹ý¿¡ µû¸¥ ±Ù°üÀÛ¾÷Àå º¯È­¸¦ Æò°¡Çϱâ À§ÇÏ¿© ¹ß°ÅµÈ ´ë±¸Ä¡ÀÇ ÇùÃø ¶Ç´Â ±Ù½É ±Ù°ü 40°³¿¡¼­ ½ºÅ×Àη¹½º-½ºÆ¿ ¼öµ¿ ÆÄÀÏ ($MANI^{(R)}$, ÀϺ»), ´ÏÄÌ-ƼŸ´½ ¼öµ¿ ÆÄÀÏ (Naviflex $NT^{TM}$, ¹Ì±¹), ProFile, ¶Ç´Â $ProTaper^{TM}$ (Dentsply-Maillefor, ½ºÀ§½º)¸¦ »ç¿ëÇÏ¿© crown-down ¹æ¹ýÀ¸·Î 30¹ø Å©±â±îÁö ±Ù°üÀ» Çü¼ºÇÏ°í ±Ù°üÇü¼º ÀüÈÄÀÇ ±Ù°üÀÛ¾÷Àå ¹× ¸¸°îµµÀÇ º¯È­¸¦ °üÂûÇÏ¿´´Ù. ±Ù´Ü°ø¿¡ ´ëÇÑ 10-KÆÄÀÏ ³¡ÀÇ À§Ä¡º¯È­¸¦ AutoCAD2000 (Autodesk »ç, ¹Ì±¹)À¸·Î ÃøÁ¤ÇÏ°í ÀÏ¿øº¯·®ºÐ¼®¹ý ¹× Tukey¡¯¡¯s studentized range test·Î Åë°è ºÐ¼®ÇÏ¿´´Ù. ¸ðµç ±º¿¡¼­ ±Ù°üÇü¼ºÈÄ ±Ù°üÀå ¹× ¸¸°îµµ°¡ À¯ÀÇÇÏ°Ô °¨¼ÒÇÏ¿´À¸¸ç, Ä¡°üºÎ ±Ù°üÇü¼º½Ã Gates Glidden bur¸¦ »ç¿ëÇÑ ¼öµ¿ÆÄÀÏ ±ºÀÌ ProFile ±ºº¸´Ù À¯ÀÇÇÏ°Ô ¸¹Àº ±Ù°üÀå °¨¼Ò¸¦ ÃÊ·¡ÇÏ¿´°í, Ä¡°üºÎ ¹× ±Ù´ÜºÎ Àüü ±Ù°üÇü¼ºÈÄ¿¡´Â ½ºÅ×Àη¹½º ½ºÆ¿ ¼öµ¿ÆÄÀÏ ±ºÀÌ ProFile ±º¿¡¼­º¸´Ù À¯ÀÇÇÏ°Ô ¸¹Àº ±Ù°üÀå °¨¼Ò¸¦ ³ªÅ¸³»¾ú´Ù (p<0.05).

To evaluate the change of working length with various instrumentation techniques in curved canals, working length and canal curvature were determined before and after canal instrumentation in buccal or mesial canals of extracted human molars. Stainless steel K-files ($MANI^{(R)}$, Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex $NT^{TM}$, Brassier, Savannah, USA) , $ProFile^{(R)}$, and ProTaper (Dentsply-Maillefer, Ballaigues, Switzerland) were used to prepare the canals with crown-down technique. In two hand instrumentation groups coronal flaring was made with Gates Glidden burs. Apical canals were instrumented until apical diameter had attained a size of 30. Positional relation between the tooth apex and the $\#10$ K-file tip was examined by using AutoCAD 2000 (Autodesk Corp., San Rafael. CA, USA) under a stereomicroscope before and after coronal flaring, and after apical instrumentation. Degree of canal curvature was also measured with Schneider¡¯¡¯s method in radiographs. Data of working length and canal curvature changes were statistically analyzed with one-way ANOVA and Tukey¡¯¡¯s studentized range test. Working length and canal curvature were decreased significantly in each step in all instrumentation groups. Coronal flaring using Cates Glidden burs in hand instrument groups and whole canal instrumentation using stainless steel hand K-files caused significantly more working length change than in ProFile instrumentation group (p<0.05). The result of this study demonstrates that all of the above kinds of instrumentation in curved canals cause reduction of working length and canal curvature at each instrumentation steps, and hand instrumentation causes more working length change than ProFile.

Å°¿öµå

±Ù°üÀÛ¾÷Àå;¸¸°î±Ù°ü;¼öµ¿±â±¸ Àüµ¿±â±¸;±Ù°ü¸¸°î;Working length;Curved canal;Hand instrumentation;Rotary instrumentation;ProFile;Canal curvature

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI