Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Continuous wave of obturation technique¿¡¼­ Ç÷¯°ÅÀÇ ´Ù¾çÇÑ Àû¿ë ±íÀÌ¿¡ µû¸¥ ±Ù´ÜºÎ Æó¼âÈ¿À² ºñ±³

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2007³â 32±Ç 6È£ p.491 ~ 497
ÀÌ»óÁø, ¹ÚÁ¤±æ, Ç㺹, ±èÇöö,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌ»óÁø ( Lee Sang-Jin ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Á¸Çб³½Ç
¹ÚÁ¤±æ ( Park Jeong-Kil ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Á¸Çб³½Ç
Ç㺹 ( Hur Bock ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Á¸Çб³½Ç
±èÇöö ( Kim Hyeon-Cheol ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Á¸Çб³½Ç

Abstract

ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº continuous wave of obturation techniqueÀ¸·Î ±Ù°ü ÃæÀüÀ» ÇÒ ¶§, ´Ù¾çÇÑ heat source pluggerÀÇ ±íÀÌ¿¡ µû¸¥ ±Ù´ÜºÎ ±Ù°ü Æó¼â´É·ÂÀ» ºñ±³ÇÏ´Â °ÍÀ̾ú´Ù. Á÷¼± ÇüÅ ¹ß°Å ¼Ò±¸Ä¡¸¦ 35/.06 Å©±â±îÁö ´ÏÄÌƼŸ´½ ÆÄÀÏÀ» »ç¿ëÇÏ¿© ¼ºÇü ¹× ¼¼Á¤ÇÏ¿´´Ù. ¼ºÇü°ú ¼¼Á¤ÀÌ ¿Ï·áµÈ Ä¡¾Æ¸¦ heat source pluggerÀÇ Àû¿ë ±íÀÌ¿¡ µû¶ó 15°³¾¿ 5±ºÀ¸·Î ºÐ·ùÇÏ¿´´Ù. 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, ¾ç¼º ´ëÁ¶±ºÀ» Á¦¿ÜÇÑ ¸ðµç ±Ù°üÀº E&Q plus(Meta Biomed Co., Chungju, Korea)¸¦ »ç¿ëÇÏ¿© 35/.06 gutta-percha coneÀ¸·Î ÃæÀüÇÏ¿´´Ù. ¸ðµç Ä¡¾ÆÀÇ ±Ù÷°ø ÁÖº¯ 1 mm¸¦ Á¦¿ÜÇÏ°í nail varnish¸¦ µµÆ÷ÇÏ¿´°í À½¼º ´ëÁ¶±ºÀº ±Ù÷°øÀ» Æ÷ÇÔÇÏ¿© Àüü ¸éÀ» µµÆ÷ÇÏ¿´´Ù. ¸ðµç ½ÃÆíÀ» 1% ¸ÞÆ¿·»ºí·ç ¿ë¾×¿¡ 72½Ã°£ µ¿¾È º¸°üÇÑ ´ÙÀ½ Ä¡±Ù÷À¸·ÎºÎÅÍ 1, 2, 3 mm ³ôÀÌ¿¡¼­ ¼öÆòÀ¸·Î Àý´ÜÇÏ¿´´Ù. °¢ ´Ü¸éÀ» 12.5{times}2.5¹è Çö¹Ì°æÇÏ¿¡¼­ °üÂûÇÏ°í µðÁöÅÐ Ä«¸Þ¶ó·Î ÃÔ¿µÇÏ¿´´Ù. ¿°»öÁ¦ ´©Ãâ Æò°¡¸¦ À§ÇØ aye-degree scoring systemÀ» »ç¿ëÇÏ¿´´Ù. °¢ Àý´Ü¸é¿¡¼­ÀÇ Á¡¼ö¸¦ ¸ðµÎ ÇÕÇÏ¿© ÇÑ ½ÃÆíÀÇ Á¡¼ö·Î »ç¿ëÇÏ°í Åë°èÇÐÀû ºÐ¼®À» ÇÏ¿´´Ù. ÀÌ ½ÇÇè Á¶°ÇÇÏ¿¡¼­, 3-7 mm±îÁöÀÇ heat source pluggerÀÇ Àû¿ë ±íÀÌ´Â ±Ù´ÜºÎ Æó¼â¿¡¼­ À¯ÀÇÇÑ Â÷À̸¦ ³ªÅ¸³»Áö ¾Ê¾Ò´Ù. 5-7 mmÀÇ Buchanan¡¯s protocolÀ» Æ÷ÇÔÇÑ 3-7 mm¸¦ ¸ðµÎ ÀÓ»ó Àû¿ë¿¡¼­ ¹Þ¾Æµé¿©Áú ¸¸ÇÏ´Ù°í º¸ÀδÙ.

The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with 35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at 12.5{times}2.5 fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan¡¯s protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

Å°¿öµå

Continuous wave ÃæÀü¹ý;Plugging ±íÀÌ;´©Ãâ
Continuous wave of obturation technique;dye leakage;heat source;plugging depth