Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¹Ú½º ÇüÅÂÀÇ º¹ÇÕ·¹Áø ¼öº¹½Ã ÃæÀü¹ý ¹× ¿Íµ¿º®¿¡ µû¸¥ °áÇÕ·Â Â÷ÀÌ¿¡ °üÇÑ ¿¬±¸

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2009³â 34±Ç 4È£ p.350 ~ 355
°íÀºÁÖ, ½Åµ¿ÈÆ,
¼Ò¼Ó »ó¼¼Á¤º¸
°íÀºÁÖ ( Ko Eun-Joo ) - ´Ü±¹´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç
½Åµ¿ÈÆ ( Shin Dong-Hoon ) - ´Ü±¹´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç

Abstract

º¹ÇÕ ·¹ÁøÀº ÁßÇյǴ µ¿¾È ¼öÃàÀ¸·Î ÀÎÇÑ ÀÀ·ÂÀÌ ¹ß»ýÇÏ°Ô µÇ°í ÀÌ´Â °áÇÕ·Â ½ÇÆи¦ ¾ß±âÇÑ´Ù. Ä¡Áú°úÀÇ °áÇÕ·ÂÀº Á¢Âø¸éÀÇ ¼ºÁú¿¡ ¿µÇâÀ» ¹Þ°Ô µÇ´Âµ¥ ´ëºÎºÐÀÇ ¿¬±¸µéÀº ÆíÆòÇÑ Á¢Âø¸é»ó¿¡¼­ ÀÌ·ç¾îÁ³À¸¸ç ¿Íµ¿³» ¿Íº® À§Ä¡¿¡ µû¸¥ °áÇÕ·Â Â÷ÀÌ¿¡ °üÇÑ ¿¬±¸´Â ¹Ì¹ÌÇÑ ½ÇÁ¤ÀÌ´Ù. ÀÌ¿¡ º» ¿¬±¸¿¡¼­´Â ¥°±Þ º¹ÇÕ·¹Áø ¼öº¹½Ã ´ÜÀÏ ÃæÀüÇÑ °æ¿ì¿Í ÀûÃþ ÃæÀüÇÑ °æ¿ì¿¡ À־ ¿Íµ¿ÀÇ Ä¡¼öº®°ú Ãøº®¿¡¼­ÀÇ °áÇÕ·Â Â÷À̸¦ ¾Ë¾Æº¸°íÀÚ ÇÏ¿´´Ù. ¹ß°ÅµÈ 20°³ÀÇ °ÇÀüÇÑ Á¦3 ´ë±¸Ä¡¸¦ ´ë»óÀ¸·Î 6 ¡¿ 4 ¡¿ 3 mm Å©±âÀÇ ¹Ú½º ÇüÅ·Π¿Íµ¿À» Çü¼ºÇÑ ÈÄ ·¹Áø ÃæÀü¹æ¹ý°ú ¿Íµ¿º®¿¡ µû¶ó 4°³ ±ºÀ¸·Î ºÐ·ùÇÏ¿´´Ù. ´ÜÀÏ ÃæÀüÇÏ°í Ä¡¼öº®ÀÇ °áÇÕ·ÂÀ» ÃøÁ¤ÇÑ A±º, ´ÜÀÏ ÃæÀüÇÏ°í Ãøº®ÀÇ °áÇÕ·ÂÀ» ÃøÁ¤ÇÑ B±º, ÀûÃþ ÃæÀüÇÏ°í Ä¡¼öº®ÀÇ °áÇÕ·ÂÀ» ÃøÁ¤ÇÑ C±º, ÀûÃþ ÃæÀüÇÏ°í Ãøº®ÀÇ °áÇÕ·ÂÀ» ÃøÁ¤ÇÑ D±ºÀ¸·Î ¼³Á¤ÇÏ¿´´Ù. Á¦Á¶»çÀÇ Áö½Ã¿¡ µû¶ó Clearfil SE bond? (Kuraray Corp., Osaka, Japan)·Î Ä¡¸é ó¸®ÇÑ ÈÄ Filteck Z 250? (3M/ESPE., St. Paul, USA)À» »ç¿ëÇÏ¿© ¿Íµ¿À» ÃæÀüÇÏ¿´´Ù. ÀûÃþ ÃæÀü±ºÀÇ °æ¿ì 1.5 mm¾¿ µÎ ¹ø¿¡ ³ª´©¾î ÃæÀüÇÏ°í °¢°¢ 40Ãʾ¿ ÁßÇÕÇÏ¿´´Ù. 37¡ÉÀÇ Áõ·ù¼ö¿¡¼­ 24½Ã°£ º¸°ü ÈÄ ±³ÇÕ¸éÂÊ ¹ý¶ûÁúÀ» Á¦°ÅÇÏ°í ¼öº¹¹°ÀÇ ±Ù¿ø½É ÆøÀÇ Àý ¹ÝµÇ´Â ÁöÁ¡¿¡¼­ Çù¼³ ¹æÇâÀ¸·Î Ä¡¾Æ¸¦ À߶ú´Ù. ÁÖ¼öÇÏ¿¡ °í¼Ó diamond saw¸¦ »ç¿ëÇÏ¿© °¢ Ä¡¾ÆÀÇ Á¢Âø¸é¿¡ ¼öÁ÷À¸·Î 1 ¡¿ 1 ¡¿ 7 mmÀÇ ¸·´ë ÇüÅÂÀÇ ½ÃÆíÀ» ¸¸µé¾úÀ¸¸ç ¸¸´É½ÃÇè±â¿¡ ºÎÂøÇÏ°í 1 mm/minÀÇ ¼Óµµ·Î ¹Ì¼¼ÀÎÀå °áÇÕ°­µµ¸¦ ÃøÁ¤ÇÏ¿´´Ù. 2-way ANOVA test¿Í t-test ¸¦ ÀÌ¿ëÇÏ¿© 95% À¯ÀǼöÁØÀ¸·Î Åë°è ºÐ¼®ÇÑ °á°ú´Â ´ÙÀ½°ú °°´Ù. 1. ÃæÀü ¹æ¹ýÀÇ °æ¿ì, ÀûÃþ ÃæÀü±ºÀÌ ´ÜÀÏ ÃæÀü±ºº¸´Ù ³ôÀº Æò±Õ°ªÀ» º¸¿´À¸³ª Åë°èÀû À¯ÀǼºÀº ¾ø¾ú´Ù. 2. ¿Íµ¿º®¿¡ µû¸¥ °áÇÕ·Â Â÷ÀÌÀÇ °æ¿ì, Ä¡¼öº® ±ºÀÌ Ãøº® ±ºº¸´Ù °áÇÕ·ÂÀÌ Å« °ÍÀ¸·Î ³ªÅ¸³µÀ¸³ª À¯ÀǼºÀº ¾ø¾ú´Ù. º» ¿¬±¸ °á°ú¸¸À» Åä´ë·Î º¼ ¶§, ÃæÀü ¹æ¹ý°ú ¿Íµ¿º®ÀÇ µÎ °¡Áö ¿ä¼Ò°¡ Ä¡Áú°úÀÇ °áÇշ¿¡ ¹ÌÄ¡´Â ¿µÇâÀÌ Å©Áö ¾Ê¾Ò´Ù.

Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ¡¿ 4 ¡¿ 3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling- pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek Z250? (3M/ESPE., USA) and Clearfill SE bond? (Kuraray, Japan). After 24 hour-storage in 37¡É water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ¡¿ 1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.

Å°¿öµå

°áÇÕ·Â;¿Íµ¿º®;ÃæÀü ¹æ¹ý;¹Ì¼¼ÀÎÀå °áÇÕ·Â Å×½ºÆ®
Bond strength;Bonding surface;Cavity wall;Filling technique;Microtensile test

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI