Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

30% °ú»êÈ­¼ö¼Ò¸¦ ÇÔÀ¯ÇÑ Àü¹®°¡ ¹Ì¹éÁ¦ÀÇ È¿¿ë¼º Æò°¡

A CLINICAL EVALUATION OF EFFICACY OF AN OFFICE BLEACHING GEL CONTAINING 30% HYDROGEN PEROXIDE

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2010³â 35±Ç 1È£ p.40 ~ 50
±è½Å¿µ, ¹ÚÀç¾ï, ±èâÇö, ¾ç¼ºÀº,
¼Ò¼Ó »ó¼¼Á¤º¸
±è½Å¿µ ( Kim Sin-Young ) - °¡Å縯´ëÇб³ ¼­¿ï¼º¸ðº´¿ø Ä¡°úº¸Á¸°ú
¹ÚÀç¾ï ( Park Je-Uk ) - °¡Å縯´ëÇб³ ¼­¿ï¼º¸ðº´¿ø ±¸°­¾Ç¾È¸é¿Ü°ú
±èâÇö ( Kim Chang-Hyen ) - °¡Å縯´ëÇб³ ¼­¿ï¼º¸ðº´¿ø ±¸°­¾Ç¾È¸é¿Ü°ú
¾ç¼ºÀº ( Yang Sung-Eun ) - °¡Å縯´ëÇб³ ¼­¿ï¼º¸ðº´¿ø Ä¡°úº¸Á¸°ú

Abstract

30% °ú»êÈ­¼ö¼Ò¸¦ ÇÔÀ¯ÇÑ Àü¹®°¡ ¹Ì¹éÁ¦ÀÎ ·¹¸ÞÈ­ÀÌÆ®(Remewhite, Remedent Inc., Deurle, Belgium)¸¦ ½ÃÇ豺 ÇÇÇèÀÚ 31¸í, ½ÃÇè¿ë ¹Ì¹éÁ¦¿¡¼­ °ú»êÈ­¼ö¼Ò¸¦ Á¦¿ÜÇÑ µ¿ÀÏÇÑ Á¦À縦 ´ëÁ¶¾àÀ¸·Î ´ëÁ¶±º ÇÇÇèÀÚ 31¸í¿¡°Ô 1ÀÏ 3ȸ¾¿, 2Â÷·Ê¿¡ °ÉÃÄ ¼­ ½ÃÇàÇÏ¿´´Ù. ¹Ì¹éÀÇ ÀÓ»óÀû È¿¿ë¼ºÀº Colorimeter, Vitapan classical shade guide¸¦ ÀÌ¿ëÇÏ¿© Àüü »öº¯È­·®(¥ÄE*)À» ÃøÁ¤ÇÏ¿´´Ù. 14ÁÖ ÈÄ¿Í 26ÁÖ ÈÄÀÇ »öº¯È­·®À» ÃøÁ¤ÇÏ¿© ±º °£ »öº¯È­·®À» ºñ±³ÇÏ¿´°í, °¢ ±º ³»¿¡¼­ÀÇ »öº¯È­·®µµ ºñ±³ÇÏ¿© ´ÙÀ½°ú °°Àº °á·ÐÀ» ¾ò¾ú´Ù. 1. Colorimeter¸¦ ÀÌ¿ëÇÑ Æò°¡½Ã¿¡ ½ÃÇ豺¿¡¼­ Àüü »öº¯È­·®(¥ÄE*)Àº ´ëÁ¶±º¿¡ ºñÇØ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷À̸¦ º¸¿´°í, Vitapan classical shade guide¸¦ ÀÌ¿ëÇÑ Æò°¡½Ã¿¡´Â Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷À̸¦ ³ªÅ¸³»Áö ¾Ê¾Ò´Ù(p < 0.05). 2. ½Ã°£ÀÌ Áö³²¿¡ µû¶ó »ö º¹¿ø Çö»óÀÌ ³ªÅ¸³²¿¡µµ ºÒ±¸ÇÏ°í ¹Ì¹é ½ÃÇà 14ÁÖ ÈÄ¿Í 26ÁÖ ÈÄ¿¡µµ ¹Ì¹éÀÇ È¿°ú°¡ À¯ÁöµÈ´Ù°í ÇÒ¼ö ÀÖ´Ù. 3. Colorimeter¸¦ ÀÌ¿ëÇÑ Æò°¡½Ã¿¡ Vitapan classical shade guide¸¦ ÀÌ¿ëÇÑ Æò°¡½Ãº¸´Ù ÀÛÀº »öº¯È­·®À» ´õ Á¤È®ÇÏ°Ô ÃøÁ¤ÇÒ ¼ö ÀÖ´Ù.

This study evaluated the efficacy of an office bleaching gel (RemeWhite, Remedent Inc., Deurle, Belgium) containing 30% hydrogen peroxide. 31 volunteers were recieved office bleaching with the RemeWhite for 3 times at one visit, total 2 visits. As control group, the same gel in which hydrogen peroxide was not included was applied to 31 volunteers with the same protocol. The shade change (¥ÄE*, color difference) of 12 anterior teeth was measured using Colorimerter and Vitapan classical shade guide. The shade change of overall teeth in the experimental group was significantly greater than that in the control group which was measured using Colorimeter. There was also a significant difference between baseline and 14 weeks or 26 weeks though color rebounding phenomenon occurred as time went by. Small shade change difference can be measured accurately using Colorimeter than using Vitapan classical shade guide. [J Kor Acad Cons Dent 35(1):40-50, 2010]

Å°¿öµå

Àü¹®°¡ ¹Ì¹éÁ¦;È¿¿ë¼º;°ú»êÈ­¼ö¼Ò;ÀÓ»ó ¿¬±¸
Office bleaching gel;Efficacy;Hydrogen peroxide;Clinical study -Received 2010.1.5.; revised 2010.1.8.; accepted 2010.1.14.-

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI