Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

»ó¾ÆÁú Á¢ÂøÁ¦ÀÇ ¿ë¸Å Áõ¹ßÀÌ Á¢Âø È¿À²¿¡ ¹ÌÄ¡´Â ¿µÇâ

The effect of solvent evaporation of dentin adhesive on bonding efficacy

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2010³â 35±Ç 5È£ p.321 ~ 334
Á¶¹Î¿ì, ±èÁö¿¬, ±è´ö¼ö, ÃÖ°æ±Ô,
¼Ò¼Ó »ó¼¼Á¤º¸
Á¶¹Î¿ì ( Cho Min-Woo ) - °æÈñ´ëÇб³ ´ëÇпø Ä¡ÀÇÇаú Ä¡°úº¸Á¸Çб³½Ç
±èÁö¿¬ ( Kim Ji-Yeon ) - °æÈñ´ëÇб³ ´ëÇпø Ä¡ÀÇÇаú Ä¡°úº¸Á¸Çб³½Ç
±è´ö¼ö ( Kim Duck-Su ) - °æÈñ´ëÇб³ ´ëÇпø Ä¡ÀÇÇаú Ä¡°úº¸Á¸Çб³½Ç
ÃÖ°æ±Ô ( Choi Kyoung-Kyu ) - °æÈñ´ëÇб³ ´ëÇпø Ä¡ÀÇÇаú Ä¡°úº¸Á¸Çб³½Ç

Abstract

¿¬±¸¸ñÀû: º» ¿¬±¸´Â »ó¾ÆÁú Á¢ÂøÁ¦ÀÇ ÀÜ·ù ¿ë¸Å°¡ Á¢Âø È¿À²¿¡ ¹ÌÄ¡´Â ¿µÇâÀ» Æò°¡ÇÏ°íÀÚ ÇÏ¿´´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: º» ¿¬±¸¿¡¼­´Â 5¼¼´ë 2´Ü°è »êºÎ½ÄÇü Á¢ÂøÁ¦¿Í 7¼¼´ë ´ÜÀÏ°úÁ¤ ÀÚ°¡ºÎ½ÄÇü Á¢ÂøÁ¦¸¦ »ç¿ëÇÏ¿´´Ù. »ó¾ÆÁú Á¢ÂøÁ¦ÀÇ Áõ¹ß·ü°ú Àüȯ·ü, Àû¿ë ÈÄ ¿ë¸ÅÀÇ °ø±â°ÇÁ¶ ¹æ¹ý¿¡ µû¸¥ ¹Ì¼¼ÀÎÀå°áÇÕ°­µµ¸¦ ÃøÁ¤ÇÏ¿´À¸¸ç Á¢Âø °è¸éÀ» FE-SEMÀ» ÀÌ¿ëÇÏ¿© °üÂûÇÏ¿´´Ù.

°á°ú: 1. ½Ã°£¿¡ µû¶ó Á¢ÂøÁ¦ÀÇ Áõ¹ß·üÀº Áõ°¡Çϳª Á¢ÂøÁ¦ÀÇ Á¾·ù¿¡ µû¶ó Áõ°¡ ¾ç»óÀÌ ¼­·Î ´Þ¶ú´Ù. 2. ´ëºÎºÐ Àüȯ·üÀº Áõ¹ß·ü¿¡ ºñ·ÊÇÏ´Â °æÇâÀ» ³ªÅ¸³»¾ú´Ù. 3. °ø±â°ÇÁ¶ ¹æ¹ý¿¡ µû¶ó °áÇÕ°­µµ´Â ´ëºÎºÐ under±º, control±º, over±º ¼øÀ¸·Î Áõ°¡ÇÏ´Â ¾ç»óÀ» ³ªÅ¸³»¾ú´Ù. 4. FE-SEM¿¡¼­ ¾Æ¼¼ÅæÀ» ¿ë¸Å·Î »ç¿ëÇÏ´Â Á¢ÂøÁ¦´Â °ø±â°ÇÁ¶ ¹æ¹ý¿¡ µû¶ó dropletÀ̳ª gapÀÌ °üÂûµÇ¾ú´Ù.

°á·Ð: »ó¾ÆÁú Á¢ÂøÁ¦ÀÇ ÀÜ·ù ¿ë¸Å´Â Á¢Âø È¿À²¿¡ ºÎÁ¤ÀûÀÎ ¿µÇâÀ» ¹ÌÄ¡±â ¶§¹®¿¡, »ó¾ÆÁú Á¢ÂøÁ¦ÀÇ ¼±Åðú »ç¿ë ½Ã ¿ë¸ÅÀÇ Á¾·ù¿Í Ư¡¿¡ ´ëÇÑ ÀûÀýÇÑ ÀÌÇØ°¡ ÇÊ¿äÇÒ °ÍÀÌ´Ù.

Objectives: The purpose of this study is to evaluate bonding efficacy by means of measuring the effect of remained solvent on Degree of conversion(DC) and and FE-SEM examination.

Materials and Methods: Two 2-step total etching adhesives and two single-step self etching adhesives were used in this study. First, volume weight loss of 4 dentin adhesives were measured using weighting machine in process of time in normal conditions and calculate degree of evaporation (DE). Reaction/reference intensity ratio were measured using micro-Raman spectroscopy and calculate DC according to DE. Then 2 experimental groups were prepared according to air-drying methods (under, over) and control group was prepared to manufacturer¡¯s instruction. Total 12 groups were evaluated by means of micro tensile bond strength and FE-SEM examination.

Results: Degree of evaporation (DE) was increased as time elapsed but different features were observed according to the kind of solvents. Acetone based adhesive showed higher DE than ethanol and butanol based adhesive. Degree of conversion (DC) was increased according to DE except for bond. In evaluation, bond strength was increased by additional air-drying. Large gaps and droplets were observed in acetone based adhesives by FE-SEM pictures.

Conclusions: Additional air-drying is recommended for single-step self etching adhesive but careful consideration is required for 2-step total etching adhesive because of oxygen inhibition layer. Evaporation method is carefully chose and applied according to the solvent type.

Å°¿öµå

¶ó¸¸ºÐ±¤±â; »ó¾ÆÁú Á¢ÂøÁ¦; ÀÜ·ù ¿ë¸Å; Àüȯ·ü; Á¢ÂøÈ¿À²; Áõ¹ß·ü
Bonding efficacy; Degree of conversion; Degree of evaporation; Dentin adhesive; Raman spectroscopy; Residual solvent

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI