Orthograde MTA ÃæÀüÀÇ ½ÇÆÐ
Failure of orthograde MTA filling: MTA wash-out?
±èÀ¯¶õ, ÀÌÂù¿µ, ±èÀǼº, Á¤ÀÏ¿µ,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÀ¯¶õ ( Kim Yu-Ran ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç
ÀÌÂù¿µ ( Lee Chan-Young ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç
±èÀǼº ( Kim Eui-Seong ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç
Á¤ÀÏ¿µ ( Jung Il-Young ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Á¸Çб³½Ç
KMID : 0362320110360060510
Abstract
Mineral trioxide aggregate (MTA), which was originally developed for repair of root perforations, is a biocompatible material with numerous clinical applications in endodontics. MTA must be allowed to set in the presence of moisture to optimize the material¡¯s physical and chemical properties. In the clinic, occasionally unset MTA has been detected after application of MTA on the tooth, and the reason has been unclear.
This case report presents MTA washed-out for several years after placement at the root apex as an apical plug, and discusses the reason and things to consider in clinics.
Å°¿öµå
MTA; Orthograde MTA filling; Setting
¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸
µîÀçÀú³Î Á¤º¸