Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Power density of various light curing units through resin inlays with modified layer thickness

´ëÇÑÄ¡°úº¸Á¸ÇÐȸÁö 2012³â 37±Ç 3È£ p.130 ~ 135
È«¼º¿Á, Oh Yong-Hui, ¹ÎÁ¤¹ü, ±èÁø¿ì, À̺ó³ª, ȲÀ±Âù, ȲÀγ², ¿À¿ø¸¸, ÀåÈÆ»ó,
¼Ò¼Ó »ó¼¼Á¤º¸
È«¼º¿Á ( Hong Sung-Ok ) - Wonkwang University College of Dentistry and Dental Research Institute, Iksan Department of Conservative Dentistry
 ( Oh Yong-Hui ) - Daejin University Department of Industrial and Management Engineering
¹ÎÁ¤¹ü ( Min Jeong-Bum ) - Chosun University School of Dentistry Department of Conservative Dentistry
±èÁø¿ì ( Kim Jin-Woo ) - Gangneung-Wonju National University College of Dentistry Department of Conservative Dentistry
À̺󳪠( Lee Bin-Na ) - Chonnam National University School of Dentistry and Dental Science Research Institute Department of Conservative Dentistry
ȲÀ±Âù ( Hwang Yun-Chan ) - Chonnam National University School of Dentistry and Dental Science Research Institute Department of Conservative Dentistry
ȲÀγ² ( Hwang In-Nam ) - Chonnam National University School of Dentistry and Dental Science Research Institute Department of Conservative Dentistry
¿À¿ø¸¸ ( Oh Won-Mann ) - Chonnam National University School of Dentistry and Dental Science Research Institute Department of Conservative Dentistry
ÀåÈÆ»ó ( Chang Hoon-Sang ) - Chonnam National University School of Dentistry and Dental Science Research Institute Department of Conservative Dentistry

Abstract


Objectives: The purpose of this study was to enhance curing light penetration through resin inlays by modifying the thicknesses of the dentin, enamel, and translucent layers.

Materials and Methods: To investigate the layer dominantly affecting the power density of light curing units, resin wafers of each layer with 0.5 mm thickness were prepared and power density through resin wafers was measured with a dental radiometer (Cure Rite, Kerr). The dentin layer, which had the dominant effect on power density reduction, was decreased in thickness from 0.5 to 0.1 mm while thickness of the enamel layer was kept unchanged at 0.5 mm and thickness of the translucent layer was increased from 0.5 to 0.9 mm and vice versa, in order to maintain the total thickness of 1.5 mm of the resin inlay. Power density of various light curing units through resin inlays was measured.

Results: Power density measured through 0.5 mm resin wafers decreased more significantly with the dentin layer than with the enamel and translucent layers (p < 0.05). Power density through 1.5 mm resin inlays increased when the dentin layer thickness was reduced and the enamel or translucent layer thickness was increased. The highest power density was recorded with dentin layer thickness of 0.1 mm and increased translucent layer thickness in all light curing units.

Conclusions: To enhance the power density through resin inlays, reducing the dentin layer thickness and increasing the translucent layer thickness would be recommendable when fabricating resin inlays.

Å°¿öµå

Dental radiometer; Layer thickness; Power density; Resin inlay

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI