Cemented type implant¿¡¼­ Áö´ëÄ¡ÀÇ Ç¥¸éÁ¶µµ¿Í cementÀÇ Á¾·ù°¡ Retrievability¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ °üÇÑ ¿¬±¸

THE RETRIEVABILITY OF CEMENTATION TYPE IMPLANT ABUTMENT BY SURFACE TREATMENTS AND TYPES OF CEMENTS.

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 1999³â 37±Ç 5È£ p.651 ~ 657
ÀÌÀçºÀ,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌÀçºÀ ( Lee Jai-Bong ) - ¾ÆÁÖ´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç

Abstract


This study was performed to investigate the retrievability of the cementation type implant abutments. The cements used in this study were Cavitec, Tembond and Zine Phosphate Cement. The types of surface conditioning were no treatment, 50 microne sandblasting, 250 microne sandblasting, fine diamond finishing point and coarse diamond point. The retention of cast crown was measured with Instron University Testing Machine(Instron Engineering Co., U.S.A.) The results were as follows: 1. The Maximium retention was obtained by the group of Z.P.C. cementation and Coarse diamond point surface conditioning. 2. Z.P.C. shows maximum retention, and reduced in orders Tembond, Cavitec, No cement. 3. The value of retention of surface condition was highest in coarse diamond point, lowest in no tretment. 4. The similar results were obtained between fine diamond point and 50 microne sandblasting, coarse diamond point and 250 microne sandblasting. 5. The were no direct corelation between mechanical retetnion and cementation retention.