Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¼¶À¯°­È­Çü º¹ÇÕ·¹ÁøÀüÀå°üÀÇ º¯¿¬ÀûÇÕµµ ¹× º¯¿¬´©Ãâ¿¡ °üÇÑ ¿¬±¸

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEPENDING UPON LUTING CEMENTS

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2000³â 38±Ç 5È£ p.618 ~ 630
±è¼±Á¾, ½Å»ó¿Ï, ÇÑÁß¼®, ¼­±Ô¿ø,
¼Ò¼Ó »ó¼¼Á¤º¸
±è¼±Á¾ ( Kim Sun-Jong ) - °í·Á´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç
½Å»ó¿Ï ( Shin Sang-Wan ) - °í·Á´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç
ÇÑÁß¼® ( Han Jung-Suk ) - ÀÌÈ­¿©ÀÚ´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç
¼­±Ô¿ø ( Suh Kyu-Won ) - °í·Á´ëÇб³ ÀÇ°ú´ëÇÐ Ä¡°úÇб³½Ç

Abstract


As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation, conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiberreinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements.(Bistite II., Super-bond., Variolink II.), Zinc phosphate and Glass- Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of 5degrees C and 55degrees C in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II(46.78micrometer), Variolink II(56.25micrometer), Super-Bond(56.78 micrometer), Glass-Ionomer(99.21micrometer), Zinc Phosphate(109.49micrometer) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate. 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

Å°¿öµå

Marginal fitness;Marginal leakage;Fiber reinforced composite(FRC);Ceromer;Thermocycling

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

   

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed