Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

CAD/CAMÀ¸·Î Á¦ÀÛÇÑ ÄÚ´©½º³»°üÀÇ º¯¿¬ÀûÇÕ

Marginal Adaptation Of The Conical Inner Crown Fabricated With Cad/cam

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2002³â 40±Ç 1È£ p.30 ~ 41
±èÀμ·, °­µ¿¿Ï,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÀμ· ( Kim In-Sup ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶Çб³½Ç
°­µ¿¿Ï ( Kang Dong-Wan ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ º¸Ã¶Çб³½Ç

Abstract


This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM.The informations on abutment teeth were transferred to a computer with a micro contact digitizer,which had a 50mum accuracy on the master die.A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy.Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial,distal,buccal,and lingual surfaces)of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1.The mean marginal gap between the conical inner crown and abutment tooth was 83.2 +/-43mum,28.9%of the specimen showed marginal gap over 100 m. 2.The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (p<0.05).

Å°¿öµå

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

   

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed