Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

±¸Ä¡¿ë µµÀç¼ÒºÎ±Ý°ü°ú ÀüºÎµµÀç°ü¿¡ ÆÄÀýÀ» ÀÏÀ¸Å°´Â Çѱ¹À½½Ä¿¡ °üÇÑ ¿¬±¸

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2009³â 47±Ç 2È£ p.156 ~ 163
±èÁ¤È£, ÀÌÀçºÀ,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÁ¤È£ ( Kim Jeong-Ho ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
ÀÌÀçºÀ ( Lee Jai-Bong ) - ¼­¿ï´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¿¬±¸¸ñÀû: 4Á¾ ±¸Ä¡¿ëµµÀç°ü (Full-porcelain-occlusal-surfaced PFG, Half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon)°ú ¼±º°µÈ Çѱ¹À½½ÄÀÇ fracture load¿Í dynamic cyclic load¸¦ ÃøÁ¤ÇÏ¿© ±¸Ä¡¿ë µµÀç°ü¿¡ ÆÄÀýÀ» ÀÏÀ¸Å³ °¡´É¼ºÀÌ ÀÖ´Â Çѱ¹À½½ÄÀ» ¼±º°Çϴµ¥ ÀÖ´Ù.

¿¬±¸Àç·á ¹× ¹æ¹ý: 4Á¾ÀÇ °¢ porcelain º¸Ã¶¹° system ´ç 15°³ÀÇ Ãà´ëĪÀ» ÀÌ·ç´Â crownÀ» Á¦ÀÛÇß´Ù. À̶§ occlusal reductionÀº 1.5 - 2.0 mm·Î Çß´Ù (Á߽ɺΠ1.5mm, ±³µÎºÎ 2.0 mm). °¢ 15°³ÀÇ ½ÃÆíÀÇ ±³ÇÕ¸é Á߾Ӻο¡ Á÷°æ 5 mmÀÇ stainless steel ballÀ» À§Ä¡½ÃŲ ÈÄ Instron 4465 universal testing machine (Instron, Norwood, MA USA)À» ÀÌ¿ëÇÏ¿© 5mm/minÀÇ crosshead speed·Î ¼öÁ÷ ºÎÇϸ¦ ÁÖ¾î ÆÄÀýÀ» ÀÏÀ¸Å°´Â ÃÖ´ë ºÎÇÏ (N)¸¦ ±â·ÏÇß´Ù. ÀÌÈÄ, Çѱ¹À½½Ä Áß »îÀº °Ô, ´ß (»ÀÆ÷ÇÔ), ¼Ò°¥ºñ(»ÀÆ÷ÇÔ), ¸¶¸¥ ¿À¡¾î, °Ç¸êÄ¡, »çÅÁ, È£µÎ²®ÁúÀ» Ç¥º»À¸·Î ¼³Á¤ÇÏ°í À̵éÀ» ÆÄÀý½ÃÅ°´Â ÃÖ´ë ºÎÇÏ (N)¸¦ universal testing machine (Instron 4465) ¿¡¼­ ÃøÁ¤ÇÏ¿© ±â·ÏÇß´Ù. °¢ Ç׸ñ´ç 15¹øÀ» ÃøÁ¤Çß´Ù. À½½Ä¹°À» ÆÄÀý½Ãų ¶§ ÇÊ¿äÇÑ ÃÖ´ëºÎÇÏ¿Í °¢ º¸Ã¶¹°ÀÇ ÆÄÀýÀúÇ×À» ºñ±³ÇÏ¿© Çѱ¹ÀÇ ½Ä½À°ü°ú µµÀ縦 ÀÌ¿ëÇÑ º¸Ã¶¹° ÆÄÀýÀÇ »ó°ü°ü°è¸¦ Á¶»çÇÏ¿´´Ù. fracture loads´Â analysis of variance ¿Í Post Hoc tests¸¦ ÀÌ¿ëÇؼ­ ºÐ¼®ÇÏ¿´´Ù (¥á= 0.05). Â÷ÈÄ¿¡ À§¿¡¼­ ¾òÀº °á°ú¸¦ ¹ÙÅÁÀ¸·Î Hydraulic Dynamic Fatigue Testing Machine (858 Bionix II, MTS systems, Eden Prairie, MN USA)¸¦ ÀÌ¿ëÇÏ¿© 4Á¾ÀÇ °¢ porcelain º¸Ã¶¹° system´ç 5°³ÀÇ crown¿¡ 14Hz Cyclic Load¸¦ °¡ÇÏ¿© crown¿¡ ÆÄÀýÀ» ÀÏÀ¸Å°´Â masticatory cycle¼ö¸¦ ¾Ë¾Æ º¸¾Ò´Ù. Load ¼öÄ¡´Â 41.0 N (°Ç¸êÄ¡ ÆÄÀý°­µµ), 169.0 N (¸¶¸¥¿À¡¾î ÆÄÀý°­µµ), 382.9N (´ß»À ÆÄÀý°­µµ), 2224.8 N (»çÅÁ ÆÄÀý°­µµ)·Î ¼³Á¤ÇÏ¿´´Ù.

°á °ú: 95% confidence intervals for mean fracture load´Â 2599.3 - 2809.1 N (¿ÏÀüµµÀç±³ÇÕ¸é PFG), 3689.4 - 3819.9 N (¹ÝµµÀç±³ÇÕ¸é PFG), 1501.2 - 1867.9 N (Ice Zirkon), 803.2 - 1188.5 N (Empress 2)·Î ³ª¿Ô°í 95% confidence intervals for dynamic cyclic load on fracture´Â instron »ó¿¡¼­ µµÀ纸ö¹°¿¡ ÆÄÀýÀ» ÀÏÀ¸Å°Áö ¾ÊÀº loadÀÎ 2224.8 N (»çÅÁ ÆÄÀý°­µµ)¿Í 382.9 N (´ß»À ÆÄÀý°­µµ)·Î ½ÇÇèÇßÀ» ¶§, 2224.8 N¿¡¼­ 4796.8 - 9321.2 cycles (¿ÏÀüµµÀç±³ÇÕ¸é PFG), 2224.8 N¿¡¼­ 881705.1 -1143565.7 cycles (¹ÝµµÀç±³ÇÕ¸é PFG), 382.9 N¿¡¼­ 979993.0 - 1145773.4 cycles (Ice Zirkon), 382.9 N¿¡¼­ 564.1 - 954.7 cycles (Empress 2)·Î ³ª¿Ô´Ù.

°á ·Ð: Åë°èÇÐÀûÀ¸·Î À¯ÀÇÇÒ ¸¸ÇÑ Â÷ÀÌ°¡ ±×·ìµé °£ fracture load¿¡¼­ ³ªÅ¸³µ´Ù. Çѱ¹À½½Ä¹° Áß ¼Ò°¥ºñ (»ÀÆ÷ÇÔ)¿Í »çÅÁ (ÀڵθÀĵµð)Àº ±¸Ä¡¿ë µµÀ纸ö¹°À» ÆÄÀý½Ãų °¡´É¼ºÀÌ ÀÖ´Â À½½Ä¹°·Î ¹àÇôÁ³´Ù. ´ÜÀϼöÁ÷ºÎÇÏ¿¡¼­´Â ÆÄÀýÀÌ »ý±âÁö ¾Ê´Â °æ¿ì¶ó ÇÒÁö¶óµµ dynamic cyclic load¸¦ ÁÙ °æ¿ì ÀÏÁ¤ ÁÖ±â ÈÄ¿¡ ÆÄÀýÀÌ »ý±â´Â °á°ú¸¦ ¾òÀ» ¼ö ÀÖ¾ú´Ù.

Statement of Problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food.

Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods.

Material and Methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load (N) was recorded. Afterwards, selected Korean foods
specimens (boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests.

Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load (14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8 - 9321.2 cycles under 2224.8 N (round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1 - 1143565.7 cycles under 2224.8 N (round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0 - 1145773.4 cycles under 382.9 N (boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1 - 954.7 cycles under 382.9 N (boiled chicken with bone). no fracture under smaller loads.

Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown (full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy (2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy (2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone (382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone (382.9 N).

Å°¿öµå

ÆÄÀýÀúÇ×;µµÀç¼ÒºÎ±Ý°ü;ÀüºÎµµÀç°ü;ÁÖ±âÀû ±³ÇÕ¾Ð
fracture resistance;PFG;all ceramic crown;cyclic load;masticatory load

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed