º¹ÇÕ·¹ÁøÀ¸·Î ¼öº¹ÇÑ 5±Þ ¿Íµ¿ÀÇ ¹Ì¼¼´©Ãâ¿¡ ´ëÇÑ 3Á¾ÀÇ ·¹Áø Ç¥¸é Àü»öÁ¦ÀÇ È¿°ú

The effect of three surface sealants on microleakage of class V composite resin restorations

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2009³â 47±Ç 2È£ p.182 ~ 190
ÀÌ¿øö, ·ùÀçÁØ,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌ¿øö ( Lee Won-Cheol ) - °í·Á´ëÇб³ ÀÓ»óÄ¡ÀÇÇдëÇпø ½É¹Ì¼öº¹Çаú
·ùÀçÁØ ( Ryu Jae-Jun ) - °í·Á´ëÇб³ ÀÓ»óÄ¡ÀÇÇдëÇпø

Abstract

¿¬±¸¸ñÀû: º» ¿¬±¸ÀÇ ¸ñÀûÀº º¹ÇÕ ·¹Áø (Z250)À¸·Î ¼öº¹ÇÑ 5±Þ ¿Íµ¿¿¡¼­ º¯¿¬ºÎ ¹Ì¼¼´©Ãâ¿¡ ´ëÇÑ 3Á¾ÀÇ ·¹Áø Ç¥¸é Àü»öÁ¦ (Fortify, Permaseal, Biscover LV)ÀÇ È¿°ú¸¦ Æò°¡ÇÏ´Â °ÍÀÌ´Ù.

¿¬±¸Àç·á ¹× ¹æ¹ý: 3°³¿ù À̳»¿¡ ¹ß°ÅµÈ °ÇÀüÇÑ 40°³ÀÇ ¼Ò±¸Ä¡¿Í ´ë±¸Ä¡¿¡ ¹é¾Ç - ¹ý¶û °æ°è¸¦ Áß½ÉÀ¸·Î ±³ÇÕÃø º¯¿¬Àº ¹ý¶ûÁú¿¡, Ä¡ÀºÃø º¯¿¬Àº ¹é¾ÇÁú¿¡ À§Ä¡Çϵµ·Ï 5±Þ ¿Íµ¿À» Çù¸é°ú ¼³¸é¿¡ °¢°¢ Çü¼ºÇÏ¿´´Ù. Clearfil SE bond¿Í º¹ÇÕ ·¹ÁøÀ¸·Î ÃæÀüÇÑ Ä¡¾Æ¸¦ ¹«ÀÛÀ§·Î 4°³ÀÇ ±ºÀ¸·Î ºÐ·ùÇÑ ÈÄ ´ëÁ¶±ºÀ» Á¦¿ÜÇÑ ½ÇÇ豺Àº °¢°¢ 20°³ÀÇ ¿Íµ¿¿¡ ·¹Áø Ç¥¸é Àü»öÁ¦ 3°¡Áö Á¦Ç°À» °¢°¢ Àû¿ëÇÏ°í 24½Ã°£µ¿¾È »ý¸®½Ä¿°¼ö¿¡ º¸°üÇÏ¿´´Ù. º¸°üÇÑ ½ÃÆíÀ» ¿­¼øȯ½ÃŲ ÈÄ 24½Ã°£ µ¿¾È 2% methylene blue ¿°»ö ¿ë¾×¿¡ ´ã°¡ µÎ¾ú´Ù°¡ Åõ¸í ·¹Áø¿¡ ¸Å¸ôÇÏ¿´´Ù. ¸Å¸ôÇÑ ½ÃÆíÀ» Çù¼³¸éÀÇ ÃæÀü¹° Áß¾ÓÀ» Áö³ªµµ·Ï Àý´ÜÇÑ ÈÄ Çö¹Ì°æÀ» »ç¿ëÇÏ¿© ±³ÇÕ¸éÃø°ú Ä¡ÀºÃø º¯¿¬ºÎÀÇ ¿°»ö ¿ë¾×ÀÇ Ä§Åõµµ¸¦ °üÂûÇÔÀ¸·Î½á ¹Ì¼¼´©Ãâ ¿©ºÎ¿Í Á¤µµ¸¦ ºÐ¼®ÇÏ¿´´Ù.

°á °ú: º¹ÇÕ·¹ÁøÀ¸·Î¸¸ ¼öº¹ÇÑ ´ëÁ¶±ºÀº ½ÇÇ豺¿¡ ºñÇØ ±³ÇÕ¸éÃø°ú Ä¡ÀºÃø¿¡¼­ ¹Ì¼¼´©ÃâÀÌ ÄÇÀ¸¸ç Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ÀÖ¾ú´Ù (P < 0.05). ·¹Áø Ç¥¸é Àü»öÁ¦¸¦ Àû¿ëÇÑ ½ÇÇ豺µé »çÀÌ¿¡´Â ±³ÇÕ¸éÃø°ú Ä¡ÀºÃø ¸ðµÎ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾ú´Ù (P > 0.05). °¢ ±ºÀÇ ±³ÇÕ¸éÃø°ú Ä¡ÀºÃøÀÇ º¯¿¬ ¹Ì¼¼´©ÃâÀ» ºñ±³½Ã Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾ú´Ù. Fortify´Â ´ëÁ¶±º°ú ºñ±³½Ã Ä¡ÀºÃø¿¡¼­´Â Åë°èÀûÀ¸·Î À¯ÀÇÇÑ ¹Ì¼¼´©Ãâ °¨¼Ò È¿°ú°¡ ¾ø¾ú´Ù.

°á ·Ð: º¹ÇÕ·¹ÁøÀ¸·Î ÃæÀüÇÑ 5±Þ ¿Íµ¿ º¯¿¬¿¡ ·¹Áø Ç¥¸é Àü»öÁ¦¸¦ Àû¿ëÇÑ °æ¿ì ±³ÇÕ¸éÃø°ú Ä¡ÀºÃø º¯¿¬¿¡¼­ ¹Ì¼¼´©Ãâ °¨¼Ò È¿°ú°¡ ÀÖ¾ú´Ù. ±×·¯³ª Ä¡ÀºÃø º¯¿¬Àº ·¹Áø Ç¥¸é Àü»öÁ¦ÀÇ Àû¿ë ÈÄ¿¡µµ ¹Ì¼¼´©ÃâÀ» º¸À̹ǷΠ°¢º°È÷ ÁÖÀǸ¦ ¿äÇØ¾ß ÇÒ °ÍÀ¸·Î »ç·áµÈ´Ù.

Statement of Problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration.

Purpose: The aim of this study was to assess the effectiveness of three different surface sealant (Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250).
Material and Methods: Forty noncarious human premolars and molars extracted within a three-month period
were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing
procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal
and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test(¥á=0.05).

Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group (P < .05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin (P > .05).

Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

Å°¿öµå

¹Ì¼¼´©Ãâ;Ç¥¸é Àü»öÁ¦;5±Þ¿Íµ¿;fortify;permaseal; Biscover LV
microleakage;surface sealant;class V;fortify;permaseal;biscover LV