Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Àü½ÅÀû ÁúȯÀÚ ¹× ¿¹ÈÄ°¡ ºÒ·®ÇÑ È¯ÀÚ¿¡¼­ Valplast¢ç ź¼º ±¹¼ÒÀÇÄ¡ÀÇ Àû¿ë

Valplast¢ç flexible removable partial denture for a patient with medically compromised conditions : a clinical report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2009³â 47±Ç 3È£ p.295 ~ 300
ÃÖº½, ±è¼ºÈÆ, ÀÌ¿ø,
¼Ò¼Ó »ó¼¼Á¤º¸
ÃÖº½ ( Choi Bohm ) - °¡Å縯´ëÇб³ ÀÇÁ¤ºÎ¼º¸ðº´¿ø Ä¡°ú º¸Ã¶°ú
±è¼ºÈÆ ( Kim Seong-Hun ) - °¡Å縯´ëÇб³ ÀÇÁ¤ºÎ¼º¸ðº´¿ø Ä¡°ú º¸Ã¶°ú
ÀÌ¿ø ( Lee Won ) - °¡Å縯´ëÇб³ ÀÇÁ¤ºÎ¼º¸ðº´¿ø Ä¡°ú ±¸°­¾Ç¾È¸é¿Ü°ú

Abstract

¿¬±¸¸ñÀû: Çö´ëÀÇÇÐÀÇ ¹ß´Þ·Î °í·É Àα¸°¡ Áõ°¡ÇÔ¿¡ µû¶ó ºÎºÐ ¹«Ä¡¾ÇÀ̳ª ¿ÏÀü ¹«Ä¡¾Ç ȯÀÚÀÇ ºñÀ²ÀÌ Áõ°¡µÇ°í ÀÖ´Ù. °í·É ȯÀÚ´Â Àü½ÅÀû ÁúȯÀÌ µ¿¹ÝµÇ´Â °æ¿ì°¡ ÈçÇϹǷΠº¸Ã¶ Ä¡·á ½Ã¿¡µµ Àü½ÅÀûÀÎ °Ç°­ »óÅ ¹× °æÁ¦Àû ¿©°Ç¿¡ ´ëÇÑ °í·Á°¡ ÇÊ¿äÇÏ´Ù. °í·ÉÀÇ È¯ÀÚ³ª Àü½ÅÀû ÁúȯÀÚ¿¡ ÀÖ¾î ÀÓÇöõÆ® µîÀÇ Ä¡·áº¸´Ù °¡Ã¶¼º ±¹¼ÒÀÇÄ¡°¡ ¼±È£µÇ°í ½ÇÁ¦·Î ¸¹ÀÌ Àû¿ëµÇ°í ÀÖÀ¸³ª ±âÁ¸ÀÇ ±Ý¼Ó-¾ÆÅ©¸± ±¹¼ÒÀÇÄ¡´Â ¸¹Àº ÇÑ°èÁ¡À» °¡Áö°í ÀÖ´Ù. ÀüÄ¡ºÎ¿¡ ±Ý¼Ó Ŭ·¡½ºÇÁ°¡ À§Ä¡ÇÏ¿© ºñ½É¹ÌÀûÀÌ°í ¹ÌÁßÇÕ ·¹Áø¿¡ ÀÇÇÑ ¾Ë·¹¸£±â ¹ÝÀÀÀÌ ÀÖÀ¸¸ç Áö´ëÄ¡¿¡ °¡ÇØÁö´Â ÀÀ·ÂÀÌ Å©¸ç, ÆÄÀý ½Ã ¼ö¸®°¡ ¿ëÀÌÇÏÁö ¾Ê´Ù. ¶ÇÇÑ ´ëºÎºÐÀÇ °æ¿ì Áö´ëÄ¡¿¡ ÁÖÁ¶ ±Ý°üÀÇ Á¦ÀÛÀÌ ÇÊ¿äÇϸç ÀÌ·Î ÀÎÇØ Ãß°¡ÀûÀÎ °í°¡ÀÇ º¸Ã¶ºñ¿ëÀ» ºÎ´ãÇÏ¿©¾ß ÇÏ°í Á¦ÀÛ°úÁ¤ÀÌ º¹ÀâÇÒ »Ó ¾Æ´Ï¶ó Àå±â°£ÀÇ Ä¡·á¿Í ¿©·¯ ¹øÀÇ ³»¿øÀÌ ÇÊ¿äÇÏ´Ù. ¹Ý¸é, ÃÖ±Ù ÀÌ¿ëºóµµ°¡ Áõ°¡ÇÏ°í ÀÖ´Â Valplast¢ç ź¼º ±¹¼ÒÀÇÄ¡´Â Nylon ÀçÁú·Î »ýüģȭ¼ºÀÌ ³ô°í ½É¹ÌÀûÀÌ°í °¡º­¿ì¸ç ¼ö¸®°¡ ¿ëÀÌÇÑ ÀåÁ¡ÀÌ ÀÖ´Ù. ¶Ç °£´ÜÇÑ Áø·á °úÁ¤°ú ªÀº Á¦À۱Ⱓ ÈÄ ÀÇÄ¡¸¦ ÀåÂøÇÒ ¼ö ÀÖ´Ù. º» Áõ·Ê¿¡¼­´Â Àå±â°£ÀÇ Ä¡·á±â°£°ú ´Ù¼öÀÇ ³»¿øÀÌ ¾î·Á¿î Àü½Å ÁúȯÀÚ ¹× ¿¹ÈÄ°¡ ºÒ·®ÇÑ È¯ÀÚ¿¡¼­ Valplast¢ç ź¼º±¹¼ÒÀÇÄ¡¸¦ Àû¿ëÇÑ ¿¹¸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

°á°ú ¹× °á·Ð: Áõ·Ê¿¡¼­ ȯÀÚµéÀº ¸¸¼º Áúȯ, ¾Ï µîÀÇ Àü½ÅÀû, ¼Ò¸ð¼º ÁúȯÀ» ¾Î°í Àְųª °³±¸ Á¦ÇÑ ¶Ç´Â ¿¹ÈÄ°¡ ºÒ·®ÇÑ ÀÜÁ¸ Áö´ëÄ¡ µî Åë»óÀûÀÎ º¸Ã¶Ä¡·á°¡ Èûµç °æ¿ì¿´´Ù. ÀÌ·¯ÇÑ È¯Àڵ鿡°Ô ±âÁ¸ÀÇ ±Ý¼Ó-¾ÆÅ©¸± ±¹¼ÒÀÇÄ¡´Â ½ÅüÀûÀ¸·Î³ª °æÁ¦ÀûÀÎ ÀÌÀ¯·Î Àû¿ëÀÌ ¾î·Á¿ö ´ë½Å Ãß°¡ÀûÀÎ º¸Ã¶¹°ÀÇ Á¦ÀÛÀÌ ÇÊ¿ä ¾ø°í, Á¦ÀÛ°úÁ¤ÀÌ °£´ÜÇÑValplast¢ç ź¼º ±¹¼ÒÀÇÄ¡¸¦ Àû¿ëÇÏ¿´´Ù. ȯÀÚµéÀº Æò±Õ 1-2ȸÀÇ ÁÖ±âÀû üũ¸¦ Çß°í ÇöÀç±îÁö µ¿ÅëÀ̳ª ÆÄÀý µîÀÇ ºÒÆí°¨ÀÌ ¾øÀÌ Àß »ç¿ëÇÏ°í ÀÖ´Ù. ¿©·¯ Áõ·Ê¿¡¼­ ±âÁ¸ÀÇ °¡Ã¶¼º ÀÇÄ¡ÀÇ ´ÜÁ¡À» º¸¿ÏÇϴ ź¼ºÀÇÄ¡¸¦ ÀÌ¿ëÇÏ¿© ¸¸Á·ÇÑ °á°ú¸¦ ¾ò¾ú±â¿¡ º¸°íÇÏ´Â ¹ÙÀÌ´Ù.

Statement of problem: As the number of elders is growing with the advancement of medicine, partially or fully edentulous patients have increased. Medically compromised conditions are common in the older population so that it should be taken into account in prosthetic treatment planning as well as their economic conditions. In the older patients, removable prosthesis has been preferred to implant prosthesis. However, cast metal based removable partial dentures also has several limitations.

Purpose: In this report, we present several cases of Valplast¢ç flexible denture which were fabricated in patients who had medically compromised conditions or whose remaining teeth showed a relatively poor prognosis.

Results & Conclusion: This article describes an alternative treatment for a partially edentulous patient with mouth opening limitation, after cancer surgery, compromised general condition and questionable remaining teeth. In these patients, Valplast¢ç flexible denture was used because of its unique characteristics and the results were all satisfactory. Patients had 1-2 check-up and there were no postoperative pain or fracture of denture up to now.

Å°¿öµå

Àü½ÅÀû ÁúȯÀÚ;±Ý¼Ó-¾ÆÅ©¸± ±¹¼ÒÀÇÄ¡;Valplast¢çź¼º ±¹¼ÒÀÇÄ¡
medically compromised patients;cast metal based removable partial dentures;Valplast¢ç flexible partial denture

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed