Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Áö¸£ÄÚ´Ï¾Æ ¼¼¶ó¹ÍÀÇ Ç¥¸é󸮿¡ µû¸¥ Ä¡°ú¿ë Á¢ÂøÁ¦ÀÇ Àü´Ü°áÇÕ°­µµ

The effect of surface treatment conditioning on shear bond strength between zirconia and dental resin cements

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2013³â 51±Ç 2È£ p.73 ~ 81
±èÁöÇý, ¼­Àç¹Î, ¾È½Â±Ù, ¹ÚÁÖ¹Ì, ¼Û±¤¿±,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÁöÇý ( Kim Ji-Hae ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¼­Àç¹Î ( Seo Jae-Min ) - ÀüºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¾È½Â±Ù ( Ahn Seung-Geun ) - ÀüºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¹ÚÁֹ̠( Park Ju-Mi ) - ÀüºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¼Û±¤¿± ( Song Kwang-Yeob ) - ÀüºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¿¬±¸ ¸ñÀû:ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº Áö¸£ÄÚ´Ï¾Æ Ç¥¸é󸮿¡ µû¸¥ 3Á¾ÀÇ ·¹Áø½Ã¸àÆ®¿Í Áö¸£ÄڴϾÆÀÇ Àü´Ü°áÇÕ°­µµ¸¦ Æò°¡Çϱâ À§ÇÔÀÌ´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: ÃÑ 143°³ÀÇ µð½ºÅ© ¸ð¾çÀÇ Áö¸£ÄÚ´Ï¾Æ ºí·Ï(HASS Co., Gangneung, Korea) ½ÃÆíÀ» Á¦ÀÛÇÏ°í ÃÑ 13°³±º(n=11)À¸·Î ³ª´©¾ú´Ù. ±× Áß 9°³±ºÀº Ç¥¸éó¸® ¹æ½Ä(1. ¾Ë·ç¹Ì³ª ºÐ»ç, 2. ¾Ë·ç¹Ì³ª ºÐ»ç¿Í Áö¸£ÄÚ´Ï¾Æ ¶óÀ̳ÊÀÇ µµÆ÷, 3. ¾Ë·ç¹Ì³ª ºÐ»ç¿Í Rocatec (3M ESPE, Seefeld, Germany) ó¸®) ¹× »ç¿ëÇÑ 3Á¾·ùÀÇ ·¹Áø½Ã¸àÆ®(Bistite II (Tokuyama Dental Co., Japan), Panavia F2.0 (Kuraray Medical, Japan), Super-bond C&B (Sun Medical, Japan))¿¡ µû¶ó ³ª´©¾î ¿­¼øȯó¸® Àü Á¢Âø°­µµ ½ÇÇèÀ» ½ÃÇàÇÏ¿´´Ù. ¿­¼øȯó¸® Àü Á¢Âø°­µµ ½ÇÇèÀº À§ 3Á¾·ùÀÇ ·¹Áø½Ã¸àÆ®¸¦ 3°¡Áö ¹æ¹ýÀ¸·Î Ç¥¸éó¸®ÇÑ Áö¸£ÄÚ´Ï¾Æ ½ÃÆí¿¡ Á¢ÂøÇÏ°í, »ó¿ÂÀÇ Áõ·ù¼ö¿¡ 24½Ã°£ µ¿¾È º¸°üÇÑ ÈÄ, Àü´Ü°áÇÕ°­µµ¸¦ ÃøÁ¤ÇÏ¿´´Ù. ¿­¼øȯó¸® ÈÄ Á¢Âø°­µµ ½ÇÇèÀº, ¿­¼øȯó¸® Àü Á¢Âø°­µµ ½ÇÇè¿¡¼­ ¿ì¼öÇÑ Àü´Ü°áÇÕ°­µµ¸¦ º¸ÀÎ Áö¸£ÄÚ´Ï¾Æ Ç¥¸é󸮱º(¾Ë·ç¹Ì³ª ºÐ»ç¿Í Rocatec 󸮸¦ ÇÏ°í 3Á¾·ùÀÇ ·¹Áø½Ã¸àÆ®¸¦ Á¢ÂøÇÑ 3°³ÀÇ ±º)°ú ´ëÁ¶±ºÀ¸·Î ¾Ë·ç¹Ì³ª¸¸À¸·Î Ç¥¸éó¸® ÈÄ Super-bond C&B¸¦ Á¢ÂøÇÑ 1°³ÀÇ ±ºÀ» ´ë»óÀ¸·Î 5¡É¿Í 55¡É »çÀÌ¿¡¼­ 5,000ȸ ¿­¼øȯ󸮸¦ ½ÃÇàÇÏ°í Àü´Ü°áÇÕ°­µµ¸¦ ÃøÁ¤ÇÏ¿´´Ù.

°á°ú: ¿­¼øȯó¸® Àü Á¢Âø°­µµ ½ÇÇè¿¡¼­´Â ¾Ë·ç¹Ì³ª ºÐ»ç¿Í Rocatec 󸮸¦ ÇÑ Áö¸£ÄÚ´Ï¾Æ Ç¥¸é¿¡ Super-bond C&B¸¦ Á¢ÂøÇÑ ±ºÀÌ °¡Àå ³ôÀº Àü´Ü°áÇÕ°­µµ¸¦ º¸¿´´Ù. Super-bond C&B¸¦ »ç¿ëÇÑ ±ºÀÌ ´Ù¸¥ ½Ã¸àÆ® ±ºº¸´Ù À¯ÀǼº ÀÖ°Ô ³ôÀº Àü´Ü°áÇÕ°­µµ¸¦ º¸¿´À¸¸ç, Áö¸£ÄÚ´Ï¾Æ Ç¥¸é¿¡ Rocatec 󸮸¦ ÇÑ ±ºÀÌ ´Ù¸¥ Ç¥¸é󸮸¦ ÇÑ ±ºº¸´Ù À¯ÀǼº ÀÖ°Ô ³ôÀº Àü´Ü°áÇÕ°­µµ¸¦ º¸¿´´Ù. ¿­¼øȯ󸮸¦ ÇÑ ÈÄ¿¡´Â, Rocatec 󸮸¦ ÇÑ Áö¸£ÄÚ´Ï¾Æ Ç¥¸é¿¡ Super-bond C&B¸¦ Á¢ÂøÇÑ ±º¸¸ÀÌ À¯ÀÏÇÏ°Ô Àü´Ü°áÇÕ°­µµ°¡ Áõ°¡ÇÏ¿´À¸¸ç, ´Ù¸¥ ¸ðµç ±º¿¡¼­´Â Àü´Ü°áÇÕ°­µµ°¡ °¨¼ÒÇÏ¿´´Ù.

°á·Ð: º» ½ÇÇè¿¡¼­´Â Super-bond C&B ½Ã¸àÆ®°¡ °¡Àå ³ôÀº Àü´Ü°áÇÕ°­µµ¸¦ º¸¿´À¸¸ç, Rocatec ½Ã½ºÅÛÀº ·¹Áø½Ã¸àÆ®¿Í Áö¸£ÄڴϾÆÀÇ Àü´Ü°áÇÕ°­µµ¸¦ Çâ»ó½ÃÅ°´Â ¹æ¹ýÀÌ µÉ °ÍÀ̶ó°í »ç·áµÈ´Ù.

PURPOSE: The purpose of this study was to evaluate the effect of surface treatment on the shear bond strength of zirconia ceramic to 3 resin cements.

MATERIALS AND METHODS: A total of 143 disk-shaped Zirconia blocks (HASS Co., Gangneung, Korea) were randomly divided into three treatment groups: (1) only 50 §­ Al2O3 sandblasting, (2) 50 §­ Al2O3 sandblast and zircona liner, (3) 50 §­ Al2O3 sandblasting and Rocatec (3M ESPE, Seefeld, Germany). Bistite II (Tokuyama Dental Co., Japan), Panavia F (Kuraray Medical, Japan), and Superbond C&B (Sun Medical, Japan) were used to cement onto the zirconia. After 24h of storage in distilled water, shear bond strength was evaluated. High value group was re-tested after thermocycling at 5,000 cycles(5-55¡É). Shear bond strength data were analyzed with one-way ANOVA, two-way ANOVA test and Post Hoc Test (¥á=.05). Shear bond strength data before and after thermocycling were analyzed with Independent sample T test (¥á=.05).

RESULTS: Super-bond C&B treated with Rocatec showed the most high shear bond strength. Super-bond C&B groups resulted in significantly higher than other cement groups (P<.05). Rocatec groups resulted in significantly higher than other surface treatment groups (P<.05). Shear bond strength has increased in Panavia F treated with Zirconia liner (P<.05). After thermocycling, shear bond strength was increased in Super-bond C&B treated with Rocatec but decreased in other groups (P<.05).

CONCLUSION: Super-bond C&B cement resulted the highest shear bond strength and Rocatec system enhanced the shear bond strength. After thermocycling, shear bond strength has decreased in most resin cements except Super-bond C&B treated with Rocatec.

Å°¿öµå

Áö¸£ÄڴϾÆ; Àü´Ü°áÇÕ°­µµ; ¾Ë·ç¹Ì³ª ºÐ»ç; Áö¸£ÄÚ´Ï¾Æ ¶óÀ̳Ê; Rocatec
Zirconia; Shear bond strength; Sandblasting; Zirconia liner; Rocatec

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed