¾ç±Ø»êÈ­ ÀÓÇöõÆ® Ç¥¸é¿¡ Àû¿ëµÈ °ñÇü¼º´Ü¹éÁú°ú Ç÷°ü³»ÇǼ¼Æ÷¼ºÀåÀÎÀÚ°¡ °ñÀ¯Âø¿¡ ¹ÌÄ¡´Â ¿µÇâ: ¿¹ºñ¿¬±¸

Combined effects of rhBMP-2 and rhVEGF coated onto implants on osseointegration: pilot study

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2013³â 51±Ç 2È£ p.82 ~ 89
ÇãÁߺ¸, À±¹ÌÁ¤, Á¤Ã¢¸ð, ½Å»ó¿Ï, Àü¿µÂù,
¼Ò¼Ó »ó¼¼Á¤º¸
ÇãÁߺ¸ ( Huh Jung-Bo ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
À±¹ÌÁ¤ ( Yun Mi-Jung ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
Á¤Ã¢¸ð ( Jeong Chang-Mo ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
½Å»ó¿Ï ( Shin Sang-Wan ) - °í·Á´ëÇб³ ±¸·Îº´¿ø ÀÓ»óÄ¡ÀÇÇבּ¸¼Ò Ä¡°úº¸Ã¶°ú
Àü¿µÂù ( Jeon Young-Chan ) - ºÎ»ê´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¿¬±¸ ¸ñÀû:º» ¿¬±¸´Â ¾ç±Ø»êÈ­ ÀÓÇöõÆ®¿¡ °ñÇü¼º´Ü¹éÁú°ú Ç÷°ü³»ÇǼ¼Æ÷¼ºÀåÀÎÀÚ¸¦ ÄÚÆÃÇÑ ÀÓÇöõÆ®¸¦ Åä³¢ÀÇ °æ°ñ¿¡ ½Ä¸³ÇÏ¿© °ñ°ú ÀÓÇöõÆ® °è¸éÀÇ °ñÀ¯Âø Çâ»óÀÇ °¡´É¼ºÀ» Æò°¡ÇÏ°íÀÚ ½ÃÇàÇÏ¿´´Ù.

¿¬±¸ Àç·á ¹× ¹æ¹ý: 6¸¶¸®ÀÇ Åä³¢ ¾çÃø °æ°ñ¿¡ ÄÚÆÃÀ» ÇÏÁö ¾ÊÀº ¾ç±Ø »êÈ­ ÀÓÇöõÆ®(´ëÁ¶±º)¿Í °ñÇü¼º ´Ü¹éÁú°ú Ç÷°ü³»ÇǼ¼Æ÷¼ºÀåÀÎÀÚ¸¦ ÄÚÆÃÇÑ ÀÓÇöõÆ®(½ÇÇ豺)À» °¢°¢ ÇÑÂÊ¿¡ 2°³¾¿ ½Ä¸³ÇÏ¿´´Ù, Åä³¢´Â 2ÁÖ, 8ÁÖ¿¡ °¢°¢ 3¸¶¸®¾¿ Èñ»ýÇÏ¿´°í Àüü ½Ä¸³µÈ ÀÓÇöõÆ®´Â 24°³À̾ú´Ù. °¢ ½Ã±âº°, ±×·ìº° ÀÓÇöõÆ® ¼ö´Â °¢°¢ 6°³¾¿À̾ú´Ù. ÀÓÇöõÆ® ¾ÈÁ¤ Áö¼ö(resonance frequency analysis (RFA)), ȸÀü Á¦°Å·Â(Removable torque measurement (RTQ))À» Èñ»ý ½Ã±â¿¡ ÃøÁ¤ÇÏ¿´´Ù. µ¶¸³Ç¥º» t-test (SPSS Ver. 15.0, Chicago, USA)À» ÀÌ¿ëÇÏ¿© 2ÁÖ, 8ÁÖ¿¡¼­ ´ëÁ¶±º°ú ½ÇÇ豺ÀÇ Â÷À̸¦ ºñ±³ ºÐ¼®ÇÏ°í, À¯ÀǼöÁØ95%¿¡¼­ Åë°èÀûÀ¸·Î °ËÁ¤ÇÏ¿´´Ù.

°á°ú: ´ëÁ¶±º°ú ½ÇÇ豺 ¸ðµÎ 8ÁÖ¿¡¼­ ¿ì¼öÇÑ °ñÀ¯ÂøÀ» º¸¿´´Ù. ƯÈ÷ ½ÇÇ豺¿¡¼­ 8ÁÖ¿¡ ISQ, RTQ °ª ¸ðµÎ ´ëÁ¶±º°ú ºñ±³ÇÏ¿© ¿ì¼öÇÑ °ªÀ» ³ªÅ¸³»¾ú´Ù (P<.05). ÇÏÁö¸¸ 2ÁÖ¿¡¼­´Â µÎ±º »çÀÌ¿¡ Åë°èÀû À¯ÀǼºÀ» º¸ÀÌÁö ¾Ê¾Ò´Ù(P>.05).

°á·Ð: °ñÇü¼º ´Ü¹éÁú°ú Ç÷°ü³»ÇǼ¼Æ÷¼ºÀåÀÎÀÚ¸¦ ÀÓÇöõÆ® Ç¥¸é¿¡ ÄÚÆÃÇÏ¿© ½Ä¸³ÇÏ´Â °ÍÀº Ä¡À¯ÀÇ ÈĹݱ⿡ °ñÀ¯ÂøÀ» Áõ´ëÇÏ´Â °ÍÀ¸·Î »ç·áµÈ´Ù.

PURPOSE: The present study is aimed to evaluate the combined effect of recombinant human bone morphogenetic protein 2 (rhBMP-2) and recombinant human vascular endothelial growth factor (rhVEGF) coated onto anodized implants on osseointeration.

MATERIALS AND METHODS: Six New Zealand white rabbit were used in this study. Each animal received 4 implants that were either coated with rhBMP-2 and rhVEGF (Study group) or anodized implant (Control group) in both tibia. This was performed using a randomized split-mouth design. A total 24 implants were used. The implant stability quotient (ISQ) value using resonance frequency analyser and removal torque (RTQ) measurement were investigated at 2 and 8 weeks. The t-test was used for statistical analysis (¥á=.05).

RESULTS: Control and study group showed good osseointegration at 8 weeks. The ISQ and RTQ values of study group were significant compared with the control group at 8 weeks (P<.05). However, No statistical significance was observed at 2 weeks (P>.05).

CONCLUSION: It was concluded that rhBMP-2 with rhVEGF coated onto anodized implants can induce better osseointegration at late healing period.

Å°¿öµå

°ñÇü¼º ´Ü¹éÁú; Ç÷°ü³»ÇǼ¼Æ÷¼ºÀåÀÎÀÚ; ÀÓÇöõÆ® ¾ÈÁ¤Áö¼ö; ȸÀü Á¦°Å·Â; °ñÀ¯Âø
rhBMP-2; rhVEGF; Implant stability quotient; Removal torque; Osseointegration