Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

´Ù¼öÄ¡¾Æ¸¦ »ó½ÇÇÑ ¾ù°¥¸° ±³ÇÕ È¯ÀÚ¿¡¼­ ÀÓÇöõÆ®¿Í Locator(R) attachment¸¦ ÀÌ¿ëÇÑ °¡Ã¶¼º ±¹¼ÒÀÇÄ¡ Áõ·Ê

Removable partial denture restoration using single implant supported with Locator(R) attachment in a crossed occlusion patient: a case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2013³â 51±Ç 2È£ p.113 ~ 118
½Å¿îö, ¹æ¸ù¼÷, ¾çÈ«¼Ò, ¹Ú»ó¿ø, ÀÓÇöÇÊ, À±±Í´ö,
¼Ò¼Ó »ó¼¼Á¤º¸
½Å¿îö ( Shin Woon-Chul ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¹æ¸ù¼÷ ( Vang Mong-Sook ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¾çÈ«¼Ò ( Yang Hong-So ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
¹Ú»ó¿ø ( Park Sang-Won ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
ÀÓÇöÇÊ ( Lim Hyun-Pil ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
À±±Í´ö ( Yun Kwi-Dug ) - Àü³²´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç

Abstract

´Ù¼ö ÀÜÁ¸Ä¡¸¦ »ó½ÇÇÑ °æ¿ì ÀÜÁ¸Ä¡°£ÀÇ °ü°è°¡ ¿ªÇÐÀûÀ¸·Î ºÒ¸®ÇÑ »óȲ¿¡ ³õÀÏ ¼ö ÀÖ´Ù. ȯÀÚ°¡ ÀÇÄ¡¿¡ °üÇÑ °ÅºÎ°¨ÀÌ ¾øÀ» ¶§, ÀÌ·¯ÇÑ °æ¿ì ÇÇ°³ÀÇÄ¡¸¦ °í·ÁÇÒ ¼ö ÀÖÁö¸¸, ¹«Ä¡¾Ç ºÎÀ§¿¡ ÀÓÇöõÆ®¸¦ ÀÌ¿ëÇÔÀ¸·Î½á ¿ªÇÐÀûÀÎ ºÒ¸®ÇÔÀ» ±Øº¹ÇÏ°í ±¹¼ÒÀÇÄ¡ÀÇ ÁöÁö, ¾ÈÁ¤, À¯Áö¸¦ Çâ»ó½Ãų ¼ö ÀÖ´Ù. º» Áõ·Ê´Â ¼Ò¼ö ÀÜÁ¸Ä¡°£¿¡ ¾ù°¥¸° ±³ÇÕÀ» º¸À̴ ȯÀÚ·Î »ó¾Ç Ä¡¾Æ¿¡ ´ëÇյǴ ÇϾÇÀÇ ¹«Ä¡¾Ç ºÎÀ§¿¡ ´ÜÀÏ ÀÓÇöõÆ®¸¦ ½Ä¸³ÇÏ°í Locatorattachment¸¦ ¿¬°áÇÏ¿© »óÇÏ¾Ç ±¹¼ÒÀÇÄ¡·Î Ä¡·áÇÏ¿´´Ù. ±âÁ¸ÀÇ ±â¿ï¾îÁø ±³ÇÕÆò¸éÀ» ÀÌ»óÀûÀ¸·Î Àç¼³Á¤ÇÏ¿© ȯÀÚÀÇ ½É¹ÌÀû ¸¸Á·µµ¸¦ Çâ»ó½ÃÄ×´Ù. Ä¡·á ÀÌÈÄ 6°³¿ù°£ÀÇ ÀÓ»ó °üÂû¿¡¼­ ȯÀÚ´Â ½É¹ÌÀû, ±â´ÉÀûÀ¸·Î ¸¸Á·ÇÏ°í ¾ÈÁ¤ÀûÀ¸·Î À¯ÁöµÇ¾ú±â¿¡ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

When losing many of the remaining teeth, the relation among them can be put into dynamically unfavorable situation. In the case that the patient without any incompatibility to the denture, overdenture can be considered. Moreover, we can overcome the dynamical disadvantage, and improve the support, stability, and retention of the partial denture by using implant at the edentulous area. In this case, patient with crossed occlusion between few remaining teeth was treated with maxillary and mandibular partial denture. Single implant fixture was placed at the edentulous space, opposing to the maxillary teeth occluded, and Locator attachment was connected. The patient's esthetic satisfaction was improved by ideally adjusting the tilted occlusal plane. Since the patient was satisfied both esthetically and functionally, and maintained stable during the clinical observation for 6 months after the treatment, we would like to report about it.

Å°¿öµå

¾ù°¥¸° ±³ÇÕ; ÀÓÇöõÆ®¸¦ ÀÌ¿ëÇÑ ±¹¼ÒÀÇÄ¡; Locator attachment
Crossed occlusion; Partial denture using implant; Locator attachment

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed