ÀλóäµæÀÌ °¡´ÉÇÑ Ä¡À¯Áö´ëÁÖ¸¦ ÀÌ¿ëÇÑ ÀÓÇöõÆ® ÀλóäµæÀÇ Á¤È®¼º

Accuracy of the healing abutment and impression coping combined system on implant impression

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2015³â 53±Ç 2È£ p.105 ~ 110
Àü°æ¹è, À̵ÎÇü, ±èÁ¤ÇÑ, ȲÁØÈ£, ¹ÚÇöÀ§, À̱Ժ¹,
¼Ò¼Ó »ó¼¼Á¤º¸
Àü°æ¹è ( Jeon Kyoung-Bae ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
À̵ÎÇü ( Lee Du-Hyeong ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç
±èÁ¤ÇÑ ( Kim Jung-Han ) - (ÁÖ) RaphaBio
ȲÁØÈ£ ( Hwang Jun-Ho ) - (ÁÖ) RaphaBio
¹ÚÇöÀ§ ( Park Hyun-We ) - (ÁÖ) RaphaBio
À̱Ժ¹ ( Lee Kyu-Bok ) - °æºÏ´ëÇб³ Ä¡ÀÇÇÐÀü¹®´ëÇпø Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¸ñÀû: »õ·Ó°Ô °³¹ßµÈ ÀλóäµæÀÌ °¡´ÉÇÑ Ä¡À¯Áö´ëÁÖ¸¦ ÀÌ¿ëÇÑ Àλóäµæ°ú ±âÁ¸ÀÇ ÀÓÇÁ·¹¼Ç ÄÚÇÎÀ» ÀÌ¿ëÇÑ ÀλóäµæÀ» 3Â÷¿øÀûÀ¸·Î ºñ±³ÇÔÀ¸·Î½á °³¹ßµÈ ½Ã½ºÅÛÀÇ Á¤È®¼ºÀ» Æò°¡ÇÏ¿´´Ù.

Àç·á ¹× ¹æ¹ý: 10¸íÀÇ È¯ÀÚ¿¡¼­ ±¸Ä¡ºÎ¿¡ ÀÓÇöõÆ®(SuperLine; Dentium, Seoul, Korea)¸¦ ½Ä¸³ ÈÄ Ä¡À¯Áö´ëÁÖ(MyHealing; Raphabio Co., Seoul, Korea)¸¦ ¿¬°áÇÏ¿´´Ù. ½Ä¸³ 3°³¿ù ÈÄ º¸Ã¶¹° Á¦ÀÛÀ» À§ÇÑ Àλóäµæ½Ã ÀλóäµæÀÌ °¡´ÉÇÑ Ä¡À¯Áö´ëÁÖ¸¦ ÀÌ¿ëÇÑ transfer ¹æ½Ä°ú ±âÁ¸ÀÇ Àλó¿ë ÄÚÇÎÀ» ÀÌ¿ëÇÑ pick-up ¹æ½ÄÀ¸·Î µÎ ¹ø Àλóäµæ ÈÄ °¢°¢ ÁÖ¸ðÇüÀ» Á¦ÀÛÇÏ¿´´Ù. ¸ÂÃãÇü º¸Ã¶ Áö´ëÁÖ(Myplant; Raphabio Co., Seoul, Korea)¸¦ Á¦ÀÛÇÏ°í °¢°¢ÀÇ ÁÖ¸ðÇü¿¡ ü°á ÈÄ Ä¡°ú¿ë ½ºÄ³³Ê(Scanner S600; Zirkonzahn, South Tyrol, Italy)·Î °¡»óÀÇ ¸ðÇüÀ» Çü¼ºÇÏ¿´´Ù. 3Â÷¿ø ºÐ¼® ÇÁ·Î±×·¥(Geomagic Qualify 12; Geomagic, Morrisville, NC, USA)À» ÀÌ¿ëÇÏ¿© µÎ °³ÀÇ °¡»óÀÇ ¸ðÇüÀ» ÁßøÇÏ¿© Áö´ëÁÖÀÇ À§Ä¡¿Í ±â¿ï±âÀÇ Â÷À̸¦ ºÐ¼®ÇÏ¿´´Ù. ÃøÁ¤°ªÀº Kruskal Wallis°ú Mann-Whitney U test ¹æ¹ýÀ» ÅëÇØ ºÐ¼®ÇÏ¿´°í, À¯ÀǼöÁØÀº 0.05 ·Î ¼³Á¤ÇÏ¿´´Ù.

°á°ú: µÎ °¡Áö Àλó¹ý¿¡ µû¸¥ Áö´ëÁÖÀÇ À§Ä¡´Â ±Ù¿ø½É ¹æÇâ¿¡¼­ 0.032 mm, Çù¼³Ãø ¹æÇâ¿¡¼­ 0.029 mm, »óÇÏ ¹æÇâ¿¡¼­ 0.023 mmÀÇ Â÷À̸¦ º¸¿´´Ù. ±â¿ï±â´Â ±Ù¿ø½É ¹æÇâ¿¡¼­ 0.755??, Çù¼³Ãø ¹æÇâ¿¡¼­ 1.275??, »óÇÏ ¹æÇâ¿¡¼­ 0.420??ÀÇ Â÷À̸¦ º¸¿´´Ù.

°á·Ð: ÀλóäµæÀÌ °¡´ÉÇÑ Ä¡À¯Áö´ëÁÖ¸¦ ÀÌ¿ëÇÑ Àλóäµæ ¹æ½ÄÀº ±âÁ¸ÀÇ ÀüÅëÀûÀÎ Àλó¿ë ÄÚÇÎÀ» ÀÌ¿ëÇÑ ¹æ½Ä°ú ºñ±³ ½Ã 0.032 mm À̳»ÀÇ Â÷À̸¦ º¸¿´°í ±âÁ¸ ³í¹®°úÀÇ ºñ±³ ½Ã À¯»çÇÑ ¼öÄ¡ÀÌ´Ù.

PURPOSE: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression.

MATERIALS AND METHODS: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (¥á=.05).

RESULTS: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were 0.755??in sagittal plane, and 1.275??in coronal plane, and 0.420??in horizontal plane.

CONCLUSION: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Å°¿öµå

ÀÓÇöõÆ®; Ä¡À¯Áö´ëÁÖ; Àλóäµæ; Á¤È®¼º
Implant; Healing abutment; Impression taking; Accuracy