Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

¹«Ä¡¾Ç ȯÀÚ¿¡¼­ ±â¼º Á¶¸³½Ä bar¸¦ ÀÌ¿ëÇÑ ÀÓÇöõÆ® ÇÇ°³ÀÇÄ¡ Áõ·Ê

Implant-retained overdentures with pre-fabricated bar attachment system in edentulous patients

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2016³â 54±Ç 1È£ p.41 ~ 48
¼Ò³ª¿µ, È«¿µ±â, ÇϽ·æ,
¼Ò¼Ó »ó¼¼Á¤º¸
¼Ò³ª¿µ ( So Na-Young ) - ¾ÆÁÖ´ëÇб³ Ä¡°úÇб³½Ç
È«¿µ±â ( Hong Young-Gi ) - ¾ÆÁÖ´ëÇб³ Ä¡°úÇб³½Ç
ÇϽ·æ ( Ha Seung-Ryong ) - ¾ÆÁÖ´ëÇб³ Ä¡°úÇб³½Ç

Abstract

Ä¡¾Æ »ó½Ç¿¡ ÀÌ¾î ½É°¢ÇÑ Ä¡Á¶°ñ ¼Ò½ÇÀ» º¸ÀÌ´Â ¹«Ä¡¾Ç ȯÀÚµéÀº ÀüÅëÀûÀÎ ¹æ½ÄÀÇ ÃÑÀÇÄ¡¸¦ »ç¿ëÇϴµ¥ ¾î·Á¿òÀÌ ¸¹´Ù. ÀÌ·¯ÇÑ ¹®Á¦¸¦ º¸¿ÏÇÒ ¼öÀÖµµ·Ï ÀÓÇöõÆ®¸¦ ÀÌ¿ëÇÑ ÇÇ°³ÀÇÄ¡°¡ »ç¿ëµÇ°í ÀÖ´Ù. SFI-bar´Â Áø·á½Ç¿¡¼­ Á÷Á¢ Á¶Á¤ÀÌ °¡´ÉÇÑ ±â¼ºÇ°À¸·Î º¹ÀâÇÑ ±â°ø°úÁ¤À» ÇÊ¿ä·Î ÇÏ´Â ±âÁ¸ÀÇ ¹Ù ½Ã½ºÅÛº¸´Ù °£°áÇÏ¿© ½Ã°£°ú ºñ¿ëÀ» Àý°¨ÇÒ ¼ö ÀÖ´Ù. ù ¹ø° Áõ·Ê´Â 55¼¼ ³²ÀÚ È¯ÀÚ·Î ±âÁ¸ ÇÏ¾Ç ÀÓÇöõÆ®-ÁöÁö ÇÇ°³ÀÇÄ¡°¡ ÆÄÀýµÇ¾ú´Ù´Â ÁÖ¼Ò·Î ³»¿øÇÏ¿´°í ³»±¸¼ºÀÌ ÀÖÀ¸¸ç ÅëÁõÀÌ ¾ø´Â ÀÇÄ¡¸¦ ¿øÇÏ¿´´Ù. ÆÄÀýµÈ Locator ¾îÅÂÄ¡¸ÕÆ®¸¦ Á¦°Å ÈÄ ¹Ù¸¦ ÀÌ¿ëÇÑ ÇÇ°³ÀÇÄ¡·Î Ä¡·áÇÏ¿´´Ù. µÎ ¹ø° Áõ·Ê´Â ÆÄŲ½¼º´À» ¾Î°í ÀÖ´Â 77¼¼ ¿©ÀÚ È¯ÀÚ·Î ÇÏ¾Ç Ä¡Á¶°ñÀÌ ½É°¢ÇÏ°Ô Èí¼öµÇ¾î ÀÇÄ¡°¡ ÀÚÁÖ Å»¶ôÇÑ´Ù´Â ÁÖ¼Ò·Î ³»¿øÇÏ¿´°í ÅëÁõÀÌ ¾ø°í À¯Áö·ÂÀÌ ÀÖ´Â ÀÇÄ¡¸¦ ¿øÇÏ¿´´Ù. ÇÏ¾Ç ÀüÄ¡ºÎ¿¡ µÎ°³ÀÇ ÀÓÇöõÆ®¸¦ ½Ä¸³ÇÑ ÈÄ ÀÓÇöõÆ®¿¡ ¿¬°áµÈ ¾î´ðÅÍ¿¡ ¹Ù¸¦ ¿¬°áÇÏ¿´´Ù. ±× ÈÄ ¹Ù¿¡ ¸Â´Â ¿©¼ººÎ¸¦ »õ·Î¿î ÀÇÄ¡¿¡ ÀåÂøÇÏ¿© Ä¡·áÇÏ¿´´Ù. 2³âÀÇ ÃßÀû °üÂû °á°ú »ó±â ȯÀÚ ¸ðµÎ ½É¹ÌÀû, ±â´ÉÀûÀ¸·Î ¸¸Á·ÇÒ¸¸ÇÑ °á°ú¸¦ º¸¿´À¸¹Ç·Î Áõ·Ê¸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

Edentulous patients with severe alveolar bone resorption have trouble with using traditional complete denture. In order to overcome these problems, implant-retained overdenture was developed. SFI-bar system can save time and cost compared to other existing bar systems which need complicated laboratory procedures because it can be adjusted directly in a patient`s mouth. A 55-year-old male, who had experienced a fractured lower old implant-retained overdenture, wanted a durable and painless denture. The fractured Locator attachments were removed and edentulous mandible was restored with SFI-bar. A 77-year-old female with a medical history of the Parkinson`s disease and severely absorbed alveolar bone of mandible, wanted to wear a retentive mandibular denture without pain. After placing two implants in front of mental foramen, two adaptors were connected to two implants and a tube bar was connected to the adaptors. A female part fitted to the bar was attached to the new denture. These clinical reports describe two-implant-retained overdenture using the SFI-bar system in mandibular edentulous patients. Since the patients were satisfied esthetically and functionally during 2 years` observation, we would like to report cases.

Å°¿öµå

±â¼º¹Ù¾îÅÂÄ¡¸ÕÆ®; SFI-bar; ÇÇ°³ÀÇÄ¡; Ä¡°úÀÓÇöõÆ®
Prefabricated bar attachement; SFI-bar; Overdenture; Dental implant

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed