Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

µÎ Á¾·ùÀÇ ÀÓÇöõÆ® ½Ã½ºÅÛÀ» ÀÌ¿ëÇÑ ÇϾÇÀÇ ¹Ì´Ï-ÀÓÇöõÆ®ÁöÁö ÇÇ°³ÀÇÄ¡ ¼öº¹ Áõ·Ê

Mandibular implant supported overdentures with two different mini-implant systems: A case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2016³â 54±Ç 3È£ p.267 ~ 272
¹ÚÁøÈ«, ÀÌÁ¤¿­, ·ùÀçÁØ, ½Å»ó¿Ï,
¼Ò¼Ó »ó¼¼Á¤º¸
¹ÚÁøÈ« ( Park Jin-Hong ) - °í·Á´ëÇб³ ±¸·Îº´¿ø ÀÓ»óÄ¡ÀÇÇבּ¸¼Ò
ÀÌÁ¤¿­ ( Lee Jeong-Yol ) - °í·Á´ëÇб³ ±¸·Îº´¿ø ÀÓ»óÄ¡ÀÇÇבּ¸¼Ò
·ùÀçÁØ ( Ryu Jae-Jun ) - °í·Á´ëÇб³ ¾È¾Ïº´¿ø Ä¡°ú º¸Ã¶°ú
½Å»ó¿Ï ( Shin Sang-Wan ) - °í·Á´ëÇб³ ±¸·Îº´¿ø ÀÓ»óÄ¡ÀÇÇבּ¸¼Ò

Abstract

º» Áõ·Ê´Â Ä¡Á¶°ñÀÇ Èí¼ö°¡ ½ÉÇÑ µÎ ¸íÀÇ ¿ÏÀü¹«Ä¡¾Ç ȯÀÚ¿¡¼­ ¼­·Î ´Ù¸¥ ÀÓÇöõÆ® ½Ã½ºÅÛÀ» ÀÌ¿ëÇÑ ÇϾÇÀÇ ¹Ì´Ï-ÀÓÇöõÆ® ÁöÁö ÇÇ°³ÀÇÄ¡¿¡ ´ëÇÑ Áõ·Êº¸°íÀÌ´Ù. µÎ ȯÀÚ´Â ÇÏ¾Ç ÀÇÄ¡ÀÇ À¯Áö·Â ºÎÁ·À¸·Î ÀÎÇÑ ÀÇÄ¡ »ç¿ë½Ã ºÒÆí°¨ ¹× µ¿ÅëÀ» ÁּҷΠȣ¼ÒÇÏ¿´´Ù. °¢°¢ÀÇ È¯ÀÚ´Â 4°³ÀÇ ¹Ì´Ï ÀÓÇöõÆ®¸¦ ÀÌ°ø»çÀÌ¿¡ ÆǸ·ÀÇ °Å»ó¾øÀÌ ½Ä¸³ÇÏ¿´´Ù. ù¹ø° Áõ·Ê´Â ¹Ì´Ïº¼ ¾îÅÂÄ¡¸ÕÆ®¿Í ÀÏüÇüÀ¸·Î µÈ ¹Ì´Ï-ÀÓÇöõÆ®(Slimline, Dentium, Seoul, Korea)¸¦ ½Ä¸³ÇÏ°í ±¸°­³» Á÷Á¢¹ýÀ¸·Î ¾îÅÂÄ¡¸ÕÆ®¸¦ ¿¬°áÇÏ¿© Áï½ÃÇÏÁßÀ» ½ÃÇàÇÏ¿´´Ù. µÎ¹ø° Áõ·Ê´Â ºÐ¸®ÇüÀ¸·Î ·ÎÄÉÀÌÅÍ ¾îÅÂÄ¡¸ÕÆ®¿Í ¿¬°áµÇ´Â ¹Ì´Ï-ÀÓÇöõÆ®(LODI, Zest Anchors, Escondido, CA, USA)¸¦ ÀÌ¿ëÇÏ¿´À¸¸ç, ÀÓÇöõÆ® ½Ä¸³ 8ÁÖ ÈÄ °£Á¢¹ýÀ¸·Î ¾îÅÂÄ¡¸ÕÆ®¸¦ ¿¬°áÇÏ¿´´Ù. ÃÖÁ¾ ÀÇÄ¡ ÀåÂø ÈÄ 6°³¿ù Á¤±â°ËÁø±îÁö ¹Ì´Ïº¼°ú ·ÎÄÉÀÌÅÍ ¾îÅÂÄ¡¸ÕÆ®¸¦ ÀÌ¿ëÇÑ ÇϾÇÀÇ ¹Ì´Ï-ÀÓÇöõÆ® ÁöÁö ÇÇ°³ÀÇÄ¡ Áõ·Ê¿¡¼­ ȯÀÚÀÇ Àü¹ÝÀûÀÎ ¸¸Á·µµ°¡ °³¼±µÇ¾úÀ¸¸ç ÁÖ¸ñÇÒ ¸¸ÇÑ ÇÕº´Áõ ¾øÀÌ ¸¸Á·ÇÒ ¸¸ÇÑ ÀÓ»óÀû °á°ú¸¦ ¾ò¾ú´Ù. ´Ü ÃßÈÄ Áö¼ÓÀûÀÎ À¯Áö°ü¸® ¹× Àå±âÀûÀÎ Æò°¡°¡ ´õ ÇÊ¿äÇϸ®¶ó »ç·áµÈ´Ù.

This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator¡¯s metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.

Å°¿öµå

¹Ì´Ï-ÀÓÇöõÆ®; ÇÇ°³ÀÇÄ¡; Áï½ÃÇÏÁß; ¾îÅÂÄ¡¸ÕÆ®
implant; Overdenture; Immediate loading; Attachment

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed