Radiographic evaluation of computer aided design/computer aided manufacturing (CAD/CAM) customized abutment of implant

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2017³â 55±Ç 3È£ p.258 ~ 263
À±Å°æ, ÀÌ°æÁ¦, Á¤ÀçÇå, ±èÈñÁß,
¼Ò¼Ó »ó¼¼Á¤º¸
À±Å°æ ( Yun Tae-Gyeong ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
ÀÌ°æÁ¦ ( Lee Gyeong-Je ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
Á¤ÀçÇå ( Chung Chae-Heon ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
±èÈñÁß ( Kim Hee-Jung ) - Á¶¼±´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¸ñÀû: À̹ø ¿¬±¸¿¡¼­, ´Ù¾çÇÑ »óȲ¿¡¼­ °ñ¼Ò½Ç¾çÀ» Æò°¡Çϱâ À§ÇÏ¿© ¸ÂÃãÇü Áö´ëÁÖ¸¦ »ç¿ëÇÑ È¯ÀÚ¿¡¼­ 4³â°£ÀÇ ÈÄÇâÀû ¹æ»ç¼±ÇÐÀûÀÎ ¿¬±¸¸¦ ½ÃÇàÇÏ¿´´Ù.

´ë»ó ¹× ¹æ¹ý: À̹ø ¿¬±¸ÀÇ ´ë»óÀº CAD/CAM ¸ÂÃãÇü Áö´ëÁÖ¸¦ ÀÌ¿ëÇÑ ÀÓÇöõÆ® °íÁ¤¼º º¸Ã¶¹°ÀÌ´Ù. 2011³â 8¿ù 1ÀϺÎÅÍ 2012³â 7¿ù 31ÀÏ ±îÁö Á¶¼±´ëÇб³ Ä¡°úº´¿ø º¸Ã¶°ú¿¡¼­ Á¦ÀÛÇÏ¿© °íÁ¤¼º º¸Ã¶¹°·Î »ç¿ëµÈ CAD/CAM ¸ÂÃãÇü Áö´ëÁÖ¿Í »óºÎ º¸Ã¶¹°µéÀ» ´ë»óÀ¸·Î ÇÏ¿´À¸¸ç, °íÁ¤¼º º¸Ã¶¹°À» Á¦ÀÛÇÑ È¯ÀÚ¿¡ ´ëÇÏ¿© ¹æ»ç¼±ÇÐÀû Æò°¡¸¦ ½ÃÇàÇÏ¿© º¸Ã¶¹° ÀåÂø ÈÄ 3°³¿ù, 6°³¿ù, 1³â, 2³â, 3³â, 4³â ´ÜÀ§·Î ÃÑ 4³â °£ÀÇ ÈÄÇâÀû ¿¬±¸¸¦ ½ÃÇàÇÏ¿´´Ù.

°á°ú: ¿¬±¸ °á°ú, CAD/CAMÀ» ÀÌ¿ëÇÑ ¸ÂÃãÇü Áö´ëÁÖ´Â ±âÁ¸ ¿¬±¸ °á°ú¿¡ ºñÇØ °ñ¼Ò½Ç ¾çÀÌ Àû¾ú´Ù. ¿¬°á °íÁ¤µÈ ±×·ì°ú ¿¬°á °íÁ¤µÇÁö ¾ÊÀº ±×·ì °£¿¡ °ñ¼Ò½Ç ¾ç(°¢°¢ 0.27 mm, 0.5 mm)¿¡ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾ú´Ù. ¶ÇÇÑ »ó¾Ç ÀüÄ¡ºÎ, »ó¾Ç ±¸Ä¡ºÎ, ÇÏ¾Ç ÀüÄ¡ºÎ, ÇÏ¾Ç ±¸Ä¡ºÎÀÇ ºÎÀ§º° °ñ¼Ò½Ç¾ç(°¢°¢ 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm)¿¡ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ÀÖ¾ú´Ù.

°á·Ð: CAD/CAMÀ» ÀÌ¿ëÇÑ ¸ÂÃãÇü Áö´ëÁÖ´Â ¿¬°á °íÁ¤ ¿©ºÎ¿¡ µû¸¥ °ñ¼Ò½Ç ¾ç¿¡¼­ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾úÀ¸¸ç, ÀÓÇöõÆ® ½Ä¸³ ºÎÀ§¿¡ µû¸¥ °ñ¼Ò½Ç ¾ç¿¡¼­ Åë°èÀûÀ¸·Î À¯ÀÇÇÑ Â÷ÀÌ°¡ ÀÖ¾ú´Ù.

PURPOSE. In this study, the retrospective radiographic study is executed to evaluate amount of bone loss of various conditions in patients using customized abutment for 4 years of follow-up.

MATERIALS AND METHODS. The subjects of this study were implant fixed dental prosthesis using CAD/CAM customized abutments. CAD/CAM customized abutment and fixed dental prosthesis were manufactured by the Prosthodontics Department of Chosun University Dental Hospital from August 1, 2011 to July 31, 2012. Radiological assessments were performed on the patients who were treated by the fixed prosthodontics. After each treatment, a retrospective study was performed for a total of 4 years at 3 months, 6 months, 1 year, 2 years, 3 years, and 4 years.

RESULTS. As a result of the study, the customized abutment using CAD/CAM showed less bone loss than the results of existing research. There was no statistically significant differences at alveolar bone loss between splinting group and non-splinting group (respectively 0.27 mm, 0.5 mm). Also, there were statistically significant differences at alveolar bone loss in mx. anterior, mx. posterior, mn. anterior and mn. posterior part (respectively 1.37 mm, 0.39 mm, 0.00 mm, 0.30 mm).

CONCLUSION. The customized abutment using CAD/CAM showed less bone loss than the results of existing research, there were statistically significant differences at alveolar bone loss in implant positions.

Å°¿öµå

ijµåÄ·; ÀÓÇöõÆ® Áö´ëÁÖ; Ä¡Á¶°ñ¼Ò½Ç; ¹æ»ç¼± »çÁø
CAD/CAM; Dental implant abutment; Alveolar bone loss; X-ray