Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Áö´ëÁÖ È¤Àº Áö´ëÁÖ ³ª»ç ÆÄÀýÀÌ ¹ß»ýÇÑ ÀÓÇöõÆ® º¸Ã¶¹°¿¡¼­ È¿°úÀûÀÎ ¼ö¸® ¹æ¹ý

Repairment of abutment and abutment screw fracture in implant prosthesis: A case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2019³â 57±Ç 1È£ p.37 ~ 41
±èÁ¦ÈÆ, À¯ÁøÁÖ, ±è¸¸¿ë, À±ÁØÈ£,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÁ¦ÈÆ ( Kim Jae-Hoon ) - ±¹¹Î°Ç°­º¸Çè Àϻ꺴¿ø Ä¡°úº¸Ã¶°ú
À¯ÁøÁÖ ( Yoo Jin-Joo ) - ±¹¹Î°Ç°­º¸Çè Àϻ꺴¿ø Ä¡°úº¸Ã¶°ú
±è¸¸¿ë ( Kim Man-Yong ) - ±¹¹Î°Ç°­º¸Çè Àϻ꺴¿ø Ä¡°úº¸Ã¶°ú
À±ÁØÈ£ ( Yoon Joon-Ho ) - ±¹¹Î°Ç°­º¸Çè Àϻ꺴¿ø Ä¡°úº¸Ã¶°ú

Abstract

Ä¡°ú ÀÓÇöõÆ®´Â »ó½ÇµÈ Ä¡¾ÆÀÇ ¼öº¹¿¡ È¿°úÀûÀÌ°í ¿¹Ãø °¡´ÉÇÑ Ä¡·á ¹æ¹ýÀÌ´Ù. ÇÏÁö¸¸ ÀÓÇöõÆ® »ç¿ëÀÌ Áõ°¡ÇÔ¿¡ µû¶ó ÇÕº´Áõµµ Áõ°¡ÇÏ°í ÀÖ´Ù. ÀÌÁß ±â°èÀû ÇÕº´ÁõÀº ¹ß»ý ºóµµ°¡ ³ôÀ» »Ó ¾Æ´Ï¶ó ÀÓÇöõÆ®ÀÇ ¼ö¸íÀÌ ±æ¾îÁú¼ö·Ï ´õ ¸¹ÀÌ ¹ß»ýÇϹǷΠÀÌ¿¡ ´ëÇÑ ´ëÃ¥ÀÌ ÇÊ¿äÇÏ´Ù. ÀÌ¿¡ ÀÓÇöõÆ®ÀÇ °¡Àå ÈçÇÑ ±â°èÀû ÇÕº´ÁõÀÎ Áö´ëÁÖ ÆÄÀý°ú Áö´ëÁÖ ³ª»ç ÆÄÀýÀÇ Áõ·Ê¿¡¼­ ÆÄ¼ÕµÈ ºÎÀ§¸¸ ÀçÁ¦ÀÛÇÏ¿© ÆļյÇÁö ¾ÊÀº ±¸¼º¿ä¼Ò¸¦ ÃÖ´ëÇÑ º¸Á¸ÇÒ ¼ö ÀÖ´Â ¹æ¹ýÀ» ¼Ò°³ÇÏ°íÀÚ ÇÑ´Ù.

Dental implants are an effective and predictable treatment for restoration of missing teeth. However, as the use of implants increases, complications are also increasing. The mechanical complications are not only highly frequent, but also increasing as life span of an implant increases, thus, solutions should be prepared. In this report, we will present a case dealing with abutment fracture and abutment screw fracture which are the most common mechanical complication of the implant, focusing on preserving and reusing existing components by reconstructing only the damaged parts.

Å°¿öµå

ÀÓÇöõÆ® º¸Ã¶¹°; Áö´ëÁÖ ÆÄÀý; Áö´ëÁÖ ³ª»ç ÆÄÀý
Implant prosthesis; Implant abutment fracture; Abutment screw fracture