Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

µðÁöÅÐ º¹Á¦·Î ¸¸µç ¸ÂÃãÇü ÀΰøÄ¡·Î Á¦ÀÛÇÑ ÀÓ½ÃÀÇÄ¡¿Í ÀÓÇöõÆ® ¼ö¼ú¿ë ÅÛÇø´À» ÅëÇÑ ÀÓÇöõÆ® ÁöÁöÇü °íÁ¤¼º º¸Ã¶ ¼öº¹ Áõ·Ê

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report

´ëÇÑÄ¡°úº¸Ã¶ÇÐȸÁö 2019³â 57±Ç 4È£ p.397 ~ 404
Á¤´ë±æ, ¿À°æö, ½ÉÁؼº, ¹ÚÁö¸¸,
¼Ò¼Ó »ó¼¼Á¤º¸
Á¤´ë±æ ( Jeong Dae-Gil ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
¿À°æö ( Oh Kyung-Chul ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
½ÉÁؼº ( Shim June-Sung ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç
¹ÚÁö¸¸ ( Park Ji-Man ) - ¿¬¼¼´ëÇб³ Ä¡°ú´ëÇÐ Ä¡°úº¸Ã¶Çб³½Ç

Abstract

¼º°øÀûÀÎ ÀÓÇöõÆ® Ä¡·á¸¦ À§Çؼ­´Â ½Ä¸³ºÎÀ§ÀÇ °ñÁ¶Á÷ ¹× ¿¬Á¶Á÷ »óÅÂ(condition)µµ Áß¿äÇÏÁö¸¸ ½Ä¸³ À§Ä¡ ¶ÇÇÑ ¸Å¿ì Áß¿äÇÏ´Ù. À߸øµÈ À§Ä¡¿¡ ½Ä¸³µÈ ÀÓÇöõÆ®´Â »ý¹°ÇÐÀû, ½É¹ÌÀû, ±â°èÀû ¹®Á¦Á¡À» ¾ß±âÇÏ°Ô µÈ´Ù. ¿Ã¹Ù¸¥ À§Ä¡¿¡ ÀÓÇöõÆ®¸¦ ½Ä¸³Çϱâ À§Çؼ­´Â ÃÖÁ¾ º¸Ã¶¹°À» °í·ÁÇØ¾ß Çϸç À̸¦ À§Çؼ­´Â Áø´Ü ¿Î½º¾÷ °úÁ¤ÀÌ ÇÊ¿äÇÏ´Ù. ¹ßÄ¡ ÈÄ »ç¿ë ÇÒ Àӽà ÀÇÄ¡ÀÇ ÀΰøÄ¡¸¦ Áø´Ü ¿Î½º¾÷ ÇüÅ´ë·Î Á¦ÀÛÇÏ¸é ±¸°­³»¿¡¼­ Áø´Ü ¿Î½º¾÷ ÇüŸ¦ Æò°¡ÇØ º¼ ¼ö ÀÖÀ¸¸ç, Àß ÀûÀÀµÈ Àӽà ÀÇÄ¡¸¦ º¹Á¦ÇØ Á¦ÀÛÇÑ ÀÓÇöõÆ® ¼ö¼ú¿ë ÅÛÇø´À¸·Î °èȹµÈ À§Ä¡¿¡ ÀÓÇöõÆ®¸¦ ½Ä¸³ÇÏ´Â °ÍÀÌ °¡´ÉÇÏ´Ù. º» Áõ·Ê¿¡¼­´Â Áø´Ü ¿Î½º¾÷À» µðÁöÅÐ º¹Á¦ÇÏ¿© ÀÇÄ¡¿ë ÀΰøÄ¡¸¦ ¸ÂÃãÇüÀ¸·Î Á¦ÀÛÇÏ¿´°í, À̸¦ ÀÌ¿ëÇØ Àӽà ÀÇÄ¡¸¦ Á¦ÀÛÇÏ¿´´Ù. ÃæºÐÇÑ ÀûÀÀ ±â°£À» °ÅÄ£ ÈÄ Àӽà ÀÇÄ¡¸¦ º¹Á¦ÇÏ¿© ÀÓÇöõÆ® ¼ö¼ú¿ë ÅÛÇø´À» Á¦ÀÛÇÑ ´ÙÀ½, À̸¦ È°¿ëÇÏ¿© °èȹµÈ À§Ä¡¿¡ ÀÓÇöõÆ®¸¦ ½Ä¸³ÇÏ¿´´Ù. °ñÀ¯ÂøÀ» À§ÇÑ ÃæºÐÇÑ Ä¡À¯±â°£À» °¡Áø ´ÙÀ½ Áø´Ü ¿Î½º¾÷ ÇüÅ°¡ ¹Ý¿µµÈ ÀÓÇöõÆ® ÁöÁöÇü °íÁ¤¼º º¸Ã¶¹°À» Á¦ÀÛÇÏ¿´´Ù. ÃÖÁ¾ º¸Ã¶¹° ÀåÂø ÈÄ 6°³¿ù°£ÀÇ °æ°ú °üÂû ±â°£ µ¿¾È ½É¹ÌÀû, ±â´ÉÀûÀ¸·Î ¸¸Á·ÇÒ ¸¸ÇÑ Ä¡·á °á°ú¸¦ º¸¿´±â¿¡ À̸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Å°¿öµå

ÀÓÇöõÆ®; Áø´Ü ¿Î½º¾÷; ¸ÂÃãÇü ÀΰøÄ¡; µðÁöÅÐ º¹Á¦ ±â¼ú
Dental implant; Diagnostic wax up; Customized artificial tooth; Digital duplication technique

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

  

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed